1
Induction of Anesthesia and Insertion of a Laryngeal Mask Airway in the Prone Position for Minor Surgery A&A Vol. 94(5) May 2002 R3 陳建宇
2
Methods 73 consecutive ASA physical status I–II patients Ambulatory surgery General anesthesia in the prone position Exclusion criteria: suspected airway difficulties, poor dentition, serious skeletal disease, history of gastroesophageal reflux, and lack of patient cooperation
3
Methods Prone position with pillows under the chest and the feet, allowing free anterior abdominal wall movement Hands were placed above the patient’s head, which was inclined to the left or right on a soft head ring When the patient was comfortable, standard monitors were applied
4
Figure 1. Before induction, the patient lies comfortably with her chest on two pillows and her feet on one pillow as shown
5
Methods O 2 6 L/min via face mask Fentanyl 1 µg/kg IV Propofol 2–4 mg/kg IV After loss of consciousness, the head ring was removed and the face mask was applied firmly with 100% oxygen
6
Methods Nondominant hand placed on the patient’s forehead turned slightly to the side and the assistant opening the mouth, the LMA was inserted As the LMA passed the incisors, the patient’s chin was released, allowing the tongue to fall forwards, thereby opening up the posterior oropharyngeal space for the LMA
7
Methods After inflation of the cuff, the head was carefully laid to the left or right onto the head ring Breathe spontaneously with nitrous oxide and sevoflurane in oxygen Antiemetic and additional opioid drugs were given as required for the specific operative procedure
8
Figure 2. Face mask applied to the patient’s face
9
Figure 3. Patient’s mandible pulled forward to allow insertion of laryngeal mask airway
10
Figure 4. Laryngeal mask airway in situ
11
Results Before induction, three patients with a short neck, one with a stiff neck, and one with sore breasts were assisted to repositioning themselves in the prone position until there was no discomfort All patients were easy to ventilate manually via the face mask One developed laryngospasm after insertion of the LMA and required additional propofol
12
Table 1. Patient Characteristics Data expressed as mean ± sd and range.
13
Table 2. Operative Details Duration expressed as median (range). EUA = examination under anesthesia.
14
Table 3. Cardiorespiratory MeasurementsData expressed as mean ± sd.MAP = mean arterial pressure; HR = heart rate; SpoMDNM2 = oxygenation saturation; RR = respiratory rate; ETcoMDNM2 = end-tidal carbon dioxide
15
Table 4. Problems Encountered LMA = laryngeal mask airway
16
Discussion Alternative method for providing anesthesia in the prone position for ambulatory surgery The difference between this method and others is that with the LMA it is possible to induce anesthesia in the prone position and maintain an unimpeded airway All complications encountered were minor and were amenable to routine management
17
Discussion After induction, the jaw and tongue fell anteriorly and were easy to ventilate manually via a face mask No problems were encountered with transient apnea One case of laryngospasm and nine cases of difficulty with insertion of the LMA The problems were attributable to inadequate depth of anesthesia and responded readily to additional increments of propofol
18
Discussion Malpositioning of the LMA occurred in four patients Three were resolved with simple readjustment of the position of the LMA One patient who was edentulous it was necessary for the anesthesiologist to hold the LMA in the correct position for the duration of the anesthetic
19
Discussion No rotatory displacement of the LMA because of head turning in the prone position Few episodes of oxygen desaturation and hypoventilation were resolved with manual ventilation via the LMA
20
Discussion Schebesta et al– (A method of spontaneously breathing anaesthesia in the prone position without endotracheal intubation. Anaesth Intensive Care 1991; 19) Nasopharyngeal airway Anesthesia was induced in the prone position for short surgical procedures Airway was inserted after induction and patients were allowed to breathe spontaneously
21
Discussion In comparison with the LMA, the nasopharyngeal airway is tolerated better at lighter levels of anesthesia However, there is additional pollution, dilution of inhaled anesthetics via oral entrainment and potential for nasal trauma With our method, there were two cases of bleeding related to soft tissue trauma to the airway by the LMA
22
Discussion Palmon SC et al— (The effect of the prone position on pulmonary mechanics is frame- dependent. Anesth Analg 1998; 87 ) (The effect of the prone position on pulmonary mechanics is frame- dependent. Anesth Analg 1998; 87 ) 77 adults undergoing mechanical ventilation Reduction in compliance occurred with the chest rolls and pelvis support placed laterally from chest to pelvis If there is restriction to movement of the abdomen in prone position, reduction of pulmonary compliance that can affect oxygenation and ventilation
23
Discussion Effect did not occur in our patient due to the relatively free abdominal movement provided by the two pillows supports Therefore, despite allowing patients to breathe spontaneously, oxygenation and ventilation were not adversely affected
24
Discussion Cardiovascular stability was maintained in our series of patients Although the prone position is not the standard position for inducing anesthesia, it is a position in which central venous cannulation, cardiopulmonary resuscitation, and semi-awake fiberoptic intubation have taken place
25
Discussion Success of the techniques require— Skill that comes from practice Confidence Knowledge that at any time it may be necessary to turn the patient supine for emergency management of any problems
26
Discussion Problems encountered were relatively minor— easily managed by increasing the depth of anesthesia and simple manual adjustment of the position of the LMA
27
Discussion Recommend the technique as an alternative method for anesthesiologists who will practice it on a regular basis This technique can be easily learned and practiced within approximately 10 supervised cases
28
Discussion A modification of our technique would involve the use of muscle relaxation and positive pressure ventilation via the LMA in the prone position As none of the patients required muscle relaxation for their surgery, we do not have data to support or discourage their use
29
DiscussionAdvantages– Rapid tracking of patients is essential in day surgery However, the prone position is required for additional time for preparation and recovery of patients In addition, the need to turn anesthetized patients requires extra operating room staff
30
Insertion of a Laryngeal Mask Airway in the Prone Position [ LETTERS TO THE EDITOR ] A&A A&A Volume 96(4) April 2003 Volume 96(4) April 2003
31
Does not wear gloves The LMA cuff does not appear to be adequately collapsed— may produce soft tissue trauma to the airway, induce laryngospasm and/or push down the epiglottis may produce soft tissue trauma to the airway, induce laryngospasm and/or push down the epiglottis
32
LMA does not secure— Dislodge due to gravity Squeezed up out of the pharynx when nitrous oxide diffuses into the cuff LMA should hold passively
33
LMA insertion than mask ventilation— Main disadvantages of propofol are apnea and airway obstruction LMA itself can provide a better airway than a conventional mask and oropharyngeal airway Vventilation via a face mask is not necessary during anesthesia induction with propofol without the use of muscle relaxants
34
No need of neck flexed and head extended— Tongue falls anteriorly by gravity Head slightly turned to the side or extended
35
Insertion of a Laryngeal Mask Airway in the Prone Position [LETTERS TO THE EDITOR] A&A A&A Volume 96(4) April 2003
36
No gloves needed— The technique did not require insertion of fingers into the patient’s mouth No contact with body fluids Wearing gloves may be considered optional
37
Soft tissue trauma— Any instrumentation of the airway in general anesthetic practice may cause soft tissue trauma and induce laryngospasm One of the purposes of submitting our paper for publication was to show that problems with the airway were minor and easily corrected
38
LMA was not secured in position— Not absolutely necessary to tie the LMA in position In prone position, the proximal end of the LMA and the connector were supported by the operating table
39
All patients were properly oxygenated— No difficulty ventilation Tongue falls forwards with gravity in the prone position, thereby opening up the posterior oropharyngeal space for the LMA Maintenance of the airway and insertion of the LMA were straightforward
40
We disagree with Dr. Bahk’s comment concerning the position of the head and neck. Whether or not the tongue falls forward with gravity, the head and neck should always be in an optimal position for insertion of an airway device; this is a hallmark of good anesthetic practice
41