OP – Workshop 2014 BI-SIS18 Piotr Kowina für LOBI - Abteilung aufbereitet für Operating ckw
2
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 Outline 2 New position of several Beam Instrumentation (BI) components within SIS18 Lattice New BI electronics NEW DAQ New Software Beam Instrumentation is not only hardware and software – it is also an INTERPRETATION and UNDERSTANDING: new ways of data analysis and extraction of beam parameter Wahl der Mittel Kombination der Diagnostik für korrektes Einstellung Erarbeiten von routine Einstellprozeduren bei verschiedenen Strahlen
3
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 Diagnosequipment 3 S09 DT_ML alter standard Trafo Radio schmalband Intensitätsmonitoring S09 DT_S schneller Trafo für Injektion S01 DT_ML hochstromfester Trafo von Bergoz S01 DT_FP schneller Trafo von Bergoz ( FTC ) S12 DG first Turn Gitter S12 DP_X Sonden mit großer Bandbreite in 50 Ohm S03 DI PH/V Restgasmonitor (IPM) Sxx DX Positionsonden TOPOS Schmalbandmessung im ELR (Analogsignal) S01 BO_x BTF TOPOS Schottky Energiematching etc. S06 DF Ausschussleuchtarget TE1 DT1 Trafo schnelle Extraktion ABLASS Verlustmonitor Vacuum Druckmessung
4
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 Loaded current transformer I sec = 1/N · I beam Inductance of a torus of μ r Goal of Torus: Large inductance L and guiding of field lines. Definition: U = L · dI/dt 4 Beam Current Measurement using Transformer Beam current of N charges with velocity cylindrical symmetry → only azimuthal component Example: 1 μA, r = 10cm 2 pT, earth B = 50 T Idea: Beam as primary winding and sense by sec. winding. I beam v out R Torus to guide the magnetic field A voltages is measured: U = R · I sec = R /N · I beam ≡ S · I beam with S sensitivity [V/A], equivalent to transfer function or transfer impedance Z
5
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 5 5 The DC Transformer Modulation without beam: typically about 1 kHz to saturation → no net flux Modulation with beam: saturation is reached at different times, → net flux Net flux: double frequency than modulation Feedback: Current fed to compensation winding for larger sensitivity Two magnetic cores: Must be very similar.
6
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 6 Specification of Bergoz type DCCT: 6 S07 DT_ML and DT_FP Transformers -> Sector S01
7
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 New DAQ for FCT 7 Fast Current Transformer (FCT) has extremely wide bandwidth 9 kHz < f < 650 MHz 50 Windings resolution 1V/A in 50 Ohm ~30 μA for FCT with 500 MHz bandwidth upper pulse current limit 1000 A max. rms current 25 A FCT installed in same shield as DCCT DCCT Exemplary realization at GSI FCT signal was amplified by 20 dB (miteq AM-1422) and digitized a 500 Ms/s ADC via ~100m HQ coax cable
8
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 8 Ref.: O. Chorniy (BI) GSI Darmstadt Longitudinal signal from Capacitive Pickup Longitudinal signal from Fast Current Transformer Capacitive Pickup Vs. FCT For longitudinal diagnostics use FCT – it has much better resolution!
9
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 Longitudinal Bunch Diagnostics using FCT 9 Exemplary observation of RF capture over the full acceleration cycle at GSI SIS18 Synchrotron
10
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 Longitudinal Bunch Diagnostics using FCT 10 4:2:1 Bunch Merging at SIS18 Synchrotron H. Klingbeil, U. Hartel, et al. (GSI/RF) Cycle time
11
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 RF Capture at Different Beam Intensities 11 Measurement at GSI SIS18 Synchrotron Main beam parameters: Ion type: Ar 18+ Energy: 11.4 MeV/u RF ramping time: 3 ms O. Chorniy (GSI/BI)
12
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 RF Capture at Different RF Ramp 12 GSI SIS18 Synchrotron, Ar 18+, constant energy 11.4 MeV /u, Ion Intensity 2x10 10 part/cycle fast RF capture (1 ms) slow RF capture (20 ms) O. Chorniy (GSI/BI)
13
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 13 NEW IPM installed in S03
14
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 14 IPM: Magnet Design for SIS18 Design by G. de Villiers (iThemba Lab), T. Giacomini (GSI) Maximum image distortion: 5% of beam width B/B < 1 % Challenges: High B-field homogeneity of 1% Clearance up to 500 mm Correctors required to compensate beam steering Insertion length 2.5 m incl. correctors read-out on 1 s turn-by-turn scale by multi-anode photo-multiplier Magnetic field for electron guidance: Corrector 480mm Corrector Horizontal IPM Vertical IPM Insertion length 2.5 m 300mm Compensation scheme:
15
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 Ionization Profile Monitor: Principle 15 Advantage: ‘4 -detection scheme’ for ionization products Detection scheme: Secondary e - or ions accelerated by E-field electrodes & side strips E 50… 300 kV/m MCP (Micro Channel Plate) electron converter & 10 6 -fold amplifier either wire array down to mm pitch high time resolution or Phosphor screen & CCD high spatial resolution of 100 m Signal strength scales with energy-loss dE/ dx 1/E for SIS parameters CCD Phosphor MCP 2 MCP 1 Light Electrons Channels 10 m Residual gas ion Ion beam
16
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 Signal Strength for IPM Target electron density: Proportional to vacuum pressure 1/E kin (for E kin > 1GeV nearly constant) Strong dependence on projectile charge for ions A Zp Physics: Energy loss of hadrons in gas dE/dx Profile determination from residual gas Ionization: about 100 eV/ionization pc [GeV] Proton energy loss in 10 -7 mbar N 2 using SRIM ion source LINAC, cyclotron synchrotron Ionization probability proportional to dE/dx by Bethe-Bloch formula: 16
17
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 17 Example: U 73+ beam at GSI for intensity increase s tacking by electron cooling and acc. 11.4 400 MeV/u IPM: Observation of Cooling and Stacking Task for IPM: Observation of cooling Emittance evaluation during cycle | 5 injections + cooling | | acc. | horizontal IPM: Profile recording every 10 ms measurement within one cycle.
18
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 18 New BTF Exciter Old position of the Combined KO/BTF Exciter in Sector S07 New position of separated KO and BTF Exciters in Sector S01 KO-exciter (HOR) BTF-exciter (VER) BTF-exciter (HOR) KO and BTF exciters are now mechanically separated. Vertical part of KO-exciter was exchanged with new developed BTF exciter consisting of two separated parts for VER. and HOR plane. The length is the half of those for KO- exciters.
19
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 Tune and BTF Measurement 19 Generator spectrum (short region around expected tune is excited) Part of the GUI in GSI control room
20
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 20 New BTF Electronics Old 25 W amplifiers and control electronics installed in SIS18 tunnel New 50 W amplifiers in ELR 50 W BTF Amps. 25 W BTF Amps. 400 W KO Amp. (now moved to BG 16 [SIS-HF[ )
21
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 Tune Measurement 21 Generator spectrum (short region around expected tune is excited) 21 (HKR, Rack 74 & 75)
22
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 Tune Measurement Using Position Data 22 Hor. Ver. Hor. Ver. Tune (at given time) Beam Position Tune over the cycle Tune on the tune diagram TOPOS= Tune Orbit POsition System at GSI SIS18
23
OP – Workshop 2014 Schottkydiagnostik
24
OP – Workshop 2014 ABLASS
25
P. Kowina, Strahldiagnose-Umbauten OP – Workshop 2014 Strategien & Konzepte 25 S09 DT_ML alter standard Trafo Radio schmalband Intensitätsmonitoring S09 DT_S schneller Trafo für Injektion S01 DT_ML hochstromfester Trafo von Bergoz S01 DT_FP schneller Trafo von Bergoz ( FTC ) S12 DG first Turn Gitter S12 DP_X Sonden mit großer Bandbreite in 50 Ohm S03 DI PH/V Restgasmonitor (IPM) Sxx DX Positionsonden TOPOS Schmalbandmessung im ELR (Analogsignal) S01 BO_x BTF TOPOS Schottky Energiematching etc. S06 DF Ausschussleuchtarget TE1 DT1 Trafo schnelle Extraktion ABLASS Verlustmonitor Vacuum Druckmessung Lebensdauermessung
26
OP – Workshop 2014 Thank you for your attention