Who is T&T Power Group? T&T Power Group stems from humble roots in the service sector providing generator maintenance and emergency response service to local customers. From here we have grown to a company with the same core values, but a larger servicing area, and a wider range of products and product support for our customers. We services thousands of generators across Canada in all major sectors. We understand the importance of service and sales, and our differing departments work cohesively to serve a common goal; the satisfied consumer. We provide temporary power systems in the events of failure, and 24/7 emergency response to all customers. Our capabilities are unlimited when it comes to the manufacture, sales, and service of your power generation equipment, and we look forward to working with you on your next project.
8
What can We do for You? Generator Design Generator Build Generator Servicing Generator Rentals
9
Why are We Here Today? Generator Design Generator Build Generator Servicing Generator Rentals
10
Questions? Please feel free to ask questions throughout, or bring them up at the end of this presentation.
11
Service Capabilities 24/7/365 EMERGENCY SERVICE EGSA CERTIFIED TECHNICIANS LICENSED MECHANICS LICENSED ELECTRICIANS TECHNICAL SUPPORT COMPLETE CSA 282 PREVENTATIVE MAINTENANCE PROGRAMS
12
CSA 282 MAINTENANCE C282-09: Emergency electrical power supply for buildings Scope: This Standard applies to the design, installation, operation, maintenance, and testing of emergency generators and associated equipment for providing an emergency power supply to electrical loads
13
CSA 282 MAINTENANCE
15
ANNUAL REQUIREMENTS
16
CSA 282 MAINTENANCE ANNUAL REQUIREMENTS
17
CSA 282 MAINTENANCE ANNUAL REQUIREMENTS
18
CSA 282 MAINTENANCE ANNUAL REQUIREMENTS
19
CSA 282 MAINTENANCE LOAD BANK TESTING (part of C282 Annual Maintenance and Testing Requirements)
20
CSA 282 MAINTENANCE LOAD BANK TESTING (part of C282 Annual Maintenance and Testing Requirements) Benefits of Load Testing: Uncovers issues so that they may be dealt with preventatively Exhaust Deposits are burned off and cleaned out Assess Functionality and Durability
21
CSA 282 MAINTENANCE Documentation Requirements: C282 Log Book Must Be Completed – Record all weekly, monthly, semi-annual and annual inspections (T&T can provide) Annual Load Bank Testing Report Annual Inspection Reports to be available upon request (filed electronically and hard copy stored in the generator room)
22
OTHER CODE REQUIREMENTS CSA Standard B139, Installation Code for Oil- Burning Equipment This Code was developed in cooperation with the Canadian Standards Association, publishers of CAN/CSAB139. Storage tank systems that fall within the scope of CAN/CSA B139 are predominantly furnace oil tanks and storage tanks containing diesel fuel and connected to standby emergency power generators.
23
OTHER CODE REQUIREMENTS NFPA 110 NFPA 110 provides performance requirements for emergency and standby power systems to provide reliable auxiliary power to supply critical and essential needs during outages of the primary power source. This Standard covers installation, maintenance, operation, and testing requirements as they pertain to the performance of the emergency power supply system, including power sources, transfer equipment, controls, supervisory equipment, and all related electrical and mechanical auxiliary and accessory equipment.
24
MANUFACTURING CAPABILITIES T&T POWER GROUP’S STANDARD MODELS: 10KW – 600KW Diesel Gensets 30KW – 400KW Natural Gas Gensets Custom Packages to Suit ALL Requirements
25
MANUFACTURING CAPABILITIES T&T POWER GROUP’S STANDARD MODELS: 10KW – 600KW Diesel Gensets 20KW Generator Commonly used for small office buildings or telecommunications towers:
26
MANUFACTURING CAPABILITIES 600KW 600V Commonly used for large pumping stations and water treatment plants
27
MANUFACTURING CAPABILITIES T&T POWER GROUP’S STANDARD MODELS: 30KW – 400KW Natural Gas Gensets
28
MANUFACTURING CAPABILITIES 400KW Natural Gas Generator, used in prime power applications:
29
MANUFACTURING CAPABILITIES 400KW Natural Gas Generator, used in prime power applications:
30
MANUFACTURING CAPABILITIES Custom Packages to Suit ALL Requirements
32
MANUFACTURING CAPABILITIES Custom Packages to Suit ALL Requirements 2.2 Mega Watt 600V Power Generation Package Consisting of Four 550KW Diesel Generators Synchronized Together Offers: - Redundancy - Fuel savings for non-peak loads - Zero down time in the case of mechanical failure - More economical capital expense and repair costs
33
RENTAL CAPABILITIES Rentals Available to Suit All Requirements Rentals available 24/7/365 to cover you in the case of a power outage or generator failure
34
RENTAL CAPABILITIES Rentals Available to Suit All Requirements Rentals as small as 10KW and as large as 2MW!
35
Let’s get back to servicing So you’ve seen that we can build
36
Let’s get back to servicing So you’ve seen that we can build You’ve seen that we have rentals
37
Let’s get back to servicing So you’ve seen that we can build You’ve seen that we have rentals So what can we service??
38
Let’s get back to servicing So you’ve seen that we can build You’ve seen that we have rentals So what can we service?? All makes of GENERATORS and TRANSFER SWITCHES
39
BRANDS WE COMMONLY SERVICE:
41
Let’s touch on this one really quick...
42
You NEED to have properly trained technicians and experienced generator companies work on your equipment! Make sure you ask your service company if they are an EGSA member.
43
IS your equipment being properly maintained?? You’ve made the investment in your emergency standby generator. Make sure your investment is going to be there when you need it most.
44
Oil System failure This is an Oil pan is from an Engine that has had a catastrophic failure. The Generator was not serviced on a regular program with no oil change for many years. This is just an example of what can happen with no maintenance program. Let us design and implement a program specific to your needs.
45
Cooling System failure Think of this as “The other life blood” of your engine Should be tested annually Must be replaced every 5 years Use proper coolant for engine type
46
Cooling System failure
47
Ten Common Reasons Why Your Power System May Leave You In the Dark. 1)BATTERY SYSTEM FAILURE 2)CONTROL SYSTEM ISSUES 3)COOLING SYSTEM PROBLEMS 4)FUEL SYSTEM PROBLEMS 5)AUTOMATIC TRANSFER SWITCH (ATS) OR SWITCHGEAR ISSUES 6)CIRCUIT BREAKER PROBLEMS 7)INTAKE/EXHAUST VALVE PROBLEMS 8)GENERATOR WINDING ISSUES 9)LUBRICATION PROBLEMS 10)WET STACKING AND CARBON BUILD UP
48
ALL OF THESE PROBLEMS ARE EASILY AVOIDED WITH PROPER MAINTENANCE! 1)BATTERY SYSTEM FAILURE 2)CONTROL SYSTEM ISSUES 3)COOLING SYSTEM PROBLEMS 4)FUEL SYSTEM PROBLEMS 5)AUTOMATIC TRANSFER SWITCH (ATS) OR SWITCHGEAR ISSUES 6)CIRCUIT BREAKER PROBLEMS 7)INTAKE/EXHAUST VALVE PROBLEMS 8)GENERATOR WINDING ISSUES 9)LUBRICATION PROBLEMS 10)WET STACKING AND CARBON BUILD UP
49
How do you make sure your equipment is being properly maintained? Follow the CSA 282 guidelines Have properly trained personnel performing the maintenance. Change engine oil at least every 12 months Monitor and test cooling system annual.
50
Questions?
51
Thank you for your time. Please visit our website to learn more about our products and services. www.ttpowergroup.com