1 Video Entry System with Self-Learning
X1 SYSTEM Video Entry System with Self-Learning Power Supply Included BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

2 X1 SYSTEM X1 System Key Assets
Two single non-polarised wires, power supply included Simpler installation Expandability Reduced number of dedicated devices Use of various types of cable BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

3 X1 SYSTEM X1 System Features
Inherits all the features of the X2 system 4 inputs 100 calls* 8 receivers in simultaneous call Programming for self-learning B/W or colour video signals still on twisted pair with power supply Intercom function Perfect integration with system 300 for complex structures * 64 calls with analogue plate, 100 with digital plate BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

4 X1 SYSTEM X1 System Features
Guaranteed Functions Secrecy of speech Door lock release Auxiliary services Self-connection of entry panels Personal doorbell Call warning Door lock release time setting System busy indication BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

5 X1 SYSTEM NC/321GR – NVM/301GR YKP/301-YV XDV/304 YKP/301-YV OPHERA
VA/301 HEV/301ST – HEP/306ST VCM/1D TWISTED CABLE POWER SUPPLY BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

6 X1 SYSTEM VCM/1D Description
Composed of 2 cables: Twisted in such a way as to render the signal less sensitive to disturbances Tin-plated in such a way as to avoid oxidations Cable cross-section: 1 mm2 Using the VCM/1D cable ensures that the system achieves its greatest performance. For a system with 64 calls, without signal repeaters, the following can be attained 100m distance between entry panel and last receiver* 600m of total stretched cable* * VCM/2D + VCM/1D BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

7 X1 SYSTEM System Performance
System with 64 Lynea-type receivers Type of cable Max distance between plate > VA/301 Max distance between VA/301 > monitor Max distance between plate > monitor Total stretched cable VCM/1D 0-100m * 0-100m 100m 600m UTP/5 (AWG24-0.2mm2) 0-25m 400m Tel. twisted pair (0.28mm2) 0-30m 250m Symmetrical pair cable (1mm2) * Plus two conductors of 1 mm2 BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

8 X1 SYSTEM System Performance
System with 20 Lynea-type receivers Type of cable Max distance between plate > VA/301 Max distance between VA/301 > monitor Max distance between plate > monitor Total stretched cable VCM/1D 0-100m * 0-150m 200m 600m UTP/5 (AWG24-0.2mm2) 0-30m 130m 400m Tel. twisted pair (0.28mm2) 0-50m 150m 250m Symmetrical pair cable (1mm2) 0-100m * Plus two conductors of 1 mm2 BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

9 X1 SYSTEM System Performance
System with Lynea-type receiver Type of cable Max distance between plate > VA/301 Max distance between VA/301 > monitor Max distance between plate > monitor Total stretched cable VCM/1D 0-100m * 0-150m 250m / UTP/5 (AWG24-0.2mm2) 0-40m 140m Tel. twisted pair (0.28mm2) 0-50m 150m Symmetrical pair cable (1mm2) 0-100m 200m * Plus two conductors of 1 mm2 BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

10 X1 SYSTEM VA/301 Power supply unit capable of supplying power direct to receivers from the X1 bus with a single twisted pair. Furthermore, it has a separate output for supplying power to an entry panel and any accessories. Dimensions: 12 DIN It is possible to extract the X1 signal with power supply at +24V DC (in order to be used in the XUp system) from the CN1 connector. BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

11 X1 SYSTEM VA/301 TECHNICAL FEATURES: Receiver power supply 20 V DC
One VA/301 can supply: 1 entry panel, analogue or digital, with 64 calls at most 1 activated X1 video entry system receiver and up to 63 in stand-by Simultaneous call receivers: 8 (3 full call, or 2 in full call and 6 with reduced note) If video entry systems 7 are supplied locally. BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

12 X1 SYSTEM UP TO 4 INPUTS VCM/1D VA/301 Twisted Pair + 2 Cables for Power Supply 1 2 3 4 HEV/301 KHSO ..KHPS(KHPD) .. HEP/306 Power to the Entry Panels after the first one is supplied appropriately BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

13 X1 SYSTEM Entry Panels: X1 Vs X2
From 1 to 64 calls: 1 (1 VA/301) 12 DIN mod. From 1 to 8 calls: 1 From 9 to 64 calls: 2 (1 VA/ VAS/100) 24 DIN mod. From 1 to 64 calls: 2 (1 VA/301 + 1 VAS/100) From 1 to 8 calls: 2 1 VAS/100.20) From 9 to 64 calls: 3 2 VAS/100.20) 36 DIN mod. X2 SYSTEM From 1 to 20 calls: 1 (1 VAS/100.20) From 21 to 64 calls: 2 (2 VAS/100.20) From 1 to 20 calls: 2 From 21 to 64 calls: 3 (3 VAS/100.20) BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

14 X1 SYSTEM PROGRAMMING Connect the System to a Power Supply
Wait for the confirmation note. The number of tones also indicate the number of entry panels. Reposition the SW1 jumper. Work on the last entry panel. Remove the SW2 jumper Remove the SW1 jumper BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

15 X1 SYSTEM PROGRAMMING Lift the handset of the first receiver to be programmed Replace the handset; Repeat the operations from point 7 on all receivers Press and hold down the door lock release and auxiliary two buttons at the same time until sound to the entry panel is activated Re-insert the SW2 jumper From the entry panel press the call button to which the receiver is connected BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

16 X1 SYSTEM SIMULTANEOUS CALLS
Up to 8 in simultaneous call. 2 in full call and 6 reduced or 3 in full call OPHERA OPHERA 1 2 5 OPHERA VA/301 Two wires for power supply HEV/301 VAS/100 VCM/1D KHSO ..KHPS(KHPD) VCM/2D .. HEP/306 BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

17 X1 SYSTEM VSE/301 The selector is used to connect groups of intercom receivers (max. 10 Exedra series, max. 6 Lynea series, 8 Ophera) and the main line of an X1 system, X2 or system 300. The selector is able to supply power direct to the intercom receivers from the X1 bus with a single twisted pair. SW2 Jumper Function (absent in the VSE/300; the reset of the intercom facility appened each times the jumper SW came removed) It is generally inserted. It is removed (for at least 5 secs) to restore the default conditions BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

18 X1 SYSTEM VSE/301 TECHNICAL FEATURES:
Used to add or replace an intercom receiver without having to programme all receivers again in the VSE/301 Receiver power supply through bus: 20 V DC DIMENSIONS: 8 DIN (instead 10 DIN, 6 DIN VSE/ DIN AS/200) One VSE/301 supplies power to: 1 intercom receiver 10 receivers in simultaneous call - all in full call (if video entry phones 9 are supplied separately) BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

19 X1 SYSTEM INTERCOM 1 2 5 OPHERA VSE/301 VA/301 Two wires
for power supply HEV/301 KHSO VAS/100.20 VCM/1D ..KHPS(KHPD) .. HEP/306 VCM/2D BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

20 X1 SYSTEM INTERCOM Intercom function between 2 and 4 4 3 1 1/a 2
OPHERA 1 1/a 2 VSE/301 AS/200 VA/301 Two wires for power supply HEV/301 VCM/1D KHSO ..KHPS(KHPD) VCM/2D .. HEP/306 BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

21 X1 SYSTEM VSE/301 Programming
Remove the SW1 jumper From the receiver that you want to programme press the call button with which you want to call and wait for the 3 confirmation notes Repeat the operation in the previous point for all intercom receivers Press AUX 2 for receivers that are not intercommunicating Exit the programming repositioning the SW1 jumper VSE/301 programming will be carried out after programming the calls to the receivers BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

22 X1 SYSTEM XAS/301 TECHNICAL FEATURES:
Audio, video and data repetition units for X1 lines, allow the system to be extended in terms of distance and n° units. As with the VA/301 it supplies power from the bus to supply the receivers. XAS/301 WILL BE INSERTED UPRIGHT IF AT LEAST ONE OF THE FOLLOWING CHARACTERISTICS IS EXCEEDED: 64 USERS 100m MAX DISTANCE BETWEEN ENTRY PANEL AND LAST RECEIVER 600m TOTAL STRETCHED CABLE 2 XDV/300A 16 XDV/304A IN SERIES 30 between XDV/304A and XDV/304 After XAS/301 it is possible to replicate the above-mentioned characteristics with the possibility to reach a maximum 100 users (maximum n° of users managed by the entry panel) BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

23 X1 SYSTEM RECEIVERS Lynea Nova Ophera
The receivers set to be supplied directly by the bus are: Lynea Nova Ophera BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

24 X1 SYSTEM RECEIVERS It is possible using a jumper to decide if the receiver must be supplied locally or directly by the bus. The possible positions of the jumper are described by the label shown below: WARNING: If X1 receivers are used in X2 systems without the jumper being set correctly (local supply) the system enters into protective state, locking itself. BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

25 X1 SYSTEM X1 DEVICES BPT S.p.A. Via Roma,41
LYNEA SERIES YKP/301 Entry phone with wall mounting for video modules YV and YVC NOVA SERIES NVM/301GR Colour monitor module, grey 2” LCD NVM/301BB Colour monitor module, white 2” LCD NS/61 NVM/301 + NC/321 mounting for 6 module embedding box NST/61 Table-top mounting for Nova POWER SUPPLIERS VA/301 230V 50/60Hz power supplier, 12 unit module for DIN rail, low profile XAS/301 Additional 230V power supplier for signal regeneration SELECTORS VSE/301 Intercom selector, integrated power supply, 8 unit module for DIN rail, low profile CONNECTION CABLES VCM/1D Tin-plated 2 conductor cable, 1mm cross-section in 100m coil VCM/1D/500 Tin-plated 2 conductor cable, 1mm cross-section in 500m coil BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

26 X1 SYSTEM X1 KIT LYNEA KIT/00 LYNEA KIT/01 OPHERA KIT/00 OPHERA KIT/01
NOVA KIT/00 NOVA KIT/01 NOVA KIT/02 NOVA KIT/03 All kits comprise the Receiver indicated in the name plus the VA/301 power supplier and the Targha series GREYHOUND Entry Panel BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

27 X1 SYSTEM X1 OPHERA KIT BPT S.p.A. Via Roma,41
30020 Cinto Caomaggiore (VE) Italy

28 X1 SYSTEM X1 LYNEA KIT BPT S.p.A. Via Roma,41
30020 Cinto Caomaggiore (VE) Italy

29 X1 SYSTEM X1 NOVA KIT BPT S.p.A. Via Roma,41
30020 Cinto Caomaggiore (VE) Italy

30 X1 SYSTEM SYSTEM EXPANSION
Block-type installations Up to 2000 users Porter switchboard Customisable parameters 64 Blocks 64 Users per block 64 Main Entry Panels Simply integrating the X1 system with the powerful S300 BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

31 X1 SYSTEM BCK X1 BCK X1 OPHERA VCM/1D VCM/2D VCM/4D TWISTED PAIR
NC/321-NVM/301-NS/61 VCM/1D VCM/2D VCM/4D XDV/304 XDV/304 TWISTED PAIR YKP/301-YV YKP/301-YV VA/301 VA/301 BCK X1 BCK X1 HEV/301 HTS HAC/X2LR HAC/300LR XDV/304A HEV/301 XAV/300 RIR/300LR KHSO ..KHPS(KHPD) .. HEP/306 XA/300LR ICB/300 BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy

32 X1 SYSTEM Receiver current demand X2 Entry Panel current demand
YV 350 mA Nova 220 mA Ophera 400 mA X2 Entry Panel current demand HEV/ mA HAC/300LR 350 mA Supply: VAS/ V 1.7A AS/ V AC V DC 600mA mA BPT S.p.A. Via Roma,41 30020 Cinto Caomaggiore (VE) Italy