© 2014 Eaton Corporation. All rights reserved. EATON ePDU G3 (Generation 3) Third-generation ePDU technology for best-in-class power distribution May 2014.

Similar presentations


Presentation on theme: "© 2014 Eaton Corporation. All rights reserved. EATON ePDU G3 (Generation 3) Third-generation ePDU technology for best-in-class power distribution May 2014."— Presentation transcript:

1 © 2014 Eaton Corporation. All rights reserved. EATON ePDU G3 (Generation 3) Third-generation ePDU technology for best-in-class power distribution May 2014 Stefan Coote

2 2 2

3 3 3 Value Proposition Reliably distribute, accurately monitor and control the power consumption of your IT equipment See where you have available power and are most efficient Management software allows mass control, mass configuration and analysis, plus Hypervisor and UPS integration Integral part of Eaton’s Intelligent Power Pod Made in EMEA - fast shipping times Custom units available to meet your needs

4 4 4 Eaton ePDU G3 Levels of Technology G3 Platform is designed for Both Standard off-the-shelf models and Custom models Growing Functionality Q2 Q4/ 2015 Basic Basic Reliable Power Distribution Metered Outlet Metered Input In-Line Metered Metered Outlet Metered Input and Branch Circuit Add Metering to upgrade Basic PDUs Switched Switched Outlet + Metered Input Managed Switched Outlet + Metered Outlet

5 5 5 Prevent accidental disconnect  IEC Outlet eGrip Plug Retention Secures plugs in place with a lever activated grip integrated into each outlet Prevents accidental disconnect from being bumped or from rack vibration Eliminates bulky cable management bars that block airflow and decrease serviceability  Works with standard cables - No need for the customer to buy special cables

6 6 6 True IEC Class 1 Billing Grade Accuracy There is a demand for higher accuracy in department billing and colocation data centers To bill customers for energy used Closely monitor consumption Define racks and areas with available power Eaton ePDU G3 offers IEC Class 1 - Billing Grade Accuracy Available across whole technology range Increasing cost of power Increasing demand for power

7 7 7 Central Management of your ePDU Advanced LCD display with menu system Rotate display for top and bottom fed ePDU Read current, voltage, power, kWhr and more Change settings Optional Environmental monitoring probe Configuration and Upgrade Via USB stick configuration file En Masse via IPM software Daisy Chain capability

8 8 8 Reduce IP Ports  Daisy Chain 4 ePDUs Chain four ePDUs from one IP address and network port Manages power supplies on different feeds through one interface Reduces physical infrastructure installation costs by 75% Saves on CapEx and simplifies management Network switch 1 2 4 2 3 4

9 9 9 No Down Time On Updates  Hot-Swap eNMC eNMC module contains meter, network ports, LCD display and CPU Hot Swappable - No loss of power to IT equipment when replacing Firmware updates - with no loss of power to IT equipment Field serviceable with no down time

10 10 Doesn’t protrude into the rack – even at the breakers Width and height are optimized for multiple mounting options Design prevents interference with the rail - won’t block hot swap fans and power supplies Low-profile circuit breakers

11 11 Critical element – Low Profile Form Factor Standard chassis size 52mm wide, 53mm deep, 58.7mm at breakers All IEC units, all technologies Even for 32A 3 Phase Units Deep base chassis Switched and Managed ePDU G3 with National outlets and some custom units 52mm wide, 65mm high, 70.7mm at breakers

12 12 Easy Installation – Multiple Options as Standard Patented variable mounting brackets allow true mounting flexibility Mounting buttons are pre-installed to save installation time Button locations on the side to mount G3 at a 90- degree rotation in the rack Double-sided buttons accommodate variations of rack metal thickness

13 13 Raise or lower the ePDU in the rack Change the distance between mounts Easy Installation + Extremely flexible G3 Platform is designed to have the most flexible installation on the market

14 14 60˚ Operating Temperature  Can be used in very hot environments Basic and Metered Input G3 60ºC CE rated IT equipment manufacturers are increasing operating temperatures Allows Data Centres to reduce cooling costs by increasing operating temperatures Hot-air containment solutions provide higher in-rack PDU temperatures Optional environmental monitoring probe with 2 dry contacts (all except Basic ePDUs)

15 15 Simplify Load Balancing  Easily link breakers to outlet groups Easily link breakers to outlet groups Yellow, blue, red, orange, purple and green coding Colour-coded outlet sections match a corresponding circuit breaker Simplifies load balancing Easily identify which circuit breaker feeds which outlets Laser engraved chassis clearly indicates outlet groups and outlet numbers Groups are either branch circuits or phases and are marked on both sides

16 16 G3 Key technology features Basic In-Line Metered Metered Input Metered Outlet SwitchedManaged IEC outlet eGrip plug retention √ N/A √√√√ ±1% IEC Class 1 Billing Grade Accuracy N/A √√√√√ Colour-coded outlet and breaker sections √√√√√√ Hot-Swap eNMC + Optional Temp/Humidity sensor N/A √√√√√ Low-profile form factor √√√√√√ High operating Temperatures √√√√√√ Daisy Chain Network N/A √√√√√ Multiple Install Options √√√√√√ Energy Wise Ready N/A √√√√√ G3 Key Features – Across The Whole Range

17 17 Supervision and Control in a single interface Intelligent Power Manager is a critical part of Eaton’s Intelligent Power Pod for the data centre: Integrates with VMware, Citrix Trigger automatic migration of virtual servers in the event of a power failure Site recovery and full integration in the VMware interface ePDU and UPS supervision and control ePDU and UPS Energy Management En masse Configuration of ePDU En masse Update of ePDU One interface to monitor + control your power usage

18 18 Need Something Special? Dedicated Engineering teams to create your perfect ePDU Dedicated Engineering Teams in centres of excellence to work on specific configurations and significant projects Simple Configuration ChangesComplex Engineering Project Criteria -€10k order or Significant customer for other equipment -Simple change to standard units Criteria -Major project or customer -Specific functionality required

19 19 Need Something Special? Dedicated Engineering teams to create your perfect ePDU Simple Configuration ChangesComplex Engineering Project Quotation - 24 hour turnaround Delivery – 4 weeks from order Quotation – dependant on complexity Delivery – dependant on complexity / approvals / parts needed Outlet changes - Number and type C13, C19, UK, GE, FR Mix up to 3 types of outlets on 1 ePDU Length of 0U chassis Length of input cord, and input plug type

20 20