Presentation is loading. Please wait.

Presentation is loading. Please wait.

Progress Report of NPLI Fluid Flow Measurement Standards Activity (2010-11) Shiv Kumar Jaiswal Senior Scientist Fluid Flow Measurement Standards (Apex.

Similar presentations


Presentation on theme: "Progress Report of NPLI Fluid Flow Measurement Standards Activity (2010-11) Shiv Kumar Jaiswal Senior Scientist Fluid Flow Measurement Standards (Apex."— Presentation transcript:

1 Progress Report of NPLI Fluid Flow Measurement Standards Activity (2010-11) Shiv Kumar Jaiswal Senior Scientist Fluid Flow Measurement Standards (Apex Level Standards and Industrial Metrology Division) National Physical Laboratory Dr. K.S. Krishnan Road New Delhi -110012 INDIA

2 (1)Renovation of Fluid Flow Measurement Laboratory (estimated cost US$ 100K) The renovation work of the laboratory is continuing since October 2010 and it is on the verge of completion.

3

4

5 We are developing a prototype water flow calibration system (Primary Standard of water Flow) of size DN100. The installation and integration of various parts of this system i.e. weighing tanks, load cells, flow control valves, drain valves, flowmeters, On/Off valves, diverter, fishtail, pneumatic pipes, pressure regulator devices, etc. have been completed. Presently Automation of the System is in Progress. (2) Development of the Prototype Water Flow Calibration System (as per ISO 4185)

6 DN 200 DN 100 DN 50 New

7 Drain ValvePlate for keeping Dead Weights

8 Flow Control Valve Reference Flowmeter Sensor Gate Valve

9 Flowmeter Signal ConditionersLoad Cell Indicator

10 Platform for Accessing Tanks & Diverter Mechanism

11 3. Water Meter Testing Facility Presently the Group provides the Water Meter Testing Services up to 50 mm (i.e. 2”) diameter size as per IS 779, IS 6784 and ISO 4064 to the Water Meter Manufacturing Companies, State Govt. Water Boards, etc. These meters are of Woltman type.

12 Water Meter Testing Facility Standard Volumetric Vessel Timer for Continuous & Discontinuous Test Standard Rotameters Pumps Line for Accuracy Test Line for Life Test Gate Valves Water Meters

13 4. Planned for Gas Flow Calibration Facility We have received the grant of US$ 500K for establishment of Gas Flow Calibration Facility (both Primary and Working/ Transfer Standards). Very soon, we are going for Global Tender for the Transfer Standards. The flow range is 0.001 lpm to 1000 lpm and expanded uncertainty (at k=2) is 0.20%.

14 Thank You Very Much for Your Attention