P RACTICE C ODE L OOK U P Two Minute Drill #7 Copyright 2005 Ted "Smitty" Smith
2
D IRECTIONS Left click on the presentation ICON located at the bottom of the slide directory to the left of the this slide. Each slide will transition to the correct answer automatically in 2:00 minutes. The correct answer will transition in 5 seconds. Do not worry about writing down the correct answer for now. You will have the opportunity to do that at the end of the two minute drill Good luck Copyright 2005 Ted "Smitty" Smith
3
F URTHER M ORE You have seen all of these questions before. This time the slides will transition at different rates of speed. Remember do not worry about writing down the right answer for now. When you reach the end all of the slides will be repeated without the timer so you can take your time to find the ones you missed and write down the correct answers then. We have also added several multiple choice questions to prepare you for the actual exam. The next three two- minute drills you will be doing will have only multiple choice questions and will be weighted similarly to the actual tests you will be taking. Click on the slide to proceed. Copyright 2005 Ted "Smitty" Smith
4
G ROUNDING Electrical systems that are grounded shall be connected to earth in a manner that will __________. A. Limit voltages due to lightning, line surges or unintentional contact with higher voltages B. Stabilize the voltage-to-ground during normal operation C. Facilitate overcurrent protection device operation in case of ground faults D. Both a and b Copyright 2005 Ted "Smitty" Smith
5
G ROUNDING D. Both a and b 250.2(A)(1) Copyright 2005 Ted "Smitty" Smith
6
E QUIPMENT Electrically heated smoothing irons shall be equipped with an identified _________ means. A. disconnecting B. temperature limiting C. current limiting D. none of these Copyright 2005 Ted "Smitty" Smith
7
E QUIPMENT B. Temperature limiting 422.46 Copyright 2005 Ted "Smitty" Smith
8
G ROUNDING All grounding electrodes as described in 250. 52(A)(1) through 250.52(A)(6) that are ____________ at each building or structure served shall be bonded together to form the grounding electrode system. Copyright 2005 Ted "Smitty" Smith
9
G ROUNDING Present 250.50 Copyright 2005 Ted "Smitty" Smith
10
E QUIPMENT Embedded deicing and snowmelt equipment cables, units and panels shall not be installed where they bridge ____________, unless provisions are made for expansion and contraction. A. roads B. over water spans C. runways D. expansion joints Copyright 2005 Ted "Smitty" Smith
11
E QUIPMENT D. Expansion joints 426.20(E) Copyright 2005 Ted "Smitty" Smith
12
S ERVICES A cable tray may serve to carry service-entrance conductors along with other conductors as long as there is a ________. Copyright 2005 Ted "Smitty" Smith
13
S ERVICES Barrier 230.44Ex Copyright 2005 Ted "Smitty" Smith
14
E QUIPMENT U SE Wiring installed in aircraft hangars in unclassified locations that are adjacent to areas in which flammable liquids or vapors are not likely to be released, such as stock rooms or electrical control rooms, which are adequately ventilated and are effectively cut off from the hangar itself by walls or partitions, shall be permitted to be of any suitable type wiring method recognized by chapter 3 of the NEC. True or False Copyright 2005 Ted "Smitty" Smith
15
E QUIPMENT U SE True Exception to 513.7 Copyright 2005 Ted "Smitty" Smith
16
S ERVICES True of False, the disconnect for a TVSS is not counted as one of the six disconnects allowed for a service. Copyright 2005 Ted "Smitty" Smith
17
S ERVICES True 230.71(A) Copyright 2005 Ted "Smitty" Smith
18
S ERVICES The service head for entrance-conductors should be located above the point of attachment but may be located elsewhere as long as the attachment is within __________ feet. Copyright 2005 Ted "Smitty" Smith
19
S ERVICES 2 feet 230.54(C) Ex Copyright 2005 Ted "Smitty" Smith
20
E QUIPMENT U SE The 480 volt auxiliary equipment of an electric discharge lamp is permanently installed in a luminaire and the luminaire is mounted on a pole for the illumination of a highway. What is the minimum height above the ground the auxiliary equipment must be mounted? Copyright 2005 Ted "Smitty" Smith
21
E QUIPMENT U SE 22 ft 210.6(D)(1)(a) Copyright 2005 Ted "Smitty" Smith
22
R ACEWAYS ENT must be secured in place every ______. A. 12 inches B. 18 inches C. 24 inches D. 36 inches Copyright 2005 Ted "Smitty" Smith
23
R ACEWAYS D. 36 inches 362.30(A) Copyright 2005 Ted "Smitty" Smith
24
R ACEWAYS The minimum burial depth for a nonmetallic raceway with no vehicular traffic shall be __________________ inches. Copyright 2005 Ted "Smitty" Smith
25
R ACEWAYS 4" Table 300.5 Col. 3 Copyright 2005 Ted "Smitty" Smith
26
C ALCULATIONS A conductor passing through a junction box with a loop length of ______________ shall be counted twice for box fill calculations. Copyright 2005 Ted "Smitty" Smith
27
C ALCULATIONS Twice the minimum length required by Article 300.14 314.16(B)(1) Copyright 2005 Ted "Smitty" Smith
28
O VERCURRENT PROTECTION Equipment intended to break current at other than fault levels shall have an interrupting rating of the system voltage sufficient for the current that must be interrupted. True or False Copyright 2005 Ted "Smitty" Smith
29
O VERCURRENT P ROTECTION True 110.9 Copyright 2005 Ted "Smitty" Smith
30
E QUIPMENT Exposed conductive parts of luminares shall be ___________ A. grounded B. painted C. Bonded D. a and b Copyright 2005 Ted "Smitty" Smith
31
E QUIPMENT A. Grounded 410.18 (A) Copyright 2005 Ted "Smitty" Smith
32
E QUIPMENT U SE A ballast in a fluorescent luminaire that is used for egress lighting and energized only during a failure of the normal supply shall not have ________________. Copyright 2005 Ted "Smitty" Smith
33
E QUIPMENT U SE Thermal Protection 410.73(E)(4) Copyright 2005 Ted "Smitty" Smith
34
G ROUNDING The earth shall not be considered as an effective ground fault current path. True or False Copyright 2005 Ted "Smitty" Smith
35
G ROUNDING True 250.4(A)(5) Copyright 2005 Ted "Smitty" Smith
36
O VERCURRENT P ROTECTION Can the next standard sized overcurrent protective device be used to protect tap conductors for transformer secondary conductors? Copyright 2005 Ted "Smitty" Smith
37
O VERCURRENT P ROTECTION NO 240.21(C) Copyright 2005 Ted "Smitty" Smith
38
F EEDERS AND B RANCH C IRCUITS Where the premises wiring system has branch circuits supplied from more than one nominal voltage system, each ungrounded conductor of a branch circuit, where accessible, shall be identified by __________. Copyright 2005 Ted "Smitty" Smith
39
F EEDERS AND B RANCH C IRCUITS System 210.5(C) Copyright 2005 Ted "Smitty" Smith
40
E QUIPMENT U SE The size of the industrial control panel supply conductor shall have an ampacity not less than ________ percent of the full load current of all resistance heating loads plus 125% of the full load current rating of the highest rated motor plus the sum of the full load current ratings of all connected motors and apparatus based on their duty cycle that may be in operation at the same time. Copyright 2005 Ted "Smitty" Smith
41
E QUIPMENT U SE 125% 409.20 Copyright 2005 Ted "Smitty" Smith
42
E QUIPMENT U SE Handhold enclosure covers shall have an _____________________ that prominently identifies the function of the enclosure. Copyright 2005 Ted "Smitty" Smith
43
E QUIPMENT U SE identifying mark or logo 314.30(D) Copyright 2005 Ted "Smitty" Smith
44
C ONDUCTORS AND C ABLE A SSEMBLIES Type MC cable does not have to be supported if it is not more than 2 feet long and it is being used to provide flexibility to a termination. True or False Copyright 2005 Ted "Smitty" Smith
45
C ONDUCTORS AND C ABLE A SSEMBLIES True 320.30(D) Copyright 2005 Ted "Smitty" Smith
46
E QUIPMENT U SE A 1/2" knockout will be made in a fluorescent light fixture that will be mounted over a junction box. The light fixture will be mounted with toggle bolts. A 1/2" chase nipple will be installed so that the conductors from the box can be brought into the fixture for make up. Is this is legal installation according to the NEC? Copyright 2005 Ted "Smitty" Smith
47
E QUIPMENT U SE No 410.14(A) Copyright 2005 Ted "Smitty" Smith
48
E QUIPMENT U SE Is thermal protection required for the ballast of a fluorescent exit light? Copyright 2005 Ted "Smitty" Smith
49
E QUIPMENT U SE No 410.73(E)(3) Copyright 2005 Ted "Smitty" Smith
50
E QUIPMENT U SE Is the terminal of an electric discharge lamp rated in excess of 1000V considered to be a live part according to the NEC? Copyright 2005 Ted "Smitty" Smith
51
E QUIPMENT U SE Yes 410.80 (C) Copyright 2005 Ted "Smitty" Smith
52
G ROUNDING Is an equipment grounding conductor required to be installed in listed metal flexible conduit that is 2 feet in length and is used only to provide flexible connection to a motor? Copyright 2005 Ted "Smitty" Smith
53
G ROUNDING Yes 250.118(5)(d) Copyright 2005 Ted "Smitty" Smith
54
G ROUNDING Exposed, non-current carrying, metal parts of motion picture projection equipment that is fastened in place shall be grounded regardless of voltage. True or False Copyright 2005 Ted "Smitty" Smith
55
G ROUNDING True 250.112 (H Copyright 2005 Ted "Smitty" Smith
56
G ROUNDING Exposed, non-current carrying, metal parts of equipment that is connected by cord and plug, regardless of voltage, that is installed in non- hazardous locations shall be grounded. True or False Copyright 2005 Ted "Smitty" Smith
57
G ROUNDING False 250.114 (1) and (2) Copyright 2005 Ted "Smitty" Smith
58
G ROUNDING The connection of a grounding electrode conductor or bonding jumper to fire-proofed structural steel shall not be required to be accessible if it is made with an irreversible compression connection. True or False Copyright 2005 Ted "Smitty" Smith
59
G ROUNDING True 250.68 (A) Exep. 2 Copyright 2005 Ted "Smitty" Smith
60
G ROUNDING A ground rod of 8 feet in length must be installed so that the connection point of the grounding electrode conductor remains accessible and above the ground. True or False Copyright 2005 Ted "Smitty" Smith
61
G ROUNDING False 250.53 (G) and 250.68 (A) Exp. 1 Copyright 2005 Ted "Smitty" Smith
62
E QUIPMENT U SE Handhold enclosure covers shall have an _____________________ that prominently identifies the function of the enclosure. Copyright 2005 Ted "Smitty" Smith
63
E QUIPMENT U SE identifying mark or logo 314.30(D) Copyright 2005 Ted "Smitty" Smith
64
G ROUNDING The ground fault current path of the equipment grounding system is intended to return fault current back to the earth. True or False Copyright 2005 Ted "Smitty" Smith
65
G ROUNDING False 250.2 Back to the source Copyright 2005 Ted "Smitty" Smith
66
F EEDERS AND B RANCH C IRCUITS Where calculations result in a fraction of an ampere that is less than __________, such fractions shall be permitted to be dropped. Copyright 2005 Ted "Smitty" Smith
67
F EEDERS AND B RANCH C IRCUITS.5 220.5(B) Copyright 2005 Ted "Smitty" Smith
68
F EEDERS AND B RANCH C IRCUITS Outlets for heavy duty lamp holders shall be calculated at a minimum of _______ volt-amperes. Copyright 2005 Ted "Smitty" Smith
69
F EEDERS AND B RANCH C IRCUITS 600 220.14(E) Copyright 2005 Ted "Smitty" Smith
70
F EEDERS AND B RANCH C IRCUITS A load not less than ___________ volt amperes shall be included for each 2-wire laundry branch circuit installed as required by 210.11(C)(2). Copyright 2005 Ted "Smitty" Smith
71
F EEDERS AND B RANCH C IRCUITS 1500 220.52(B) Copyright 2005 Ted "Smitty" Smith
72
F EEDERS AND B RANCH C IRCUITS An alternate load calculation for determine if the existing service or feeder is of sufficient capacity to serve additional loads in an existing dwelling unit is found in __________________. Copyright 2005 Ted "Smitty" Smith
73
F EEDERS AND B RANCH C IRCUITS 220.83 Copyright 2005 Ted "Smitty" Smith
74
F EEDERS AND B RANCH C IRCUITS The rules for calculating the load on fixed multi- outlet assemblies are found in _______________. Copyright 2005 Ted "Smitty" Smith
75
F EEDERS AND B RANCH C IRCUITS 220.14(H) Copyright 2005 Ted "Smitty" Smith
76
T HE E ND Each of the slides will now be repeated. They are not timed in this segment. To change a slide, click on the side with your left mouse button. Be sure to physically look up the answers in your code book to improve your look up speed and skill. Copyright 2005 Ted "Smitty" Smith
77
G ROUNDING Electrical systems that are grounded shall be connected to earth in a manner that will __________. A. Limit voltages due to lightning, line surges or unintentional contact with higher voltages B. Stabilize the voltage-to-ground during normal operation C. Facilitate overcurrent protection device operation in case of ground faults D. Both a and b Copyright 2005 Ted "Smitty" Smith
78
G ROUNDING D. Both a and b 250.2(A)(1) Copyright 2005 Ted "Smitty" Smith
79
E QUIPMENT Electrically heated smoothing irons shall be equipped with an identified _________ means. A. disconnecting B. temperature limiting C. current limiting D. none of these Copyright 2005 Ted "Smitty" Smith
80
E QUIPMENT B. Temperature limiting 422.46 Copyright 2005 Ted "Smitty" Smith
81
G ROUNDING All grounding electrodes as described in 250. 52(A)(1) through 250.52(A)(6) that are ____________ at each building or structure served shall be bonded together to form the grounding electrode system. Copyright 2005 Ted "Smitty" Smith
82
G ROUNDING Present 250.50 Copyright 2005 Ted "Smitty" Smith
83
E QUIPMENT Embedded deicing and snowmelt equipment cables, units and panels shall not be installed where they bridge ____________, unless provisions are made for expansion and contraction. A. roads B. over water spans C. runways D. expansion joints Copyright 2005 Ted "Smitty" Smith
84
E QUIPMENT D. Expansion joints 426.20(E) Copyright 2005 Ted "Smitty" Smith
85
S ERVICES A cable tray may serve to carry service-entrance conductors along with other conductors as long as there is a ________. Copyright 2005 Ted "Smitty" Smith
86
S ERVICES Barrier 230.44Ex Copyright 2005 Ted "Smitty" Smith
87
E QUIPMENT U SE Wiring installed in aircraft hangars in unclassified locations that are adjacent to areas in which flammable liquids or vapors are not likely to be released, such as stock rooms or electrical control rooms, which are adequately ventilated and are effectively cut off from the hangar itself by walls or partitions, shall be permitted to be of any suitable type wiring method recognized by chapter 3 of the NEC. True or False Copyright 2005 Ted "Smitty" Smith
88
E QUIPMENT U SE True Exception to 513.7 Copyright 2005 Ted "Smitty" Smith
89
S ERVICES True of False, the disconnect for a TVSS is not counted as one of the six disconnects allowed for a service. Copyright 2005 Ted "Smitty" Smith
90
S ERVICES True 230.71(A) Copyright 2005 Ted "Smitty" Smith
91
S ERVICES The service head for entrance-conductors should be located above the point of attachment but may be located elsewhere as long as the attachment is within __________ feet. Copyright 2005 Ted "Smitty" Smith
92
S ERVICES 2 feet 230.54(C) Ex Copyright 2005 Ted "Smitty" Smith
93
E QUIPMENT U SE The 480 volt auxiliary equipment of an electric discharge lamp is permanently installed in a luminaire and the luminaire is mounted on a pole for the illumination of a highway. What is the minimum height above the ground the auxiliary equipment must be mounted? Copyright 2005 Ted "Smitty" Smith
94
E QUIPMENT U SE 22 ft 210.6(D)(1)(a) Copyright 2005 Ted "Smitty" Smith
95
R ACEWAYS ENT must be secured in place every ______. A. 12 inches B. 18 inches C. 24 inches D. 36 inches Copyright 2005 Ted "Smitty" Smith
96
R ACEWAYS D. 36 inches 362.30(A) Copyright 2005 Ted "Smitty" Smith
97
R ACEWAYS The minimum burial depth for a nonmetallic raceway with no vehicular traffic shall be __________________ inches. Copyright 2005 Ted "Smitty" Smith
98
R ACEWAYS 4" Table 300.5 Col. 3 Copyright 2005 Ted "Smitty" Smith
99
C ALCULATIONS A conductor passing through a junction box with a loop length of ______________ shall be counted twice for box fill calculations. Copyright 2005 Ted "Smitty" Smith
100
C ALCULATIONS Twice the minimum length required by Article 300.14 314.16(B)(1) Copyright 2005 Ted "Smitty" Smith
101
O VERCURRENT PROTECTION Equipment intended to break current at other than fault levels shall have an interrupting rating of the system voltage sufficient for the current that must be interrupted. True or False Copyright 2005 Ted "Smitty" Smith
102
O VERCURRENT P ROTECTION True 110.9 Copyright 2005 Ted "Smitty" Smith
103
E QUIPMENT Exposed conductive parts of luminares shall be ___________ A. grounded B. painted C. Bonded D. a and b Copyright 2005 Ted "Smitty" Smith
104
E QUIPMENT A. Grounded 410.18 (A) Copyright 2005 Ted "Smitty" Smith
105
E QUIPMENT U SE A ballast in a fluorescent luminaire that is used for egress lighting and energized only during a failure of the normal supply shall not have ________________. Copyright 2005 Ted "Smitty" Smith
106
E QUIPMENT U SE Thermal Protection 410.73(E)(4) Copyright 2005 Ted "Smitty" Smith
107
G ROUNDING The earth shall not be considered as an effective ground fault current path. True or False Copyright 2005 Ted "Smitty" Smith
108
G ROUNDING True 250.4(A)(5) Copyright 2005 Ted "Smitty" Smith
109
O VERCURRENT P ROTECTION Can the next standard sized overcurrent protective device be used to protect tap conductors for transformer secondary conductors? Copyright 2005 Ted "Smitty" Smith
110
O VERCURRENT P ROTECTION NO 240.21(C) Copyright 2005 Ted "Smitty" Smith
111
F EEDERS AND B RANCH C IRCUITS Where the premises wiring system has branch circuits supplied from more than one nominal voltage system, each ungrounded conductor of a branch circuit, where accessible, shall be identified by __________. Copyright 2005 Ted "Smitty" Smith
112
F EEDERS AND B RANCH C IRCUITS System 210.5(C) Copyright 2005 Ted "Smitty" Smith
113
E QUIPMENT U SE The size of the industrial control panel supply conductor shall have an ampacity not less than ________ percent of the full load current of all resistance heating loads plus 125% of the full load current rating of the highest rated motor plus the sum of the full load current ratings of all connected motors and apparatus based on their duty cycle that may be in operation at the same time. Copyright 2005 Ted "Smitty" Smith
114
E QUIPMENT U SE 125% 409.20 Copyright 2005 Ted "Smitty" Smith
115
E QUIPMENT U SE Handhold enclosure covers shall have an _____________________ that prominently identifies the function of the enclosure. Copyright 2005 Ted "Smitty" Smith
116
E QUIPMENT U SE identifying mark or logo 314.30(D) Copyright 2005 Ted "Smitty" Smith
117
C ONDUCTORS AND C ABLE A SSEMBLIES Type MC cable does not have to be supported if it is not more than 2 feet long and it is being used to provide flexibility to a termination. True or False Copyright 2005 Ted "Smitty" Smith
118
C ONDUCTORS AND C ABLE A SSEMBLIES True 320.30(D) Copyright 2005 Ted "Smitty" Smith
119
E QUIPMENT U SE A 1/2" knockout will be made in a fluorescent light fixture that will be mounted over a junction box. The light fixture will be mounted with toggle bolts. A 1/2" chase nipple will be installed so that the conductors from the box can be brought into the fixture for make up. Is this is legal installation according to the NEC? Copyright 2005 Ted "Smitty" Smith
120
E QUIPMENT U SE No 410.14(A) Copyright 2005 Ted "Smitty" Smith
121
E QUIPMENT U SE Is thermal protection required for the ballast of a fluorescent exit light? Copyright 2005 Ted "Smitty" Smith
122
E QUIPMENT U SE No 410.73(E)(3) Copyright 2005 Ted "Smitty" Smith
123
E QUIPMENT U SE Is the terminal of an electric discharge lamp rated in excess of 1000V considered to be a live part according to the NEC? Copyright 2005 Ted "Smitty" Smith
124
E QUIPMENT U SE Yes 410.80 (C) Copyright 2005 Ted "Smitty" Smith
125
G ROUNDING Is an equipment grounding conductor required to be installed in listed metal flexible conduit that is 2 feet in length and is used only to provide flexible connection to a motor? Copyright 2005 Ted "Smitty" Smith
126
G ROUNDING Yes 250.118(5)(d) Copyright 2005 Ted "Smitty" Smith
127
G ROUNDING Exposed, non-current carrying, metal parts of motion picture projection equipment that is fastened in place shall be grounded regardless of voltage. True or False Copyright 2005 Ted "Smitty" Smith
128
G ROUNDING True 250.112 (H Copyright 2005 Ted "Smitty" Smith
129
G ROUNDING Exposed, non-current carrying, metal parts of equipment that is connected by cord and plug, regardless of voltage, that is installed in non- hazardous locations shall be grounded. True or False Copyright 2005 Ted "Smitty" Smith
130
G ROUNDING False 250.114 (1) and (2) Copyright 2005 Ted "Smitty" Smith
131
G ROUNDING The connection of a grounding electrode conductor or bonding jumper to fire-proofed structural steel shall not be required to be accessible if it is made with an irreversible compression connection. True or False Copyright 2005 Ted "Smitty" Smith
132
G ROUNDING True 250.68 (A) Exep. 2 Copyright 2005 Ted "Smitty" Smith
133
G ROUNDING A ground rod of 8 feet in length must be installed so that the connection point of the grounding electrode conductor remains accessible and above the ground. True or False Copyright 2005 Ted "Smitty" Smith
134
G ROUNDING False 250.53 (G) and 250.68 (A) Exp. 1 Copyright 2005 Ted "Smitty" Smith
135
E QUIPMENT U SE Handhold enclosure covers shall have an _____________________ that prominently identifies the function of the enclosure. Copyright 2005 Ted "Smitty" Smith
136
E QUIPMENT U SE identifying mark or logo 314.30(D) Copyright 2005 Ted "Smitty" Smith
137
G ROUNDING The ground fault current path of the equipment grounding system is intended to return fault current back to the earth. True or False Copyright 2005 Ted "Smitty" Smith
138
G ROUNDING False 250.2 Back to the source Copyright 2005 Ted "Smitty" Smith
139
F EEDERS AND B RANCH C IRCUITS Where calculations result in a fraction of an ampere that is less than __________, such fractions shall be permitted to be dropped. Copyright 2005 Ted "Smitty" Smith
140
F EEDERS AND B RANCH C IRCUITS.5 220.5(B) Copyright 2005 Ted "Smitty" Smith
141
F EEDERS AND B RANCH C IRCUITS Outlets for heavy duty lamp holders shall be calculated at a minimum of _______ volt-amperes. Copyright 2005 Ted "Smitty" Smith
142
F EEDERS AND B RANCH C IRCUITS 600 220.14(E) Copyright 2005 Ted "Smitty" Smith
143
F EEDERS AND B RANCH C IRCUITS A load not less than ___________ volt amperes shall be included for each 2-wire laundry branch circuit installed as required by 210.11(C)(2). Copyright 2005 Ted "Smitty" Smith
144
F EEDERS AND B RANCH C IRCUITS 1500 220.52(B) Copyright 2005 Ted "Smitty" Smith
145
F EEDERS AND B RANCH C IRCUITS An alternate load calculation for determine if the existing service or feeder is of sufficient capacity to serve additional loads in an existing dwelling unit is found in __________________. Copyright 2005 Ted "Smitty" Smith
146
F EEDERS AND B RANCH C IRCUITS 220.83 Copyright 2005 Ted "Smitty" Smith
147
F EEDERS AND B RANCH C IRCUITS The rules for calculating the load on fixed multi- outlet assemblies are found in _______________. Copyright 2005 Ted "Smitty" Smith
148
F EEDERS AND B RANCH C IRCUITS 220.14(H) Copyright 2005 Ted "Smitty" Smith