2
Impressed Current Zebra Cassette CorroDiscSurface Embedded Sacrificial Anode ZLA Roll Anode GSC Super Anode Clip On Anode Monitoring and Control Camur Conductive coating Surface mounted ribbon anode Mesh in precast stick-on shapes Ti wire in acid resistant cylinder for embedment Zinc sheet with self adhesive activator Rolled ZLA grouted in drill hole ZLA block for embedment in repair ZLA block in precast container Remote monitoring and control
3
An area of reinforcement becomes anodic due to chloride or carbonation ingress. Corrosion is stopped if: Oxygen at cathode stopped Full immersion Small cathode Resistance of electrolyte high Low due to chloride & water Electrons supplied from alternative anode Anodic and cathodic reaction are critical to how the cell works.
4
Galvanic Anode Current C u r r e n t F l o w
5
High life cycle cost Particularly for small projects
6
Zebra Anode Zebra PDR Tape Zebra PDR Concrete Wearing Surface Bond Coats Layers of a Zebra System for the wearing surface of a car park deck
7
Building facadeCar park capillary rise zone Balcony soffitsCar park slab
10
Pipe tunnel, poor accessPrestressed bridge T-Roffs Car park capillary rise area Cast insitu bridge beamRoof of Tunnel Soffit Brdige deck soffit
11
CorroDisc 125 – 125mm diameter circular surface applied anode typically applied on a rectangular grid to give 4-8 anodes/m 2 CorroDisc R – 60x400mm wide surface applied anode typically applied in line to give 3-4 anodes/m 2 MMO coated titanium mesh
12
Pressing CorroDisc R onto surface Pressing CorroDisc 125 onto surface
13
Bus interface Computer 1 zone system (Available for control and monitoring of trial areas). Transformer Rectifier
14
3 zone system with all anode beds in same location. Concrete Structure 220/240 V Power Supply
15
2 Zones3 Zones Right: 3 zone system where anode beds separated. Note wireless link of bus cable. Working systems. Concrete Structure
17
A small potential shift gives cathodic prevention, i.e. a high chloride corrosion threshold for cathodic steel. Use low output anodes for incipient anode protections. A large potential shift gives cathodic protection, i.e. immunity from corrosion for active steel. Use high out put anodes (ZLA range) for true CP and no breakout. SACP systems must provide 100mv 24hr potential decay criteria
18
ZAP output LiOH output Intersection of steel and anode tests gives polarisation expected from anode Test system set up
19
Roll Anode and GSC Super Anode derived for ZLA and both give CP meeting 100mv criteria. Roll of ZLA as applied to the surface of concrete to provide full CP meeting 100 mv criteria
20
BalconiesWalkwaysFacadesBridges After ZLA Application After Coating
21
Anode string connected to rebar 27 mm diameter Roll Anode Typical Roll Anode Installation
22
Anode string connected to rebar 30/20 GSC Super Anode
25
1 2 3 1.5m 1.7m