Download presentation
Presentation is loading. Please wait.
Published byJanel Singleton Modified over 8 years ago
1
Newer Methods in FP Dr. Anne Burke, MD, MPH Associate Professor, Gynecology and Obstetrics/ Population, Family, Reproductive Health Medical Advisor, Gates Institute Johns Hopkins University (with thanks to Jeff Spieler, USAID)
2
Priorities in Contraceptive Technology Expand access to, and availability of, EXISTING contraceptive methods (public and private sectors) Make existing methods EASIER, CHEAPER, BETTER Develop TOTALLY NEW TECHNOLOGY that can address unmet needs
4
Long-Acting Reversible Contraception
5
Intrauterine Contraception Copper T 380A IUD Copper ions Approved for 10 years use LNG IUS 20 mcg levonorgestrel/day Approved for 5 years use
6
IUDs: Mechanism Mechanism: primarily by preventing fertilization Copper has direct effects on uterus, sperm and ova Levonorgestrel: THICKENS cervical mucus THINS endometrial lining
7
The levonorgestrel intrauterine system
8
Change in hemoglobin during 5 years of use
9
Can IUD be used in: Adolescents? Nulliparous women? Women with previous pelvic infection? Women with HIV?
10
Can IUD be used in: Adolescents? Nulliparous women? Women with previous pelvic infection? Women with HIV? YES!
11
Newly approved IUD “Skyla ®” A little smaller A little less hormone 3 years
12
Implanon/Nexplanon™ Etonogestrel Implants Progestin-only method 4 x 0.2cm Prevents ovulation Long-acting (3 years) Main side-effect is unpredictable menstrual cycles Fertility returns within a few days of removal Highly effective
13
Other implantable contraceptives Jadelle, Sinoplant 2-rod implant (levonorgestrel)
14
Zarin® (Sino-implant II) Subdermal Contraceptive Implant
15
Comparison of Hormonal Implants 1 FOB price in country of origin. JadelleImplanonSino-implant (II)/Zarin ManufacturerBayer HealthcareMerck/MSDShanghai Dahua Pharmaceutical Ltd. Formulation150 mg levonorgestrel in 2 rods 68 mg etonogestrel in 1 rod 150 mg levonorgestrel in 2 rods Mean Insertion & Removal time Insertion: 2 min Removal: 5 min Insertion: 1 min Removal: 2-3 min Insertion: 2 min Removal: 5 min Labeled duration5 years3 years4 years TrocarsAutoclavable and Disposable Pre-loaded disposableDisposable Cost of implant (US$) 1 $8.50 ( $19.00)$16.40 ( $18.00)$8.50 Cost per Year (if used for duration) $1.70$5.50$2.13 WHO PrequalYes Application submitted
16
Characteristics of LARC Immediately effective HIGHLY effective Safe Rapid return of fertility after removal
17
75% Peipert Obste Gynecol 2012
18
Review of Safety of Postpartum IUD Cochrane database review, 2003 Main results Immediate post-partum insertion of IUDs appeared safe and effective. Few contraindications to method. Expulsion rates appear to be higher than with interval insertion. Feasibility supported by PPIUD insertion popularity in countries as diverse as China, Mexico, and Egypt. Early follow-up (6 weeks) may be important in identifying spontaneous IUD expulsions. Grimes D, Schulz K, van Vliet H, Stanwood N. Immediate post- partum insertion of intrauterine devices. The Cochrane Database of Systematic Reviews 2003, Issue 1
19
Postplacental IUD 6.9% 12.0% p<0.001 Chi Contraception 1985; slides c/o PSI Blumenthal % of women experiencing expulsion/6 months P <0.001
20
How do you do it? Postplacental IUD Insertion 2 1
21
Vaginal Rings
22
Nestorone® / Ethinyl Estradiol 1-Year Ring (CVR) 8.4 mm (3/8”) in cross section 58 mm (2 1/4”) in diameter NES Core NES / EE Core *Delivers NES/EE 150/15µg /day, 13 cycles 3 weeks on followed by 1 week off Developed by the Population Council Sponsored by USAID, NICHD, WHO
23
Most trial participants were satisfied, found the CVR easy to use, would pay for it if available, recommend it to friends, and preferred it to other methods they have used (Results: N=861)
24
Acceptability & Pregnancies: Adherence (T2)
25
Injectables Advantages: Length of action Safety TASK-SHIFTING OPPORTUNITY Disadvantages: Continuation Side effects
26
DepoProvera®: Medroxyprogesterone acetate Given every 3 months Mechanism: Suppresses ovulation Thickens cervical mucus Thins endometrium Intramuscular injection
27
New formulation of Depo-Provera: Depo-subQ Provera 104, for delivery with Uniject Depo-subQ Provera 104: New formulation for subQ injection 30% lower dose (104 mg vs. 150 mg) Rapid onset of action Same effectiveness, same length of protection (>3 months)
28
The LD Formulation of Depo-Provera Is Efficacious at Lower Peak Concentrations Pharmacokinetic Profiles of the LD Formulation of Depo-Provera and Depo-Provera Contraceptive Injection 4.0 3.0 2.0 1.0 0 50100150 200 0 Depo-Provera (n=8) LD Formulation of Depo-Provera (n=42) Time (days) MPA Serum Concentration (ng/mL) Data on file. LD = lower dose.
29
New formulation of Depo-Provera: Depo-subQ Provera 104, for delivery with Uniject Uniject (Sayana Press): Single dose, single package Prefilled, sterile, non-reusable Short needles for subQ injection (easier use by non-clinical personnel/CHWs) Compact; easy to use and store Potential for home- and self-injection Approval by EMA and LDC registration forthcoming
30
Emergency Contraceptive Pills SAFE Mechanism: Primarily by delaying/ preventing ovulation Does not cause abortion Many brands available worldwide Repeated use is safe Less effective than “planned” BC Trussell J, Jordan B. Contraception. 2006
31
Pregnancy rates after levonorgestrel EC were 1.5 – 3% EC can be taken up to 72 (or 120) hours after intercourse, but effectiveness decreases with time. WHY? Related to mechanism of action… Sperm can survive for several days
32
Chance of pregnancy with intercourse, compared to timing of ovulation Source: Wilcox, 2001
33
Ulipristal for EC Antiprogestin, similar to mifepristone Dose = 30mg Blocks ovulation May also have endometrial effects Does not cause abortion More effective than LNG for EC Does not lose effectiveness with delay Lower pregnancy rates in the studies
34
Obesity and ECP: Emerging data Failure rates higher for LNG among obese women, compared to non-obese Ulipristal: not as alarming a difference Questions: where has this data been? What do we tell clients?
35
Underutilized: Copper IUD for EC When in the cycle? *(Off-label use) Turok D et al. Hum. Reprod. 2013;28:2672-2676
36
Copper IUD for EC Can be inserted within 5 days of intercourse. When the day of ovulation can be estimated, the copper IUD also can be inserted more than 5 days after intercourse, up to 5 days after ovulation Safe for vast majority of women Efficacy preserved at high BMI EXCELLENT continuing contraception
37
SILCS Diaphragm: “One size fits most” Firm insertion edge w/ soft spring in rim for improved comfort Grip dimples and easy insertion Cervical cup membrane Fingertip dome for easy removal Side view Top view Silocone rather than latex Appropriate for OTC use No pelvic exam or fitting required US CT completed in 2010 USFDA approval in 2012
38
Woman’s Condom Easy to handle/use, insert and remove Stable during use Comfortable for both partners Less expensive than current options
39
Product Features Manufactured by Dahua (China – not same company as for SI-II) U.S. clinical trials (2011- 2012) will lead to FDA product registration – estimated for 2013 CE Mark application planned for 2011
40
New Contraceptive Methods Needed 1.Non-hormonal, non-steroidal or non-estrogen or novel progestin-only oral contraceptives 2.Biodegradable progestin-only implants (APS) 3.Non-surgical methods of male and female sterilization 4.Novel multi-purpose/dual protection methods (APS) 5.Peri-coital contraception
41
Spermicides – works in progress Highly effective? No vaginal irritation? Trials ongoing
42
Amphora Gel (Evofem) Water-based gel Acidiform Hormone-free Trials ongoing
43
“On demand” products: Used before/after intercourse Appropriate for women who have infrequent sex, or who would like more direct control over their own protection Priorities for product R&D: Other MPT-related activities: Clarifying the Regulatory Approval of MPTs Review existing guidance on combination products from Regulatory Authorities (RAs) Convene technical meetings with RAs and WHO to discuss approval pathways for MPTs Initiative for MPTs Expand international awareness and support for MPTs Convene technical meetings to advance late-stage product development and introduction Sustained release devices: User-initiated, but do not require daily action Should increase acceptability and adherence, and therefore overall effectiveness USAID support for MPTs
44
Prevent unintended pregnancy Protect against HIV, other STIs & RTIs Provide additional health benefits Our Ultimate Goal: An expanded range of Effective Acceptable Accessible prevention options that address the sexual and reproductive health concerns of women as they change over time. Aim: develop multipurpose prevention options that…
45
Sustained-Release Combination Intravaginal Rings (IVRs) 90-day TFV + LNG IVR (CONRAD) Combines the hormonal contraceptive LNG with TFV in a polyurethane IVR Clinical studies of TFV+LNG ring to begin 2012 60-day Dapivirine + Contraceptive IVR (IPM) Combines a hormonal contraceptive (tbd) with dapivirine in a vaginal ring (material tbd) Formulation work is underway The dapivirine-only ring will begin Phase III efficacy testing for HIV prevention in mid-2012 MPT development activities, Part II
46
TFV/Levonorgestrel (LNG) IVR: Segmented Reservoir Design Builds on the TFV-only reservoir IVR design Segmented approach allows for independent optimization of each drug’s delivery needs LNG release rate is controlled by: Rate-controlling membrane (thickness and diffusivity) Length of the LNG segment TFV LNG
47
TFV/LNG IVR: Product Design Objectives Release Rates: TFV: 10 mg/d LNG: 10 or 20 µg/d Duration: 90 days Dimensions/Mechanic al properties: Same as TFV IVR, similar to NuvaRing® 20 mm LNG segment 10 mm LNG segment
48
MZL Combination Topical Gel (Population Council) Combines MIV-150 + Zinc Acetate + the progestin LNG in carrageenan gel Prevents pregnancy, HIV, HSV-2 and HPV (based on in vivo studies) Provides effective protection for up to 24 hours Gel optimization and initial PK in vivo is underway SILCS Diaphragm + Tenofovir (TFV) Gel (CONRAD) Use the SILCS diaphragm as a delivery device for TFV gel, reformulated to enhance contraceptive activity TFV gel is the only topical ARV shown thus far to be effective in preventing HIV (39%) and HSV-2 (51%) Combination would provide a non- hormonal method to prevent unintended pregnancy, HIV and HSV-2 Designed for effective protection for up to 24 hours TFV gel reformulation to begin in early 2012 “On Demand” Barriers and Gels MPT development activities, Part I:
49
SILCS/Contraceptive TFV Gel Work funded by USAID #APS-OAA-10-000003: Fast- track Late-stage Development of MPTs Objectives: 1. Develop the combination of SILCS diaphragm with TFV gel as a MPT with the potential to address multiple indications: Contraception HIV prevention HSV prevention 2. Reformulate the TFV gel to enhance contraceptive efficacy
50
These MPT products in development could simultaneously prevent pregnancy, HIV, HSV-2, and HPV. KEY Diversifying delivery & dosing options is KEY to meeting the different needs of women, and thereby expanding acceptability and use: MZL gel: ideal method for women who would like a product they could use “on demand”, and that lasts up to 24 hours SILCS+TFV gel: ideal method for women who would like a non-hormonal contraceptive product that they control, especially for intermittent sex Combination IVR (TFV+LNG or DAP+HC): ideal method for women who would like a highly effective product that requires minimal user involvement, and that provides continuous protection for 1-3 months Our Aim: Expand the range of safe, effective and acceptable prevention options that meet different needs, and are appropriate for delivery and use in low resource settings Conclusion: first-generation MPTs
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.