1 Gas Billing 2009. 12. KRISS Kyung-Am Park
2
2 KRISS Fluid Flow Group High pressure gas flow Lower than 10,000 m3/h, 0.18% -- 0.16% 10,000 m3/h ~ ??, limit criteria U < 0.2% Build-up with sonic nozzles Oil flow Spindle oil system is ready for (bilateral) KC Light oil system maybe ready for KC next year Wind velocity measurement
3
3 Gas selling unit Korea Gas Company 32 domestic gas dealers Consumers Gas flow measurement at measuring condition P, T (m3/h) Volume conversion from measuring condition to reference condition Volume corrector, Volume correction factor Conversion to Energy ----- billing maybe from 2011 Constant CV – Volume selling ~ Energy selling 0 C, 1.013 bar Measuring condition/conversion
4
4 NG volume correction factor for domestic user Volume correction equation factor K -Compressibility factor ~ 1
5
5 Gas flow pattern Real time pattern - 2002 ~ 2007 year (average of 5 year) (Total gas supply per hour) – (Total gas supply a day)*(Industry supply ratio)/24 - assume “Gas flow of industrial use is constant” “Q” is obtained
6
6 Gas pressure Measured average gas pressure: 22.46 mbar Atmospheric pressure: use average value of 10 years obtained metrological observatory (every 3 hours) – 22 places Attitude correction City hall attitude is used Weighted average of apartment and house – 10.5 m
7
7 Gas temperature Gas temperature in outside gas meter - Atmospheric temperature: use average value of 10 years obtained metrological observatory (every 1 hours) – 22 places Gas temperature in indoor gas meter in apartment - Length of gas pipe line in indoor - Gas flow rate - Indoor air temperature : 8000 temperature sensors for 3 years (Gas T.) = (Indoor air T.) – (ratio of T obtained be Exp.)*{(Indoor air T.)– (Ambient T.)} Weighted average gas T. is obtained.
8
8 Volume correction factor in Seoul Correction factor 0.9983 is used in Seoul area for 1 year from Jan. to Dec. 2009
9
9 Calorific value factor Volume was unit of gas sale Try to change from Volume to Energy Natural gas supplied from 3 imported spots CV of natural gas may be different even in the supply area of one domestic gas dealer Now, need CV factor : BTU factor - How to divide NG supply area - what is acceptable CV difference ??
10
10 Using different natural gas?? Consider billing Gas burners - efficiency, CO, NOx … Gas turbine NGV Flame temperature …… Energy flow – Calorific value * gas flow rage
11
11 Comparison of interchangeability suggestion - 1
12
12 Comparison of interchangeability suggestion - 2
13
13 Gas Quality Wobbe: 14.6 ~ 15.7 kWh/m3 CV: 11.0 ~ 12.5 kWh/m3 Methane: above 85% H2S: below 6 mg/m3 Total sulfur: below 50 mg/m3 HC dew point: below -5 C Water dew point : below -12 C at 7MPa CO2: below 2.5 mole %