1 ODLAB The Graphite Block Acid Digestion System (ECO-PRE)

2 The existing digestion method’s sample digestion figures ODLAB The corrosion happen and sample contamination The harmful gas happen and loss. The unbalanced heating temperature

3 The digestion system’s component(basic) ODLAB Graphite hot block (OD-98-HP) Graphite block (OD-98-24Hole) Graphite block (OD-98-12Hole) Teflon digestion vessel (BaekDu™)

4 The material characteristics ODLAB Handmade controller(Acrylic) Teflon coated on the graphite block Corrosion proof (Teflon and graphite ) Sample digestion figure

5 The Teflon acid collection digestion vessel (BaekDu™)’s structure & principle ODLAB Heating Evaporation peak Falling Re-Evaporation Evaporation Circulation/Repetition Collection tube Digestion vessel Emission part

6 ④ ⑤ ⑦ ⑨ 210 ℃ ③ End 160 ℃ ② 170 ℃ 140 ℃ ⑧ 120 ℃ ⑥ ① ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑩ The digestion process for each sample and temperature/ time program

7 210 ℃ End 160 ℃ 170 ℃ 140 ℃ 120 ℃ The digestion time for each sample 90min 2~3hrs 3~4hrs 6~7hrs Jewelry Wastewater Fertilizer Filter Plant body Bionics Food Soil Compost Food Plastic Oil Marine sediment

8 The digestion vessel’s different type and size. ODLAB 1. 300ml 2. Brand new product 3. 3 different type vessels digestion vessel for work environment analysis 50ml(left) / 100ml(right)

9 The installation of the stirrer (for stirring with heating for 24ea samples simultaneously) ODLAB

10 The hexavalent chromium digestion(USEPA-3060A) ODLAB Measure Sample 2.5g accurately and place into acid digestion vessel Heated digestion solution 50ml at 90~95 ℃ (Dissolve NaOH20g+Na2CO330g in reagent water in a one- liter volumetric flask and dilute to the mark) Add magnesium chloride 0.4g into digestion vessel Add 0.1M phosphate buffer 0.5ml into digestion vessel. Heating and stirring (90 ℃ ~95 ℃ for 60minutes Filtering after air–cooled (Filter membranes 0.45um) 5minutes stirring after cover with the collection tube. Used 5.0M HNO3 for PH7.5 ± PH0.5 adjust Caution: If failure to meet between PH7.5 ± PH0.5 range, Necessitate redigestion of the samples. Digestion vessel cleaning with distillated water.

11 Application ODLAB  The soil aqua-regia digestion method according to the soil contamination official test method  The heat digestion method according to the food official test method -The sample quantity 5g digestion in the food for cd,pb analysis  The heating block digestion method according to the US-EPA3050  The hexavalent chromium elution digestion method according to the US-EPA3060A  The marine waste,sediment digestion according to the marine contamination official test method

12 ODLAB The recovery rate KRISS water parsley certified reference material(CRM) - plant body PbCd Certified value1.05ppm*0.066ppm Sample 11.048ppm0.068ppm Sample 21.047ppm0.067ppm Varian ICP-MS, Clean room, ultra high purity nitrogen acie14ml *This table is the reference value JSAC Plastic High level certified reference material(CRM) - polymer PbCdCr Certified value945ppm93.6ppm946.3ppm Sample 1957.4ppm88.6ppm902ppm Sample 2925.8ppm89.7ppm897.3ppm Perkin Elmer ICP,semi-conductor class nitrogen acid15ml, hydrogen acid 2ml, sulfuric acid2ml

13  Cadmium (Cd) : 0.288±0.009 mg/kg (Z-Score 0.15)  Lead (Pb) : 1.561±0.059 mg/kg (Z-Score 0.24) Certified value : 0.263±0.004mg/kg Certified Value : 1.463±0.025mg/kg The statistical interpretation for the analysis result

14 Result ODLAB

15 The product certification and safety policy ODLAB

16 Customer List ODLAB  National institute of environmental including analysis organization (Delivered 100places)  Seoul university,seonggyungwan university including 20universities  Research insitute of public health and environment & agricultural product quality management service (20places)  Forest research institute & food companies through Japan agency(25places)  Taiwan agency including southeast asia (6places)  Currently consult with Indo & Germany company agency