Presentation is loading. Please wait.

Presentation is loading. Please wait.

Varitector VSSC – surge protection for I/O

Similar presentations


Presentation on theme: "Varitector VSSC – surge protection for I/O"— Presentation transcript:

1 Varitector VSSC – surge protection for I/O

2 Surge Protection ....for Power and I/O
SPD II & SPD III VARITECTOR VSPC VARITECTOR VSSC PLC Power protection Imax = 40kA (8/20μs) Pluggable arrestor module Local status indicator Contact for remote status alarm UL 1449 Edition 3 Signal protection Imax = 20kA (8/20μs) Pluggable arrestor module Local status indicator Group connection for remote status alarm UL 497B Signal protection Imax = 20kA (8/20μs) High density / low cost 4 or 6-terminal models Local status indicator (6 terminal option) UL 497B

3 VSSC ..............surge protection for I/O
What’s in a name ? Varitector = Variable Protector SSC = Signal Screw Connection VARITECTOR VSSC What is new? The 20+ year old DKU Series is being replaced with a new pluggable style/construction with more functionality. What approvals are there? UL is available now Class & Division and ATEX are planned for 2012. DK Series What is the availability? The new range includes more than 100 different articles. These are in stock – either in Richmond (high runners) or Detmold.

4 Where is I&C Surge protection used?
Industries where plant / signals are outside, e.g…. Sewage treatment plants Water treatment and pumping stations Chemical plants Refineries Customers are: Municipalities (+ their SIs) Plant end-users (above) Package plant OEMs (separators, dryers, coolers, effluent treatment, chemical dosing, pumping)

5 VARITECTOR SSC – Surge Protection for C&I
Screw connection: Torx-slot screw Cross section for 0.5mm² to 6mm² High tightening torque (0.8Nm) Easy to use:  Direct PE-contact by fit on the rail Two in one: Terminal block with integrated surge protection Space saving in the cabinet: only 6.2mm width per loop Approved to UL497B: High impulse current up to 20kA (8/20μs) and up to 2,5kA (10/350) to PE More than 100 variants:  current loop and binary signals  for 5V, 12V, 24V, 48V and 60V single components inside, e.g. MOV  Protection for data signals 4 pole & 6 pole options: VSSC4 is for basic functions VSSC6 includes TR and LD options

6 Basic functions

7 Basic functions – VSSC6 TR SL LD
Conductivity Probe (Switch) 0V 24V DC Power Supply

8 VSSC .......v. MTL MTL Surge Technologies: SD Series Bad:
No LED indicator option for status No marking space available Only 6 pole format Wire size up to 14AWG/2,5 mm² LP = $ (VSSC6 TR FG CL 24VAC/DC 0.5A = $60.49) Good: Direct PE- Connection Fuse / disconnect option for loop testing Function with colour code Wide approvals e.g. CSA, UL, ATEX, Installation size : 7 mm x 99 mm x 100 mm

9 S Signal type…? Analog, status, fieldbus, telecom
Selection step 1 What information do we need to be able to specify a product? Here is a guide. S Signal type…? Analog, status, fieldbus, telecom N Nominal voltage….? 12V, 24V, 48V, 60V, 120V, 230V…… I Indication of status needed…? Locally and /or Remotely F Frequency….? Fast-changing signals, Fieldbus or Telecom ? F Floating or Ground referenced…? Process measurement signals are often floating. Think….. S.N.I.F.F…. !

10 Questions?

11 Back-up slides

12 VSSC .........Typical customer questions
“I need surge protectors for 24V lines / signal lines / measurement loops / PLC inputs” “……… or for bus / RS485 / RS 422 / RS232 / telephone networks” “I’m looking for over-voltage / lightning / transient protectors for …..control loops” “I need some of your MTL / SD modules….. ” “……… or DK 4 U, DK 5 U, DK 6 U …or MCZ OVP”

13 Types of process I/O signals
Exc + Tx + - 2-wire transmitter Type K Thermocouple - Frequency Input, 3-wire RTD 3-wire Digital Input 3-wire transmitter Pwr Sig + 0v Tx Pot. 4-wire transmitter Pwr + Sig + 0v Tx Pwr - Analog Actuator Frequency Input, 2-wire Digital Actuator

14 Terminal sized surge protection
Slim line terminal for surge protection 4 and 6AN screw type connection Surge discharge via PE rail contact Double disconnect lever for test function Accessories: End plate 1,5 mm Frame for bigger parts 6,2mm Standard marker WS 10/5 middle / DEK5 / SnapMark 80 mm 88 mm Breite: 6,2 mm 55 mm 74 mm

15 Mechanical Data Screw: Torx / slot Torque: 0,8 Nm
Connection points 4AN Cross-section max. solid - 6mm² flexible - 4 mm² Stripping length 10 mm DIN Rail TS35 PE-Connection to TS 35 Protection class IP20 Housing Wemid black UL V0

16 Electrical Data Discharge current Imax up to 20kA
Voltage (Nom.) 5, 12, 24, 48 and 60V Current (series load) up to 26A Discharge via PE contact up to 20kA Monitoring (only for 6AN) 2 LED's Protection circuit for… Analogue signal Digital signal Temperature signal Floating Ground System 2 stage (GDT und TVS) 1 stage (GDT, MOV or TVS - parts)

17 Varitector SSC 6AN Easy to use for test functions:
 two disconnect lever to open the signal signal circuit Monitoring by LED:  Signal indication Easy to use:  Direct PE-contact by fit on the rail Easy handling for PE connection:  Two additional connection points for PE

18 Competition overview Weidmüller MTL Type SD Phoenix
Varitector SSC MTL Type SD Phoenix Type TT Dehn&Söhne Type DCO OBO Type MDP Connection 4 and 6 AN with Slot-Torx screw 6 AN screw 5AN tension clamp 4AN screw 5 AN tension clamp 8 AN screw PE-Contact to TS35 Yes No Easy to identify in the cabinet Yes, by different colours on the top marker Width 6,2mm 7mm 6mm 8,1mm Disconnection lever Yes for 6AN Compatible Design TERMOPTO and other terminals UK Series Monitoring 6AN Amount of variants 107 products from 5, 12, 24,48 up to 60V 18 products 5, 24, 48V 91 products from 5, 24, 48 and 60V 15 products from 12, 24, 48 and 60 9 products from 5, 24 and 48V ATEX variants 6 products 4 products 2 products 1 product none Floating ground products Impulse current max. 20kA 10kA 5kA Price position 100% 120% 110%

19 VSSC ..........v. Phoenix Contact TERMITRAB: TT-SLKK5 Bad:
Bad look-and-feel, if the products are assembled on the rail Worse connection to the DIN Rail Lateral off-set (S-Form) a single unit can not disassembled in a group of terminals Good: Compact size Approval: cRUus Installation size: 8 mm x 67,5 mm x 66,5 mm

20 VSSC ..........v. Phoenix Contact TERMITRAP: TT-EX(I)-24DC Bad:
The prints are not readable Good: Direct PE-Connection Approvals: cULus, Cl1 Div 2, KEMA 99ATEX5687X High torque possible Installation size : 6,2 mm x 79,6 mm x 54,6 mm

21 VSSC ........v. Dehn & Söhne DEHNconnect: RK… Bad:
Individual marking only on the top of the product Simple PE-Contact Terminal made by Wago Only tension clamp No approvals Only one ATEX-terminal: RK Ex (i)  DCO RK MD EX Good: Good readable print Installation size : 6 mm x 90 mm x 57 mm

22 VSSC .......v. OBO Bettermann MDP Bad:
Individual marking only on the top of the product Negative look-and-feel of the terminal Only tension clamp No approvals Only 3 parts: 5V, 24V, 48V Big installation size Good: Test under life with test unit “Life Control” 8 AN terminal Installation size : 8 mm x 100 mm x 99 mm

23 VSSC .......v. MTL MTL Surge Technologies: SD Series Bad:
No LED indicator option for status No marking space available Only 6 pole format Wire size up to 14AWG/2,5 mm² LP = $ (VSSC6 TR FG CL 24VAC/DC 0.5A = $60.49) Good: Direct PE- Connection Fuse / disconnect option for loop testing Function with colour code Wide approvals e.g. CSA, UL, ATEX, Installation size : 7 mm x 99 mm x 100 mm


Download ppt "Varitector VSSC – surge protection for I/O"

Similar presentations