Download presentation
Presentation is loading. Please wait.
Published byJack Paul Modified over 8 years ago
1
Date of download: 5/28/2016 Copyright © 2016 SPIE. All rights reserved. Diagrammatic representation of the eyeball model showing location of the main optical planes and the changes in corneal geometry and position with loading [change in intraocular pressure (p)]. Figure Legend: From: Effect of material properties of the eyeball coat on optical image stability J. Biomed. Opt. 2008;13(5):054013-054013-6. doi:10.1117/1.2975844
2
Date of download: 5/28/2016 Copyright © 2016 SPIE. All rights reserved. Shift in optical focus B plotted against intraocular pressure p for an eye model with a cornea of material M1 (described in Table ) for varying values of Qsclera. Figure Legend: From: Effect of material properties of the eyeball coat on optical image stability J. Biomed. Opt. 2008;13(5):054013-054013-6. doi:10.1117/1.2975844
3
Date of download: 5/28/2016 Copyright © 2016 SPIE. All rights reserved. Shift in optical focus B plotted against intraocular pressure p for an eye model with a cornea of material M2 (described in Table ) for varying values of Qsclera. Figure Legend: From: Effect of material properties of the eyeball coat on optical image stability J. Biomed. Opt. 2008;13(5):054013-054013-6. doi:10.1117/1.2975844
4
Date of download: 5/28/2016 Copyright © 2016 SPIE. All rights reserved. Shift in optical focus B plotted against intraocular pressure p for an eye model with a cornea of material M3 (described in Table ) for varying values of Qsclera. Figure Legend: From: Effect of material properties of the eyeball coat on optical image stability J. Biomed. Opt. 2008;13(5):054013-054013-6. doi:10.1117/1.2975844
5
Date of download: 5/28/2016 Copyright © 2016 SPIE. All rights reserved. Shift in optical focus B plotted against intraocular pressure p for an eye model with a cornea of material M2 (described in Table ), Qsclera=5 for varying values of limbal rigidity α (multipliers in parentheses indicate the ratio Qlimbus). Figure Legend: From: Effect of material properties of the eyeball coat on optical image stability J. Biomed. Opt. 2008;13(5):054013-054013-6. doi:10.1117/1.2975844
6
Date of download: 5/28/2016 Copyright © 2016 SPIE. All rights reserved. Shift in optical focus B plotted against intraocular pressure p for an eye model with a cornea of material M2 (described in Table ), Qsclera=4 for varying values of limbal rigidity α (multipliers in parentheses indicate the ratio Qlimbus). Figure Legend: From: Effect of material properties of the eyeball coat on optical image stability J. Biomed. Opt. 2008;13(5):054013-054013-6. doi:10.1117/1.2975844
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.