Download presentation
Presentation is loading. Please wait.
Published bySophia Booker Modified over 8 years ago
1
1 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ In-situ measurement of the hydrogen content of a-C:H Layers with Laser-induced Thermal Desorption F. Irrek, B. Schweer, S. Brezinsek, A. Pospieszczyk V. Philipps, U. Samm
2
2 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ T-Inventory of a Fusion Reactor Graphite for high heat-flux areas Erosion and Redeposition of Carbon Formation of Hydrogenated Carbon Layers – Hydrogen Retention Max. Tritium Inventory (Safety Limit) in ITER: 350 g Diagnostics for in-situ Measurement of retained Tritium needed A. Kirschner
3
3 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Hydrogen Measurement by Means of Laser Desorption and Emission Spectroscopy In-situ measurement at plasma-wetted surfaces Rapid surface heating Release of D 2, H 2, HD, CD 4, C 2 D 4 Emission spectroscopy: H , D 2 -Fulcher n e, T e measured by other diagnostics Calibration at TEXTOR with previously coated and characterized samples
4
4 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Power Density and Temperature 1-dim Heat Conduction sufficient for Spot Centre: Restrictions: 1.Temperature 1300…2000 K 2.Laser spot size 4 … 6 mm 2 Laser power on surface < 14 kW 3.Pulse Length < 4ms Laser-Desorbed Spot ( a-C:D on Graphite) Temperature Rise T [kK] 0 3 2 1 Laser Pulse Duration t [ms] 0.20.5 1 247 T [K] 0 1000 2000 Heat Load [kW/cm 2 ]
5
5 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Thermal Desorption of a-C:H Layers Number of Released Particles normalized Temperature in centre of laser spot [K] Released Particles after laser shotParticle flux (Time derivative) laser heating 10 6 K/s Heating in oven 1 K/s Different configurations of C-atoms graphitic (sp 2 ) aromatic (sp 2 + H) alkane-like (sp 3 + nH) [*] J. Küppers – Surf. Sci. Reports 22 (1995) 249 Ref: [*]
6
6 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ depends on Substrate Properties and Layer Properties (damping and refractive index) Reflexion of Laser Light from the Surface P. Wienhold Refractive Index of Layer depends on H content A. Annen
7
7 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ D Release: Pressure Rise 250 nm a-C:D Layer >80% Reduction of released D Flow in 2 nd Shot Applied mean Laser Power Density: 95 kW/cm 2 D 2 -Flow peaks below 1000 °C D 2 : CD 4 = 17 CD 4 D2D2 1 st shot: 6x10 14 2 st shot: below detection limit 1 st shot: 1x10 16
8
8 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ 1 2 3 4 Layer Centre Border Centre Border 4 3 12 Inventory / a.u. Spot 1.2 mm D Release: SIMS SIMS Measurement: Hydrogen Inventory in Sample Surface 96% Reduction of D-Inventory, Charcoal-like Spot Surface H from reabsorbed H 2 O
9
9 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Heating, Surface Effects Rapid Heating: –1300…2000 K reached by 70 kW/cm 2 x 1.5 ms irradiation Target substrate + roughness Layer optical properties: thickness, H/C Short-time Outgassing Flux (0.2 ms): –H 2, CH 4, 4:1 – 8:1 –~10 18 Molecules/(cm 2 nm s) Inevitable Consequences: –Thermal Cracks in substrate –Formation of Blisters: Thermal stress and loss of adhesion –Sublimation of Blisters: 1 µm 3 of material Absorption > 10 -5 during last 0.1 ms is sufficient View 20° to surface
10
10 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ LDS measurements in laboratory: Principle Sample 10 cm Nd:YAG-Laser 1064 nm, 1.5 ms x 70 kW/cm 2 QMA112 Photodiode Reflected Laser light Repititive Mass scan (1 Hz) of mass 2 to 50 Before and after laser pulse Total duration 51 s
11
11 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ LDS measurements in laboratory: Principle Superimposed mass spectra from laser desorption (here: thick soft co-deposit from old ALT tile) Dark lines: early Bright lines: late 4 3 2 18161412 2028
12
12 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ LDS measurements in laboratory: Principle Superimposed mass spectra from laser desorption here: Graphite sample, coated in PADOS (360 nm), Dark lines: early Bright lines: late Before Textor exposure Total D: 1.5 x 10 17 H 2 /D 2 : 0.16 D 2 /CD 4 : 6.0 After Textor exposure (3 units) Total D: 6.6 x 10 16 H 2 /D 2 : 0.39 D 2 /CD 4 : 11
13
13 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ LDS measurements in laboratory: Data evaluation m=2 U=0.203 V m=3 U=0.368 V m=4 U=0.518 V 1.Extract mass channels 2.Plot over time 3.Fit exponential before and after laser pulse 4.Return Voltage difference of fit curves at time of laser pulse 5.Apply Calibration factors (H 2, CH 4 & Isotopologues) and sum up relevant channels N D, N H, H/D, D 2 /CD 4
14
14 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Emission Spectroscopy Radial Position / cm rel. Toroidal Position / cm DD Intensity / a.u. 49 46 48 47 I tot 321010-2 Sample Conversion from spectral line intensity I tot to atomic flux A Electron density n e [10 18 m -3 ] 1 3 10 0 20 40 60 80 100 Electron Temperature T e [eV] S/XB (T e,n e ) Electron density n e [10 18 m -3 ] 1 3 10 0 20 40 60 80 100 Electron Temperature T e [eV] S/XB (T e,n e )
15
15 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Radial Position toroidal Measurements at TEXTOR: Principle diamater = 11 cm HH H2H2 48474649 Radial Position / cm Toroidally Integrated Signal H x 5% H2H2 toroidal 49 46 48 47 Sample Surface
16
16 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Time: 1 ms/Frame Frames before and after Pulse = Background Signal w/o Background Integrated Signal, Background subtracted Measurements at TEXTOR: Data evaluation Lorentz Fit Area Width Position of Maximum
17
17 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Measurements at TEXTOR: Overview by shot Shot#Filter D+H/cm 2 /10 18 D:HD 2 :CD 4 Raw Single frames Scaled signal 102549HH 0.03 0.71:3 102550CH1 102551H2H2 1 0.61:2 102552C II 1 102553HH 1 75:16:1 102554HH 0.1 r = 49 cm (2 nd Laser Pulse) 1 st 2 nd
18
18 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Shot#Filter D+H/cm 2 /10 18 D:HD 2 :CD 4 Raw Single frames Scaled signal 102555C2C2 1 0.41:2 102556C2C2 0.1 102557HH 0.05 0.63:1 102558CH1 102559C2C2 0.1 2.25:1 102560C II 1 r = 49 cm Measurements at TEXTOR: Overview by shot
19
19 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Shot#Filter D+H/cm 2 /10 18 D:HD 2 :CD 4 Raw Single frames Scaled signal 102564H2H2 13.24:16 102565HH 0.1 1.94:17 102566HH 0.03 r = 50 cm 49 cm Measurements at TEXTOR: Overview by shot
20
20 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Measurements at TEXTOR: Overview H Shot#Filter D+H/cm 2 /10 18 D:HD 2 :CD 4 Raw Single frames Integral / V x pixel 2 102549 HH 0.030.71:314400 1025531 75:16:1 1025540.1 1025570.050.63:133400 1025650.1 1.94:17:1 1025660.0329400 r = 49 cm 2 nd Laser Pulse 1 st 2 nd r = 50 cm
21
21 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Measurements at TEXTOR: Overview H 2, CH, C 2 Shot#Filter D+H/cm 2 /10 18 D:HD 2 :CD 4 Raw Single frames Integral / V x pixel 2 102551 H2H2 10.61:294 10256413.24:16430 102550 CH 10.71:3105 10255810.63:1252 102555 C2C2 1 0.41:2 1025560.1118 1025590.12.25:1 870 r = 49 cm
22
22 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Approx. 20 free spots on 8 old samples Coating of 9 samples scheduled for beginning of next week –Non-polished samples –360 nm (effective thickness / on Silicon) –Coated side clearly marked –Characterized with LDS prior to TEXTOR exposure Presently ready samples
23
23 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Sample surface at 48 cm 7 x 10 16 D+H 49 cm 6 x 10 16 D+H 50 cm 6 x 10 16 D+H Measurements at TEXTOR: H 46 47 48 49 50 Radial Position r / cm 51305040 5090 FWHM: 3.3 cm FWHM: 5.3 cmFWHM: 2.0 cm Total:6 100 46 47 48 49 50 46 47 48 49 50 HH HH HH
24
24 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Measurements at TEXTOR: H 2 1.4 x 10 18 (H+D)/cm 2 53 normalized raw 50 cm 47
25
25 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Summary Laser-induced heating and thermal desorption: –Power density of 70 kW/cm 2 for 1.5 ms –Complete desorption at 1400 … 1600 K –Release of H 2, CH 4, C 2 H 4 (75:15:10) Spectroscopic measurement with Interference filters: –H : S/XB, H atom per released molecular species –H 2 (Fulcher-Band): D/XB, amount of H released as H 2 (60%)
26
26 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Measurements at TEXTOR: H 102549: Filter: 3%, H N D+H = 0.7 x 10 18 /cm 2 D:H = 1:3 102557: Filter: 5%, H N D+H = 0.6 x 10 18 /cm 2 D:H = 3:1 2400 Integral/ND-Filter: 14400 V x pixel 2 Integral/ND-Filter: 33400 V x pixel 2
27
27 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Measurements at TEXTOR: H 102566: Sample at 50 cm Filter: 3%, H N D+H = 1.9 x 10 18 /cm 2 D:H = 4:1 102557: Filter: 5%, H N D+H = 0.6 x 10 18 /cm 2 D:H = 3:1 Integral/ND-Filter: 33400 V x pixel 2 Integral/ND-Filter: 29400 V x pixel 2
28
28 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Measurements at TEXTOR: H 2 102551: Filter: 100%, H 2 N D+H = 0.6 x 10 18 /cm 2 D:H = 1:2 102564: Filter: 100%, H 2 N D+H = 3.2 x 10 18 /cm 2 D:H = 4:1 Integral: 94 V x pixel 2 Integral: 430 V x pixel 2 Different penetration depth?
29
29 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Measurements at TEXTOR: C 2 102556: Filter: 10%, C 2 N D+H = 0.4 x 10 18 /cm 2 D:H = 1:2 102559: Filter: 10%, C 2 N D+H = 2.2 x 10 18 /cm 2 D:H = 5:1 Integral/ND-Filter: 118 V x pixel 2 Integral/ND-Filter: 870 V x pixel 2
30
30 Florian Irrek, GRK1203-Seminar in Bad Breisig 11.10.2007 Forschungszentrum Jülich in der Helmholtz-Gemeinschaft Institut für Energieforschung – PlasmaphysikAssociation EURATOM - FZJ Measurements at TEXTOR: CH 102550: Filter: 100%, CH N D+H = 0.7 x 10 18 /cm 2 D:H = 1:3 102558: Filter: 100%, CH N D+H = 0.6 x 10 18 /cm 2 D:H = 3:1 Integral: 105 V x pixel 2 Integral: 252 V x pixel 2