1 Powerware 9170+ 3 - 18 kVA The modular, scalable, redundant UPS for midrange applications.

Similar presentations


Presentation on theme: "1 Powerware 9170+ 3 - 18 kVA The modular, scalable, redundant UPS for midrange applications."— Presentation transcript:

1 1 Powerware 9170+ 3 - 18 kVA The modular, scalable, redundant UPS for midrange applications

2 2 The Powerware 9170+ It’s about availability Reliability Efficiency Performance

3 3 Powerware 9170+ Applications The 9170+ is designed for the 24/365 availability needs of 3-18 kVA e-business applications featuring: –Servers –Networking devices (hubs, routers and switches) –Telecommunications/PBX –Long Runtime Applications (with new Charger Module) –Process control –Branch offices

4 4 Powerware 9170+ Enhancements –XCP Protocol Compatibility –Increase Watt Rating - Split Phase Modules –Advance Battery Management (ABM) –Improved Front Panel Operations –Firmware Field Upgrade Capability –Active MOV Monitoring

5 5 Powerware 9170+ Powerware 9170+ Overview Modular, global design Scalable N + X redundancy Traditional 9 Series Power Protection Advanced Battery Management (ABM) Optional Charger for Long Runtime Applications Compact footprint/lightweight power and battery modules Enhanced, easy to use interface panel Flexible communication capability

6 6 Four freestanding UPS enclosures 3-slot: 3 kVA 6-slot: 3-9 kVA 9-slot: 3-18 kVA 12 slot: 3-18 kVA Powerware 9170+ System Configurations The Powerware 9170+’s modular design lets users configure any level of power redundancy or battery run-time with optional charger they need.

7 7 Three freestanding Battery Enclosures 6 Slot 9 Slot 12 slot 12 Slot w/charger Two rackmount kit options 3-slot: 3 kVA 6-slot: 3-9 kVA Powerware 9170+ System Configurations

8 8 Model PowerInput/OutputInput/OutputDimensions NumberRatingVoltage 1 Connection(s) ( H x W x D) 2 Weight. PW9170+ 3 slot 3kVA 208-240VACConfigurable 17.8 x 17 x 25.4 in. 66 lb. PW9170+ 6 slot3 to 9kVA208-240VAC Configurable31.5 x 17 x 25.4 in. 103 lb PW9170+ 9 slot 3 to 18kVA208-240VAC Configurable 47 x 24 x 28.4 in. 158 lb PW9170+ 12 slot 3 to 18kVA208-240VAC Configurable60.7 x 24 x 28.4 in 196 lb 6 slot battery cab 31.5 x 17 x 25.4 in 93 lb 9 slot battery cab47 x 24 x 28.4 in148 lb 12 slot battery cab60.7 x 24 x 28.4 in186 lb Battery Module4.2 x 7 x 14.8 in30 lb Split Phase Power Module 100 - 120 & 200 - 240VAC4.2 x 14.1 x 15.3 in17 lb Universal Power Module 200 - 240VAC 4.2 x 14.1 x 15.3 in17 lb Optional Charger Module4.2 x 14.1 x 15.3 in17 lb 1. Nominal input voltage range is 208 - 240VAC with maximum input voltage range of 176 to 276VAC. Split Phase Power Module offers both high and low output voltages, while the Universal Power Module offers only high output voltages.

9 9 Powerware 9170+ Powerware 9170+ Benefits / Features Cost of Ownership Capacity Modular in 3kVA blocks N+X option Charger option

10 10 Powerware 9170+ Powerware 9170+ Standard Features Global Product WW Frequency (47- 63Hz) Selectable WW voltages High efficiency mode Enhanced, Fault Bypass mode Standard hot-swappable internal batteries Continuous on-line, no- break transfer Sinewave Output

11 11 Powerware 9170+ Powerware 9170+ Standard Features Generator compatible Advanced Battery Management (ABM) Wide input voltage 176 - 276 volts <10% input I THD Supports: non-linear loads 3:1 crest factor.9 lead to.5 lagging Power factor corrected

12 12 Powerware 9170+ Powerware 9170+ Standard Features LCD display Complete connectivity offering Com slot(s) RS232 Contact closure Remote EPO capable etc…. Enhanced,Easy diagnostics Power management software - XCP Compatible

13 13 Powerware 9170+ Maximum Availability True double conversion online design –Adheres to IEC guidelines for Class 1 double conversion online UPS –Total independence and complete isolation between input and output for voltage and frequency –Wide input voltage range (176 to 276 VAC) –Frequency correction –Harmonics isolation Double conversion online is universally recognized as the highest performance topology

14 14 Powerware 9170+ Maximum Availability / Reliability Features –Patented Universal Slots Any module - any slot –Hot Swappable Modules All modules with no load interruption –Patented Bypass 6kVA rated

15 15 N+X “Power and LOGIC” Redundancy Patented technology enables true N+X power redundancy The Powerware 9170+ features logic redundancy as well, eliminating any vulnerability to system availability. The logic is contained in each 3kVA Power Module (not in separate redundant logic cards like Symmetra, Nfinity, etc.), allowing true N+X Power and Logic Redundancy No system-level single-point-of-failure in Powerware 9170+ systems Virtually eliminates downtime and enhances serviceability – no need to transfer load to bypass during service Powerware 9170+ Maximum Reliability

16 16 Powerware 9170+ Powerware 9170+ Standard Internal Options Receptacle panels –All cabinets Input cord options –3 & 6 kVA only Locking casters option –3 & 6 Slot only

17 17 Powerware 9170+ Powerware 9170+ Optional Charger Module Optional 20AMP Charger –20 amps of charging capability which can be paralleled for long runtime opportunities –Same Form Factor as 3kVA Power Modules Fits any standard slot –Housed in standard UPS cabinet or special 12 slot battery cabinet (ASY-0653) – Top 3 slots –Example: 18kVA system for 1 hour of runtime –One charger will yield 5.4 hours of recharge time –Two chargers will yield 3.1 hours of recharge time.

18 18 Powerware 9170+ Powerware 9170+ Internal Options Galvanic isolation (factory installation required) –3 Slot Housed in bottom of cabinet Removes bottom slot –6 Slot Mounted vertical rear Reduces receptacles to maximum 4 bays –9 Slot - not available –12 Slot Mounted vertical rear Reduces receptacles to maximum 8 bays

19 19 Powerware 9170+ Powerware 9170+ External Option Rackmount kits Extended runtime –6, 9, & 12 slot cabinets Wall mounted MBC –Make Before Break (MBB) –Break Before Make (BBM) Floor anchoring kits

20 20 Powerware 9170+ Maximum Performance Enhanced, easy-to-use front control panel –Large 4 X 20 character back-lit LCD panel –Programmable for Power Saver Mode, alarm notification and communications –Illuminated indicators for UPS status –Multilingual LCD (English, French, German and Spanish)

21 21 Powerware 9170+ Maximum Performance Flexible communication capabilities SNMP communication RS-232 DB-9 Web browser or modem access Software included On Line, On Generator, On Bypass, EPO notification Two communications slots

22 22 Battery Runtime Chart 1 String 2 String3 String4 String5 String6 String 3kVA 8/2424/5943/9558/14080/17595/125 6kVA 8/2416/4024/5932/8340/103 9kVA 8/2413/3518/4624/59 12kVA 8/2413/3316/40 15kVA 8/2411.5/31 18kVA 8/24 7 String 8 String9 String10 String11 String12 String 3kVA 119/240135/290155/335165/365200/395215/450 6kVA 49/11458/14069/15683/17590/190103/205 9kva 29/6335/8640/10346/11554/12558/140 12kva 19.5/43.524/5929/7033/8036/9041/100 15kva 14.5/31.518/4620.5/5124/5828/6631/73 18kVA 11/31.513/3615.5/4118/4520.5/5124/58 (Full load/Half load) Runtimes above solid line require new optional charger or additional power modules.

23 23 13 string 14 String15 String16 String17 String18 String 3kVA 225/500245/540270/600290/620315/650335/690 6kVA 113/335123/255135/273143/290148/315156/333 9kVA 63/15073/16580/17886/19093/200100/210 12kVA 47/11052/12156/13058/14065/14770/156 15kVA 34/8338/9441.5/10344.5/11346.5/11751/127 18kVA 27/6531.5/7234.5/7736/8338/9441/100 19 String 20 String21 String22 String23 String24 String 3kVA 350/720365/780375/850395/890425/920450/950 6kVA 165/350175/365183/385190/395198/420205/440 9kva 107/225115/240121/255125/270135/280143/290 12kva 75/16580/17585/18590/19595/205100/215 15kva 56/13058/14061/14966/15871/16573/170 18kVA 44/10545/11548/12254/13157/13758/140 Runtimes above solid line require optional charger or additional power modules. Battery Runtime Chart (Full load/Half load)

24 24 Power ware 9170+ Power ware 9170+ Pre-configured System Numbers Pre-configured 9170+ UPS System Numbers: –Displayed on Powerware web site on 9170+ page –Complete 9170+ UPS Systems, including enclosure, Power and Battery Modules. –Available to ship immediately –Customer can order a complete 9170+ UPS System with one part number or configure their own unique 9170+ UPS system – the best of both worlds.

25 25 Powerware 9170+ Powerware 9170+ Pre-configured System Numbers