Medical Applications 6 contributions on Particle therapy: Magnets for
Accelerators Gantries 2 contributions on magnet design: fast ramping SC magnets Special Magnet for experiment 100 Tm (1.5 T) 300 Tm (4.5 T) 1 T/s Medical Applications Summary BeMa workshop dec Marco Schippers,PSI
2
Joseph Minervini, MIT MEVION S250 Very small / light cyclotron
For therapy Coil construction SC Cyclotron for PET Isotope Production Easy to operate Small footprint Medical Applications Summary BeMa workshop dec Marco Schippers,PSI
3
Joseph Minervini, MIT CONCLUSION: Ironless Synchrocyclotron
Shielding coils Main coil CONCLUSION: SC magnets in a cyclotron make sense: lighter and smaller Ironless or nearly ironless cyclotrons are feasible Medical Applications Summary BeMa workshop dec Marco Schippers,PSI
4
Gantries: Yoshiyuki Iwata, NIRS Marco Schippers, PSI
Alex Gerbershagen, PSI Medical Applications Summary BeMa workshop dec Marco Schippers,PSI
5
scanning Down-stream scanning: + small aperture,
- large radius because of SAD - small spots difficult X Y Rgantry X Y Rgantry Up-stream scanning: + parallel + small gantry radius + small spots possible - wide aperture SC magnet SAD = 1.5 m Medical Applications Summary BeMa workshop dec Marco Schippers,PSI
6
Yoshiyuki Iwata, NIRS Curved 18-26 degr ~3 T 0.3 T/s LHe free
Combined function SC magnets (BM01~BM06) →No quadrupole magnet required Scanning magnets on top →Large scan size →Square irradiation field →Parallel beam Curved degr ~3 T 0.3 T/s LHe free Medical Applications Summary BeMa workshop dec Marco Schippers,PSI
7
Keep fast E change: dB/dt > 10%/s (≈ 0.8 T/s)
Alex Gerbershagen, PSI Marco Schippers, PSI Gantry2 SC magnets Keep fast E change: dB/dt > 10%/s (≈ 0.8 T/s) Medical Applications Summary BeMa workshop dec Marco Schippers,PSI
8
Beam Optics Gantry-2: NC & SC
Alex Gerbershagen, PSI Marco Schippers, PSI Beam Optics Gantry-2: NC & SC Gantry 2 optics: Momentum acceptance: Δp/p = 0.7 % Q M L 1 2 A 3 4 5 6 7 W T U K B P G D H C S I O E N D=0 Dispersion (1%dp) SC Bending sections: dipole +combined Q+D : dispersion suppression => Very large momentum acceptance: Δp/p > 10 % D=0 S M D 5 Q 1 3 4 A L B C 2 E F 6 7 K U P G H 2 x 45° bending magnets +3 quadrupoles 3 x 20° bending magnets 3 x 20° bending magnets W S M Medical Applications Summary BeMa workshop dec Marco Schippers,PSI
9
Alex Gerbershagen, PSI Large energy acceptance: 20% Energy modulation (≈30% of Range) without dB/dt Achromatic POSITION of pencil beam CONSTANT for all E BUT : pencil beam size will vary with E => imaging correction necessary with two nc quads Medical Applications Summary BeMa workshop dec Marco Schippers,PSI 9
10
Shlomo Caspi and Lucas Brouwer, LBNL
Canted Coil Solenoid Canted Cosine Theta Mandrels easy winding Curved multipoles Medical Applications Summary BeMa workshop dec Marco Schippers,PSI
11
Shlomo Caspi Lucas Brouwer, LBNL Multi layer options
The CCT advantages:reduce stress, improve training and “short-sample” expectation, field quality etc The CCT design is well suited for curved SC gantry magnets Medical Applications Summary BeMa workshop dec Marco Schippers,PSI
12
SIS300 dipoles: fast cycled and curved magnet
Fabricatore, INFN 100 Tm (1.5 T) 300 Tm (4.5 T) 1 T/s SIS300 dipoles: fast cycled and curved magnet Field quality is depressed at low field. This effect is independent on ramp rate 1- Persistent currents in SC filaments 2- Inter-filaments/strands coupling currents ac losses and perturbation of field quality. IMPORTANT PARAMETERS: Filament diameter Nr strands Interfilament matrix Medical Applications Summary BeMa workshop dec Marco Schippers,PSI
13
Fabricatore, INFN Conclusions:
dB/dt : limitations are mainly determined by ac losses. few T/s => eddy currents in metallic structures and yokes, However: field quality OK Intrastrand coupling currents: major source of field quality perturbation A low loss wire will be one of the main issues for future developments Medical Applications Summary BeMa workshop dec Marco Schippers,PSI
14
Renuka Rajput Ghoshal , Jefferson Lab
Medical Applications Summary BeMa workshop dec Marco Schippers,PSI
15
Design Iterations: Renuka Rajput Ghoshal , Jefferson Lab
Cryogenic Cooling Design Original Design Optimized Design Pressure Atm Sub-atm LHe temp 4.2K 3.6K Temp Margin 1.12K 1.71K SC Correction coils Original Design Optimized Design Location OD of main magnet coils (far from target area) Inside the bore – (close to target area) Size Large (Ø ~1.5m) Small (Ø ~50mm) Comment Needs very strong coils to compensate for field uniformity Needs less field & easier to assemble Final design will be based on field map of the rest of the magnet Medical Applications Summary BeMa workshop dec Marco Schippers,PSI
16
Discussion Damage, distinguish: Low dose (rate) damage of insulation
Medium doses heating of SC or NC matrix: quench risk Types of SC: Experiences, Nb3Sn, HTC: almost “normally used” Power vs energy consumption in dB/dt (cryocoolers use ~8kW) Medical Applications Summary BeMa workshop dec Marco Schippers,PSI