DinBox DB65 Remote monitoring, alarming & control device Professional embedded SMS application
2
DINBox: universal GSM/GPRS Terminal and SMS Alarm Device 4 x Digital input (active/passive possible) 1 x Analogue input 0 - 4,8 Vdc 2 x Relais output Antenna FME 2 x RJ-45 for RS-232 AC/DC Powersupply 100-260Vac / 50-60Hz Optional backup batterie SMS / GSM / GPRS
3
DINbox DB65 as GSM/GPRS Terminal Unique feature Java embedded applications possible Write your own Java application and embedd this in the DINBox DB65 Support through MCS:
4
DINBox DB65 as Alarm Device Inclusive the integration with SMS Comfort backoffice software
5
Dinbox DB65: Inputs (Closing Contact) Push INPUT1 CLOSED SMS Email SMS
6
Dinbox DB65: Inputs (Opening Contact) Pull INPUT1 OPENED SMS Email SMS
7
Dinbox DB65: Inputs (Power Driven Input) + - 9Vdc INPUT1 CLOSED SMS Email SMS
8
Dinbox DB65: Inputs with time driven validity Push INPUT1 CLOSED Valid from 10.00-17.00 SMS Email SMS
9
Dinbox DB65: Inputs (Alarm Confirmation) ALARM1 SMS Email SMS Confirm ALARM1
10
Dinbox DB65: Input (Status reports) SMS Email SMS Input1 High Input2 Low Input3 Low Input4 High
11
Dinbox DB65: Inputs (Usage report) Send SMS when Input is 1000 min active SMS Email SMS
12
Dinbox DB65: Outputs (Closing & Opening Contact) SMS Email SMS Close Output 1
13
Dinbox DB65: Outputs (Closing & Opening Contact for specific duration) SMS Email SMS Close Output 1 5s s = seconds m = minutes h = hours d = days
14
Dinbox DB65: Outputs with time driven validity SMS Email SMS Close Output 1 Output only valid between 10.00 – 17.00 h
15
Dinbox DB65: Outputs (Closing & Opening Contact with SMS notification) SMS Email SMS DB65 OUTPUT 1 Closed confirmation SMS
16
Dinbox DB65: Outputs (Status report) SMS Email SMS DB65 OUTPUT 1 High OUTPUT 2 Low
17
Dinbox DB65: Outputs (Usage report) SMS Email SMS DB65 OUTPUT 1 1000 min. Send SMS when output is closed for 1000 min
18
Dinbox DB65: Keep Alive SMS Email SMS DB65 Loc. Brussels Installation 04498 Every week SMS I’m still alive
19
Dinbox DB65: Battery Alarm when Power Fails SMS Email SMS DB65 Main power fails Battery level 80 % BATT BATT Level 80 - 260 Vac MAINS
20
Dinbox DB65: Movement Detection SMS Email SMS DB65 Alarm Illigal movement detected. BATT
21