1 FACULTY OF ENGINEERING TECHNOLOGY AND RESEARCH
MATERIAL BALANCE Guided by Mr. Pratik B. Patel Prepared by Sr. No PEN Name 1 Bhadja Jitenkumar C. 2 Dankhara Nikunj D. 3 Gajera Vivek G. 4 Gajera Zavin R. FACULTY OF ENGINEERING TECHNOLOGY AND RESEARCH

2 Process Classification
Chemical processes can be classified as batch, continuous or semi-batch and as either transient or steady state Batch process is one in which the feed is charged into the system at the beginning of the process, and the products are removed all at once some time later Continuous process is when the inputs and outputs flow continuously across the boundaries throughout the duration of the process. Semi-batch process is a process in which its inputs are nearly instantaneous but the outputs are continuous or vice versa If the values of all process variables in a process do not change with time, the process is said to be operating at steady state. If any changes with time, transient or unsteady state operation exists

3 One of the main responsibilities of chemical engineers is to create/construct/ analyse chemical processes (or, at least, to understand the existing processes) The layout of a chemical process is called “process flow sheet (PFS)” or “process flow diagram (PFD)” PFS or PFD can be for just a single process unit or for the whole process, either simple or complicated process.

4 PFD for a water-softening by ion-exchange process
Examples of PFS or PFD PFD for a water-softening by ion-exchange process

5 Normally, a PFS or a PFD comprises: • All major process equipments/units • Lines entering or leaving the process/unit and/or lines connecting two or more process equipments/units (these lines are called “streams”) • Flow rate of each stream • Composition of each stream • operating conditions of each stream and/or unit/equipment (e.g., T, P) • Energy/heat needed to be added to and/or removed from any particular part of the process or the entire process

6 Some important symbols of process equipments

7 Material balance are based on : Law of Conservation of Mass
The law states that mass can neither be created nor destroyed Material balance equations are the manifestation of the law TOTAL MASS INPUT = TOTAL MASS OUTPUT The design of a new process or analysis of existing one is not complete until it is established that the inputs and outputs of the process satisfy the material balance equation.

8 Material Balance Equation
Suppose methane, is a component of both input and output of a process If the flow rates of input and output are found to be different. Possible explanations are .… methane is leaking methane is consumed or generated in a reaction methane is accumulating in the process vessel wrong measurement qin(kg CH4/h) qout(kg CH4/h) Process unit

9 General Material Balance Equation
A balance on a material in a process system may be written as: Input + generation - output - consumption = accumulation The equation may be written for any material that enters or leaves any process system It can be applied to the total mass or total moles of this material or to any atomic species involved in the process

10 EXAMPLE: The General Balance Equation
Each year 50,000 people move into a city, 75,000 people move out, 22,000 are born, and 19,000 die. Write a balance on the population of the city. SOLUTION Let P denotes people: Input + generation - output - consumption = accumulation Each year the city's population decreases by 22,000 people.

11 Two types of balances may be written for any system;
differential balances and integral balances Differential balances indicate what is happening in a system at an instant of time. Each term is a rate and has a unit of quantity unit per time Integral balances describe what happens between two instant of time. Each term of the equation is an amount of the quantity with a corresponding unit

12 Balances on Steady- State Processes
The process is said to be operating at steady-state when all process variables do not change with time. The accumulation term in a balance must equal to zero to ensure that the amount/mass of material in the process do not change with time STEADY STATE means ACCUMULATION = 0 Input + generation - output - consumption = 0 Input + generation = output + consumption The generation and consumption terms are applied only when chemical reaction is involved if there is no reaction, Input =output

13 Balances on Steady- State Continuous Processes (Continuous Distillation Process)
One thousand kilograms per hour of a mixture of benzene (B) and toluene (T) containing 50% benzene by mass is separated by distillation into two fractions. The mass flow rate of benzene in the top stream is 450 kg B/h and that of toluene in the bottom stream is 475 kg T/h. The operation is at steady state. Write balances on benzene and toluene to calculate the unknown component flow rates in the output streams.

14 rate of input = rate of output
no reaction, rate of input = rate of output

15 EXAMPLE: Balances on a Batch Mixing Process
Two methanol-water mixture are contained in separate flasks. The first mixture contains 40 wt % methanol, and the second contains 70% methanol. If 200 g of the first mixture are combined with 150 g of the second, what are the mass and composition of the product.

16 Flowchart Draw a flowchart of the process, using boxes or other symbols to represent process units (reactors, mixers, separation units, etc.) and lines with arrows to represent inputs and outputs. 100 mols/hr C2H6 2000 mols/hr Air 0.21 mol O2/ mol 0.79 mol N2/ 2100 0.0476 C2H6/ 0.200 0.752

17 The chart must be fully labeled with values of known variables at the locations of the streams
For example a stream contains 21 mole % O2 and 79%N2 at 320ºC and 1.4 atm flowing at a rate 400 mol/h might be labeled.

18 the total amount or flow rate of the stream and the fractions of each component,
Or directly as the amount or flow rate of each component.

19 Assign algebraic symbols to unknown streams [such as ṁ (kg solution/min), x (lbm N2/lbm), and n (kmol C3H8)] and write their associated units on the chart

20 When labeling component mass or mole fractions of a stream the last one must be 1 minus the sum of the others. If you are given that the mass of stream 1 is half that of stream 2, label the masses of these streams m and 2m rather than ml and m2; if you know that there is three times as much nitrogen (by mass) in a stream as oxygen, label the mass fractions of O2 and N2 y(g O2/g) and 3y(g N2/g) rather than yl and y2. If a volumetric flow rate of a stream is given, convert to mass or molar flow rate since balances are not normally written in volumetric quantities

21 Degree of Freedom Analysis
Draw and label flow chart Count the unknown variables on the flow chart, nunknowns Count the independent equations relating them, nindep eqns ndf = nunknowns - nindep eqns If ndf = 0, the problem is solvable If ndf>0, the problem is underspecified, need to provide more information/equations. If ndf˂0, the problem is overspecified, more equations than unknowns, redundant and possibly inconsistent information.

22 A: Liquid water, fed at a rate of 20.0 cm3/min
An experiment on the growth rate of certain organisms requires an environment of humid air enriched in oxygen. Three input streams are fed into an evaporation chamber to produce an output stream with the desired composition. A: Liquid water, fed at a rate of 20.0 cm3/min B: Air (21 mole% O2, the balance N2) C: Pure oxygen, with a molar flow rate one-fifth of the molar flow rate of stream B. The output gas is analyzed and is found to contain 1.5 mole % water. Draw and label a flowchart of the process, and calculate all unknown stream variables. Dr.Riham Hazzaa

23

24 Flowchart Scaling and Basis of Calculation
The procedure of changing the values of all stream amounts or flow rates by a proportional amount while leaving the stream compositions unchanged is referred to as scaling the flow chart. Scaling up: if the final stream quantities are larger than the original quantities, Scaling down: if they are smaller.

25 Suppose you have balanced a process and the amount or flow rate of one of the process streams is n1.
You can scale the flowchart to make the amount or flow rate of this stream n2 by multiplying all stream amounts or flow rates by the ratio n2/n1.

26 It is desired to achieve the same separation with a continuous feed of 1250 lb-moles/h. Scale the flowchart accordingly. The scale factor is:

27 Before scaling After scaling

28 General Procedure for Material Balance Calculations
Material balance on single unit process General Procedure for Material Balance Calculations Choose as a basis of calculations an amount or flow rate of one of the process streams Draw a flowchart of the process. Include all the given variables on the chart and label the unknown stream variables on the chart Write the expressions for the quantities requested in problem statement Convert all mass and molar unit quantities to one basis Do the degree of freedom analysis. For any given information that has not been used in labeling the flowchart, translate it into equations in terms of the unknown variables If nDF = 0, write material balance equations in an order such that those involve the fewest unknowns are written first Solve the equations and calculate the additional quantities requested in the problem statement Scale the quantities accordingly

29 Example :An aqueous solution of NaOH contains 20% NaOH by mass
Example :An aqueous solution of NaOH contains 20% NaOH by mass. It is desired to produce an 8% NaOH solution by diluting a stream of 20% solution with a stream of pure water. Calculate the ratios (liters H2O/kg feed solution) and (kg product solution/kg feed solution).

30 NaOH balance (input = output).
Total mass balance (input = output). Ratios requested in problem statement.