Presentation is loading. Please wait.

Presentation is loading. Please wait.

Neal T. Colwell, P.E. July 13, 2011. Stages of Agricultural Water Measurement SBx7-7 10,000 ac AB1404 2,000 ac Statements of Diversion & Use Measure &

Similar presentations


Presentation on theme: "Neal T. Colwell, P.E. July 13, 2011. Stages of Agricultural Water Measurement SBx7-7 10,000 ac AB1404 2,000 ac Statements of Diversion & Use Measure &"— Presentation transcript:

1 Neal T. Colwell, P.E. July 13, 2011

2 Stages of Agricultural Water Measurement SBx7-7 10,000 ac AB1404 2,000 ac Statements of Diversion & Use Measure & Report Deliveries to Individual Farms to DWR Measure Surface Water Diversions & Report to State Board

3 Requirements Overview Flow measurement devices must be used on all surface water diversions occurring on or after January 1, 2012

4 Requirements Overview Flow measurement devices must use:  “Best available technologies”; and  “Best professional practices” Unless not “locally cost-effective”

5 Requirements Overview Future statements must be submitted every three years for Riparian and Pre-1914 rights, or annually for license holders Statements after 2011 will be based on the flow measurements using such devices

6 Minimum Diversion Meter Device Requirements 1. Continuous measurement of total volume diverted 2. Recording of total volume to allow monthly reporting Note: Post-1914 Appropriative Water Rights may have additional requirements for measurement and reporting

7 Factors Influencing Device Selection Diversion type:  Closed pipe Siphon Pumped  Open channel Water characteristics:  Sediment content  Algae and aquatic plants Anticipated meter use (e.g., pump control)

8 Available Measurement Technologies For closed pipe:  Propeller, turbine, and paddle wheel  Magnetic (full-body & insertion)  Ultrasonic (insertion & strap-on)  Positive displacement For open channel:  Flumes  Weirs  Acoustic Doppler Require water level recording instrument

9 Examples of Measurement Technologies Magnetic Meters, Seametrics Propeller Meter, Linden County Water District

10 Ultrasonic Flow Sensor Reclamation District 2030, McDonald Island Examples of Measurement Technologies Data Recorder

11 Replogle Flume, USBR Water Measurement Manual H Flume, TRACOM Fiberglass Products Examples of Measurement Technologies

12 Rectangular Weir, Reclamation District 2030, McDonald Island Examples of Measurement Technologies Acoustic Doppler Installation, South San Joaquin Irrigation District

13 MACE USA, LLC South San Joaquin Irrigation District Examples of Secure Installations

14 Each Device has Particular Installation Requirements Uniform flow at device:  Straight pipe for closed pipe installations; or  Straight channel section for open channel installations Site power source:  Utility power;  Battery;  Solar with battery backup; or  Purely mechanical

15 Potential Range of Device Costs per Installation Closed PipeOpen Channel Ultrasonic: $5,500 - $9,000 per installation Flumes: $6,000 and up Varies with size Magnetic: $500/in-diameter full-body $5,500 insertion (clean water only) Weirs: $6,000 and up Varies with size Propeller, Turbine/Paddle (clean water only): $1,500 to $4,000 and up Acoustic Doppler: +/- $40,000 Site conditions, data storage, and data transmission methods will dramatically influence installation cost.

16 Installation Planning If “locally cost-effective” discussions do not result in lower cost alternatives, then:  Reporting Requirements: Needs to be active before any discharges that occur in 2012.  Schedule: Allow for at least four weeks for delivery and installation.  Permitting: May require County permits, particularly for utility power.  Water Shut-off: May require shutting off water supply for one day or more.

17 For More Information Attend July 21, 2011 Water Diversion Measurement Public Workshop Download KSN Flow Measurement Resource Guide www.ksninc.com

18 For More Information Contact KSN for additional site-specific information: Kjeldsen, Sinnock & Neudeck Inc. www.ksninc.com Neal Colwell, P.E. (209) 946-0268 ncolwell@ksninc.com