Download presentation
Presentation is loading. Please wait.
Published byJosephine Whitehead Modified over 8 years ago
1
Electromagnetic Flow Meters Overview
2
Type M3000/M4000 / Type M1000 Type II / Type III Type ModMAG ® M2000 / Type B-MAG ™ I M5000 Type Food
3
Faraday´s law states that when a conductor (fluid) moves through a magnetic field of given strength, a voltage is produced. E = magnitude of the voltage B = magnetic field density D = pipe diameter v = average velocity of the medium Electrode Scoil Operating principle
4
. During the summer of the year 1831 Michael Faraday found the principle of induction. Already at that time he tried to measure the flow velocity of the river Thames. Unfortunately at that time without success. History
5
. The first working MAG meter was built in 1939 by the Swiss monk Bonaventura Thurlemann in the monastery of Engelberg in Switzerland. History
6
. Beginning of the 1950´s a Swiss company recognized the big advantage of the physical law of Faraday for flow metering and gave a research contract to the famous Batelle Institute in Geneva to develop a flow meter based on this basics. All existing meters on the market are still based on this first construction. In 1962 the first MAG was delivered to a Swiss water authority. History
7
Type M1000/1500 Type ModMAG ® M1000/1500 Type ModMAG ® M2000 Type ModMAG ® M3000/M4000 Type B-MAG ™ I M5000 Electromagnetic flow meters
8
. The low cost alternative Sizes:DN 6 to DN 200 Accuracy:±0,5% of actual flow > 0,5 m/s ±2,5 mm/s of actual flow ≤ 0,5 m/s Repeatability:0,1% Conductivity:> 5 µS/cm (demineralized water >20 µS/cm) Flow range:0,03 - 12 m/s Flow direction:Bidirectional Power supply: 24 VDC / 115 VAC / 230 VAC Display:LCD (4 lines and 16 digits) Blind version M1000 Housing:Powder coated aluminium in IP65 Ambient temp.:-20°C to 60°C ModMAG™ M1000 / M1500
9
. The low cost alternative Programming:3 buttons or by RS232 on M1000 In/Outputs:1 x analog 4 to 20 mA (active/passive) 2 x digital out (open collector, active/passive) 1 x digital in Interface:RS232 Empty pipe:Detection by third electrode Status:Min/Max. alarm, flow direction, error, empty pipe Preselection:Yes Low flow cut-of:0-10% Remote version:up to 100 m Detector types:Flange, Wafer, Food ModMAG™ M1000 / M1500
10
. The low cost alternative Special features:No Self diagnostic:Yes Verification device:No Special approvals:No ModMAG™ M1000 / M1500
11
. Applications - Water and waste water - Food and beverage - Power - Machines, trucks, OEM ModMAG™ M1000 / M1500
12
Type ModMAG ® M1000/1500 Type M2000 Type ModMAG ® M2000 Type ModMAG ® M3000/M4000 Type B-MAG ™ I M5000 Electromagnetic flow meters
13
. The universal meter Sizes:DN 6 to DN 2000 Accuracy:±0,25% of actual flow > 0,5 m/s ±1,25 mm/s of actual flow ≤ 0,5 m/s Repeatability:0,1% Conductivity:> 5 µS/cm (demineralized water >20 µS/cm) Flow range:0,03 - 12 m/s Flow direction:Bidirectional Power supply: 85 - 265 VAC / 9 - 32VDC Display:LCD (4 lines and 20 digits) Housing:Powder coated aluminium in IP67 Ambient temp.:-20°C to 60°C Electromagnetic flow meters
14
. The universal meter Programming:3 buttons (outside) In/Outputs:1 x analog 4 to 20 mA (active) 4 x digital out (open collector, active/passive) 1 x digital in Interfaces:ModBus ® RTU RS232/RS485, HART, Profibus DP, M-Bus Empty pipe:Detection by third electrode ModMAG™ M2000
15
Status:Min/Max. alarm, flow direction, error, empty pipe Preselection:Yes Low flow cut-of:0-10% Remote version:Up to 100 m Detector types:Flange, Wafer, Food ModMAG™ M2000 The universal meter
16
. Special features:Parameter backup via memory stick (in process)Data logging Firmware update via memory stick Self diagnostic:Yes Verification device:Yes Special approvals:No ModMAG™ M2000 The universal meter
17
. Applications - Water and waste water - Food and beverage - Power - Industrial - Others ModMAG™ M2000
18
Type ModMAG ® M1000/1500 Type ModMAG ® M2000 Type M3000 / M4000 Type ModMAG ® M3000 / M4000 Type B-MAG ™ I M5000 Electromagnetic flow meters
19
. The meter for hazardous areas Sizes:DN 6 to DN 600 Accuracy:±0,25% of actual flow > 0,5 m/s ±1,25 mm/s of actual flow ≤ 0,5 m/s Repeatability:0,1% Conductivity:> 5 µS/cm (demineralized water >20 µS/cm) Flow range:0,03 - 12 m/s Flow direction:Bidirectional Power supply: 85 - 265 VAC / 24 VDC Display:LCD (4 lines and 16 digits) Housing:Powder coated aluminium in IP67 Ambient temp.:-20°C to 60°C ModMAG™ M3000 / M4000
20
. The meter for hazardous areas Programming:3 buttons (inside and by magnetic stick) In/Outputs:1 x analog 4 to 20 mA (active) 4 x digital out (open collector, active/passive) 1 x digital in Interfaces:RS232 Empty pipe:Detection by third electrode Status:Min/Max alarm, flow direction, error, empty pipe Preselection:Yes Low flow cut-of:0-10% Remote version:Up to 100 m Detector types:Flange ModMAG™ M3000 / M4000
21
. The meter for hazardous areas Special features:No Self diagnostic:Yes Verification device:No Special approvals:M3000 ATEX Zone 2 /FM and CSA Class I Div II M4000 Div I ATEX Zone 1 / FM and CSA Class I Div I ModMAG™ M3000 / M4000
22
. - Chemical industry - Pharma - Oil and gas - Refining Applications ModMAG™ M3000 / M4000
23
Type ModMAG ® M1000/1500 Type ModMAG ® M2000 Type ModMAG ® M3000/M4000 Type B-MAG ™ I M5000 Electromagnetic flow meters
24
. Sizes:DN 15 to DN 600 Accuracy:±0,5% of actual flow > 0,5 m/s ±2,5 mm/s of actual flow ≤ 0,5 m/s Repeatability:0,1% Conductivity:> 20 µS/cm Flow range:0,03 - 12 m/s B-MAG™ I M5000 Battery-operated water meter
25
Flow direction:Bidirectional Power supply: Battery operated / Battery backup Battery life time up to 20 years Display:LCD Housing:Powder coated aluminium in IP67 Ambient temp.:-20°C to 60°C B-MAG™ I M5000 Battery-operated water meter
26
. Programming:3 buttons (outside) In/Outputs:4 x digital out (open collector, passive) Interfaces:ModBus ® RTU RS232, IrDA, M-Bus Empty pipe:Detection by third electrode Status:Min/Max alarm, flow direction, error, empty pipe Preselection:No Low flow cut-of:0-10% Remote version:Up to 30 m Detector types:Flange B-MAG™ I M5000 Battery-operated water meter
27
. Special features:Data logging with real time clock Self diagnostic:Yes Verification device:Yes Special approvals:OIML R49, CEN EN 14154 / ISO 4064, MI-001, MID in process B-MAG™ I M5000 Battery-operated water meter
28
. Applications - Water and waste water - Others B-MAG™ I M5000
29
Type Flange Type Wafer Type Food Electromagnetic flow meters
30
Flange connections:DIN, ANSI, JIS…. in C-steel or SS Sizes:DN 6 - 2000 Pressure rates:up to 100 bar Lining:DN 25 up to 2000Hard/Soft rubber DN 15 up to 600PTFE DN 300 up to 1400HALAR (ECTFE) DN 6 up to DN 10PFA Electrodes:Hastelloy C (standard) Tantalum Platinum/Rhodium Measuring, empty pipe, grounding electrodes Housing:C-Steel painted or stainless steel Lay lengths:Badger standard, ISO or customized Detector - Type Flange
31
Type Flange Type Wafer Type Food Electromagnetic flow meters
32
Flange connections: Sandwich Sizes:DN 25 - 100 Pressure rates:PN 40 Lining:DN 25 up to 100 PTFE Electrodes:Hastelloy C (standard) Tantalum Platinum/Rhodium Measuring, empty pipe, grounding electrodes Housing:C-steel or stainless steel Lay lengths:Badger standard Detector - Type Wafer
33
Type Flange Type Wafer Type Food Electromagnetic flow meters
34
Flange connections: DIN 11851, TriClamp ® BS 4825 / ISO 2852 Sizes:DN 10 - 100 Pressure rates:up to 16 bar Lining:DN 15 up to 100 PTFE DN 10 PFA Electrodes:Hastelloy C (standard) Tantalum Platinum/Rhodium Measuring, empty pipe, grounding electrodes Housing:Stainless steel Lay lengths:Badger standard Detector - Type Food
35
Thank You +44 (0)1280 817304 sales@bellflowsystems.co.uk www.bellflowsystems.co.uk Bell Flow Systems are the UK representative for Badger Meter.