Presentation is loading. Please wait.

Presentation is loading. Please wait.

2011 Users Conference Nashville, TN.

Similar presentations


Presentation on theme: "2011 Users Conference Nashville, TN."— Presentation transcript:

1 2011 Users Conference Nashville, TN

2 Distribution Automation
Product Line Overview

3 Topics Role of DA in Sensus Product Portfolio Sensus DA Endpoints
RTM II T866 TC032 NaviComm Software – PowerVista, SCADA-Xchange Application Matrices Product Roadmap

4 Sensus Solution Architecture
Metrology Electric Water Gas Head End Software Communications Infrastructure Home Area Networking and Load Control Modules Distribution Automation

5 Sensus Distribution Automation
Distribution Automation (DA): Provides head end system and endpoints that enable a utility to remotely monitor, coordinate, and operate automation components in a real-time mode from remote locations. DA Endpoints monitor/control field equipment Information is reported to Host System using FlexNet or Cellular radios Information is made available to utility user via a DA head end system or through the utility’s SCADA system Commands/Requests can be sent at any time to the Endpoints Interfaces to any 3rd party intelligent electronic devices that communicate via DNP3 or Modbus

6 DA Endpoints Sensus DA products support a wide variety of automation applications Endpoints supported by PowerVista DA head end software Both FlexNet and Cellular versions available RTM II – Intelligent Electronic Device Communications Module T866 - MicroRTU NaviComm – Fault Current Indicator Receiver TC032 – Capacitor Bank Control They can send data and event notifications over a private, secure FlexNet system or by using existing cellular systems. PowerVista provides the communication network to detect, monitor, control, and make changes to the system remotely.

7 DA End-to-End System DA Endpoints
Sensus Communications and DA Head End IED PowerVista Utility Users DA Database RNI – Regional Network Interface Towers and FlexNet Base Stations RTM II interface to IEDs, NaviComm, T866, TC032 SCADA-Xchange SCADA

8 RTM II Overview Remote Telemetry Module for interfacing to Intelligent Electronic Devices Communication protocols: DNP 3.0/IEEE 1815 Modbus Radios: FlexNet, Cellular GSM, CDMA in development Remote Firmware Update/Tunneling Capability Three reporting methods: Report by Exception Time Scheduled Response to Report Requests IED Port Pass Thru Port IED Terminal PC Port DC Power BOTTOM

9 RTM Interface Example RTM II mounted on inside of cabinet
RTM II power shares IED DC supply SCADA connection for data monitoring and remote switch control Pass Through for device configuration program RTM II DA Device Controller Direct Pass Through SCADA Connection

10 Cooper Form 6 Recloser Control
RTM II – How It Works Programmed with a profile detailing the relevant points on the IED as well as how the user wants the data to be reported. Constantly polls the IED to get the latest data. When it discovers a reportable event, it initiates a report over the radio network to the DA head end The data is validated, acknowledged, and processed for distribution to the end user. Control and configuration information can be sent from the end user back to the IED as well. RTM II NOC Cooper Form 6 Recloser Control SEL651 Recloser Control End User IEDs

11 DA Configurator Software
Sensus DA Configuration software is used to: Change configuration settings Retrieve and view the present profile Choose a different profile Change communication settings Check radio signal strength Update firmware The software includes default profiles for each supported integration. Use a standard USB cable to connect the RTM II and the PC containing the DA Configuration software.

12 Example RTM II Configuration Screen

13 Recloser/Switch Control Case Study
1000+ devices DNP-RTM & MicroRTU Cooper 4C, F6 & ABB PCD 2000, Cleaveland Price SCADA-Xchange Benefits Reduced SAIDI/MAIFI/CAIDI Provides valuable data for planning and asset management Reduced O&M cost Support DNP & 2179 protocols

14 T866 MicroRTU Overview Remote digital and analog monitoring and control Features: 8 Digital Inputs 6 Digital Outputs 6 Analog Inputs (includes 2 AC detect) Reports any momentary or continuing changes Communication initiated by: Automatic report upon status change Time scheduled in advance User-initiated report requests Confidential

15 T866 MicroRTU Applications
A multi-channel I/O device suitable for general purpose usage in a wide variety of applications such as: Electric circuit switch retrofit and control Water and wastewater monitoring Environmental monitoring Distributed generator control Irrigation control Designed for indoor or outdoor environments Dual power supply can operate from AC or optional DC power sources Internal radio provides two-way communications to the PowerVista™ application suite

16 T866 Configuration Screen
Options Signal Type Scaling Control Setup Some reporting triggers

17 Water Control Case Study

18 Event Based Actions Event Based Action Rules for Pump Control set up in PowerVista

19 NaviComm Overview Self-Contained fault current indicator (FCI) receiver for PDP Smart Navigators Speeds up crew response for overhead circuit fault location Monitor up to12 FCIs Reports Fault magnitude Fault duration Load current Peak Load Current Provides data to utility SCADA via DNP3 Smart Navigator FCIs NaviComm

20 NaviComm Installation
NaviComm mounted on pole with connection to control power. PDP Smart Navigator fault current indicators mounted on overhead conductors.

21 TC032 Capacitor Control Overview
Cost effective solution for monitoring and control of switched and fixed capacitor banks Local voltage and temperature switching strategies Integrated communications Neutral current monitoring option Interface to either SCADA or Volt/VAR applications via SCADA-Xchange

22 Capacitor Control Case Study
TC032 Capacitor Control Voltage/Temperature based control Remote monitoring and operation capability Neutral current monitoring for bank failure Benefits Improved reliability Central control when required Reduced O&M expenses Deferred capital expenditures Eliminated manual switching of seasonal banks Better asset management

23 PowerVista The DA Head End software suite!
A Web-based application that provides tools to: Interface to DA Endpoints Monitor communications status Device alarms and off-normal reporting Manage user accounts and access Can be hosted or deployed as an onsite solution. Device List Page

24 T866 Point View Example View Status of: Digital Inputs Analog Inputs
Digital Outputs Change Status (if user authorized) Can also set up alarms and user notifications based on changes in status

25 DA Remote Telemetry Interface
SCADA-Xchange Economical means of integrating Sensus’ control and data acquisition functionality with utility SCADA. SCADA- Xchange server appears as DNP3 compliant virtual RTU to utility SCADA client. Utility IT Systems SCADA DA Head-End PowerVista with SCADA -Xchange Base Stations Secure Network Secure Backhaul Two-Way Radio Intelligent Electronic Device DA Remote Telemetry Module DA Remote Telemetry Interface DNP 3.0 DNP 3.0 Encapsulated into Data Packets DNP 3.0 Encapsulated into TCP/IP

26 Electric DA Application Matrix
Description Sensus DA Products Recloser/Switch Monitoring and Control Recloser/Switch status, remote recloser operation, DNP3 link for SCADA RTM with kits/profiles available for common controllers Capacitor Bank Monitoring and Control Capacitor status , remote operation for volt/var control, DNP3 link for SCADA Capacitor bank controller with embedded communications and neutral current monitoring TC032 capacitor control Voltage Regulation and Voltage Power Quality Voltage regulator status and control, DNP3 link for SCADA Pad Mount Switchgear Automation Upgrades Remote operation of motor-controlled switch MicroRTU Remote access to switch intelligent controller RTM Fault indication to improve reliability or automated switching schemes MicroRTU with fault sensors Fault Indicators Overhead line fault indication and load monitoring NaviComm Underground fault indication MicroRTU interface for fault indicators

27 Water Automation Application Matrix
Monitor Control Product Tank/Reservoir Level Monitor with Control Level Pressure AC Power to pump Pump (may be separate or multiple) T866 MicroRTU Pump Monitor and Control Flow AC Power Motorized valves Lift Station Monitoring and Control Level or level alarm Meter SCADA RTU + RTM Modbus Remote PLC Various analog, digital points Various control outputs RTM Modbus

28 DA Product Roadmap (1) RTM II+ PowerVista 3.x
Addition of Ethernet Port FlexNet IP Support 3G Cellular IP PowerVista 3.x Improved user interface and report generation RTM Ethernet and IP support Remote endpoint configuration Reduced latency and improved data compression Water Automation Applications

29 DA Product Roadmap (2) DA/AMI Convergence – Bellwether Meters for Volt/VAR Control Bellwether voltage samples on dedicated FlexNet channel. Bellwether meters user configurable for predefined report intervals (ex. 5 minutes). Data routed via AMI head end to Volt/VAR control application.

30 QUESTIONS?


Download ppt "2011 Users Conference Nashville, TN."

Similar presentations