Download presentation
Presentation is loading. Please wait.
Published byCalvin Gilmore Modified over 9 years ago
1
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Learning-based Component for Suppression of Rectal Tube False Positives: Evaluation of Performance on 780 CTC Cases S Lakare, A Barbu, M Dundar, M Wolf, L Bogoni, D Comaniciu Computer-Aided Detection and Knowledge Solutions Siemens Medical Solutions USA, Inc.
2
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Page 2 Motivation Removing CAD marks on Rectal Tubes can decrease reviewing time spent on obvious false positives Fewer obvious false positive marks can increase radiologists’ confidence of the CAD system
3
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Page 3 Marks on Rectal Tubes Rectal tubes can have a bumpy, polyp-like shape A CAD system can detect those bumps – resulting in false-positives (FPs)
4
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Page 4 Overview – Rectal Tube Detection Module 3D circles Short tubes Segmented tube Input volumeOutput
5
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Page 5 3D Circle Detection 3D curvature, gradient and data based features 12 circles (4 radii x 3 relative positions) relative to the circle of interest 8 types of statistics (mean, variance, percentiles, etc) in total 6720 features 15,000 positive samples 207,000 negative samples Detection Rate: 95.6%
6
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Page 6 Short Tube Detection Short tubes are constructed from pairs of 3D circles of well aligned tubes 13,700 positive samples 400,000 negative samples Detection Rate: 95.1% The tubes are then connected by dynamic programming The parameters of a short tube A short tube is constructed from a pair of 3D circles
7
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Page 7 Training Data Cases with clean prep 234 volumes 8 sites Siemens, GE, Toshiba MDCT 4, 16 and 64 slice scanners Cases with tagged prep (combinations of iodine & barium) 154 volumes 4 sites Siemens and GE MDCT 16 and 64 slice scanners Rectal Tubes are annotated and then used for training
8
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Page 8 Results – Standalone System Tested on 210 unseen cases Detection Rate: 94.7% 26 false positives 0.12 FP/vol Running time was 5.3 seconds/volume None of the 26 false alarms was a polyp
9
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Page 9 Detection Results
10
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Page 10 False Positives
11
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Page 11 Integration into CAD Prototype* Input Data Candidate Generation Feature Computation ClassificationCAD marks * Work in Progress, not available commercially
12
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Page 12 Integration into CAD Prototype Input Data Candidate Generation Feature Computation Classification CAD marksRectal Tube Detection
13
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Page 13 Test Data Cases with clean prep 405 cases, 783 volumes 10 sites Siemens, GE, Toshiba MDCT 4, 16 and 64 slice scanners Cases with tagged prep (combinations of iodine & barium) 373 cases, 587 volumes 4 sites Siemens and GE MDCT 16 and 64 slice scanners
14
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Page 14 Integrated Results – CG Stage Input Data Candidate Generation CAD marksRectal Tube Detection
15
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Page 15 Integrated Results – CG Stage Clean cases 257/405 had candidates on rectal tube (351/783 volumes) Candidates/patient count reduced by 2.92 Candidates/volume count reduced by 2.04 Tagged cases All volumes had candidates on rectal tube Candidates/patient count reduced by 2.56 Candidates/volume count reduced by 1.70
16
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Page 16 Integrated Results – Overall Input Data Candidate Generation Feature Computation Classification CAD marksRectal Tube Detection
17
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Page 17 Integrated Results – Overall Clean cases Candidates/patient count reduced by 0.30 (8%) Candidates/volume count reduced by 0.20 (10%) Tagged cases Candidates/patient count reduced by 0.15 (3%) Candidates/volume count reduced by 0.09 (3%)
18
Copyright © 2006 Siemens Medical Solutions USA, Inc. All rights reserved. Page 18 Conclusion Presented a Rectal Tube detection method CAD marks on rectal tubes are suppressed Reduction in false positives Can potentially reduce interpretation time for Radiologists The system does not miss any additional polyps
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.