1 Oregon AHMA Bootcamp Friday “How to prepare your property for a REAC inspection!” February 29, 2008
2
2 Training Agenda FRIDAY, FEBRUARY 29 TH : 9:00 am – Welcome / Go over this thing 9:05 am – Scoring 10:00 am – “Top 20” 10:30 am – BREAK (15 Minutes) 10:45 am – “Top 20” (Continued) 12:00 pm – LUNCH (1 Hour) 1:00 pm – “Inspection Day” Video
3
3 Training Agenda (Continued) FRIDAY, FEBRUARY 29 TH : 2:00 pm – BREAK (15 Minutes) 2:15 pm – TR/DBAs, DCD 4.0, Website (Contiued) 3:00 pm – End for the Day 1:30 pm – TR/DBAs, DCD 4.0, Website
4
4 SCORING
5
5 The Goal Assign a score to the overall property condition based on the data collected by the inspector – Measure physical condition – Objective & consistent – Accommodates all property types & configurations
6
6 The inspector records the existence and the severity of deficiencies according to preset criteria Scoring is Based on Objective Data
7
7 Relative importance (“weights”) were assigned to each physical area, item, and deficiency in the inspection protocol HUD applies the weights to the inspection data to compute the score The score is based on a 100 point scale The Scoring Approach
8
8 The weights were assigned as part of a consensus process: - Industry stakeholder input Multifamily Housing (Owners / Agents) Public Housing Authorities Trade groups PHA industry groups - HUD information - Trade professionals’ experience Scoring Protocol
9
Site Building Exterior Common Areas Dwelling Units Fencing and Retaining Walls Grounds Lighting Mailboxes/Project Signs Market Appeal Parking Lots/Driveways/Roads Play Areas and Equipment Refuse Disposal Storm Drainage Walkways/Steps Doors Fire Escapes Foundations Lighting Roofs Walls Windows Domestic Water Electrical System Elevators Emergency Power Exhaust System Fire Protection HVAC Sanitary System Basement/Garage/Carport Office Closet/Utility/Mechanical Other Community Spaces Community Room Patio/Porch/Balcony Day Care Pools and Related Structures Halls/Corridors/Stairs Restrooms/Pool Structures Kitchen Storage Laundry Room Trash Collection Areas Lobby Bathroom Call-for-Aid Ceiling Doors Electrical System Floors Hot Water Heater HVAC System Kitchen Lighting Outlets/Switches Patio/Porch/Balcony Smoke Detector Stairs Walls Windows Building Systems Areas & Items 15% 20% 35%15%
10
10 Wgt15% 20%35%15%100% Property Physical Condition Inspection Areas Site Health & Safety Deductions Whole Point Deductions From Final Score Building Exterior Building Systems Dwelling Units Common Areas Building Scoring Dynamics
11
11 Wgt15% 20%35%15%100% Property Physical Condition Inspection Areas Site Health & Safety Deductions Whole Point Deductions From Final Score Building Exterior Building Systems Dwelling Units Common Areas Building Wgt15% 20%35%15%100% Wgt18% 23%41% 0%100% (For example, if there are no Common Areas on a property, the other inspection areas become more important) No Two Properties Are Alike
12
12 Scores calculated based on: Area Points x Item Weight x Criticality x Severity Ranges are: Area Points Site = 15Bldg Systems = 20Dwelling Units = 35 Bldg Ext = 15Common Areas = 15 Item Weight (Examples) Smoke Detector = 0Missing Toilet = 10 Damaged Ceiling = 4.5Misalinged Chimney = 15.5 Criticality (5) Critical = 5.0 (2) Contributes = 1.25 (4) Very Important = 3.0 (1) Slight Contribution = 0.5 (3) Important = 2.25 Severity (3) Most Severe = 1.0 (2) Severe = 0.50 (1) Least Severe = 0.25 Scoring Methodology
13
13 Dwelling Unit: Living Room, Ceiling - Holes/Missing... - Level 3 Scoring (Area Points x Item Weight x Criticality x Severity / # Units) 35 x 0.045 x 3.0 x 1.0 = 4.725 / 24 = 0.20 Point Deduction (Item Weight x Criticality x Severity) 4.5 x 3.0 x 1.0 = 13.5% *Assuming 250 Units (24 Sample Units)
14
14 Building Systems: Domestic Water, Misaligned Ventilation System - Level 3 Scoring *Assuming 5 Buildings * EH&S TICKET ITEM! * (Area Points Item Weight x Criticality x Severity / # Buildings) 20 x 0.155 x 5.0 x 1.0 = 15.5 / 5 = 3.10 Point Deduction (Item Weight x Criticality x Severity) 15.5 x 5.0 x 1.0 = 77.5%
15
15 Dwelling Units: Smoke Detector, Missing/Inoperable - Level 3 Scoring (Item Weight x Criticality x Severity) 0 x 5.0 x 1.0 = 0 no point deduction (Area Points x Item Weight x Criticality x Severity / # Units) 35 x 0 x 5.0 x 1.0 = 0 / 10 = no point deduction *Assuming 15 Units (10 Sample Units) * EH&S TICKET ITEM! *
16
16 “TOP 20”
17
17 DCD 2.3 INSPECTABLE DEFECTS
18
18 Before we begin … To fix anything you only need two things. - Duct Tape - WD-40
19
19 Before we begin … If it moves and it shouldn’t, use the duct tape. If it doesn’t and it should, use the WD-40.
20
20 Top 20 Deficiencies 1. HVAC – the water heater Pressure Relief Valve discharge tube extends to within 18 inches of the floor; 2. Misaligned Chimney – the vent stack on gas operated water heaters or furnaces are properly aligned; 3. Missing HVAC Covers – there are covers on all baseboard heaters; 4. Access to the Electrical Panel – access to electrical panels is not blocked by furniture or other items; 5. Missing Covers – electrical panels have interior covers (aside from the panel lid box itself) to prevent exposure from the wire connections; 6. Open Breaker Ports – Open breaker ports are covered; 7. Doors Damaged Seals – the factory-installed seals on Exterior Doors, such as building or unit doors, are in place and undamaged; Blah, blah, blah …
21
21 Top 20 Deficiencies 1. HVAC – the water heater Pressure Relief Valve discharge tube extends to within 18 inches of the floor; 2. Misaligned Chimney – the vent stack on gas operated water heaters or furnaces are properly aligned; 3. Missing HVAC Covers – there are covers on all baseboard heaters; 4. Access to the Electrical Panel – access to electrical panels is not blocked by furniture or other items; 5. Missing Covers – electrical panels have interior covers (aside from the panel lid box itself) to prevent exposure from the wire connections; 6. Open Breaker Ports – Open breaker ports are covered; 7. Doors Damaged Seals – the factory-installed seals on Exterior Doors, such as building or unit doors, are in place and undamaged; 8. Doors Damaged Hardware – Exterior door hardware locks or latches properly and Fire Doors function as designed; 9. Security Doors – security doors do not have dual-side key locks; 10. Kitchen – Damaged Stoves/Ovens – stove burners are working;
22
22 DEF:Missing Pressure Relief Valve (Domestic Water) - L3 BUILDING SYSTEMS
23
23 DEF:Missing Pressure Relief Valve (Domestic Water) - L3 BUILDING SYSTEMS
24
24 Top 20 Deficiencies 1. HVAC – the water heater Pressure Relief Valve discharge tube extends to within 18 inches of the floor; 2. Misaligned Chimney – the vent stack on gas operated water heaters or furnaces are properly aligned; 3. Missing HVAC Covers – there are covers on all baseboard heaters; 4. Access to the Electrical Panel – access to electrical panels is not blocked by furniture or other items; 5. Missing Covers – electrical panels have interior covers (aside from the panel lid box itself) to prevent exposure from the wire connections; 6. Open Breaker Ports – Open breaker ports are covered; 7. Doors Damaged Seals – the factory-installed seals on Exterior Doors, such as building or unit doors, are in place and undamaged; 8. Doors Damaged Hardware – Exterior door hardware locks or latches properly and Fire Doors function as designed; 9. Security Doors – security doors do not have dual-side key locks; 10. Kitchen – Damaged Stoves/Ovens – stove burners are working;
25
25 DEF: Misaligned Chimney/Ventilation Systems (Domestic Water) - L3 BUILDING SYSTEMS
26
26 Top 20 Deficiencies 1. HVAC – the water heater Pressure Relief Valve discharge tube extends to within 18 inches of the floor; 2. Misaligned Chimney – the vent stack on gas operated water heaters or furnaces are properly aligned; 3. Missing HVAC Covers – there are covers on all baseboard heaters; 4. Access to the Electrical Panel – access to electrical panels is not blocked by furniture or other items; 5. Missing Covers – electrical panels have interior covers (aside from the panel lid box itself) to prevent exposure from the wire connections; 6. Open Breaker Ports – Open breaker ports are covered; 7. Doors Damaged Seals – the factory-installed seals on Exterior Doors, such as building or unit doors, are in place and undamaged; 8. Doors Damaged Hardware – Exterior door hardware locks or latches properly and Fire Doors function as designed; 9. Security Doors – security doors do not have dual-side key locks; 10. Kitchen – Damaged Stoves/Ovens – stove burners are working;
27
27 UNIT DEF:Convection/Radiant Heat System Covers Missing/Damaged (HVAC) - L3 Health and Safety - Hazards/Sharp Edges Health and Safety - Other/Possible Burn Hazard
28
28 DEF:Convection/Radiant Heat System Covers Missing/Damaged (HVAC) - L3 Health and Safety - Hazards/Sharp Edges UNIT
29
29 Top 20 Deficiencies 1. HVAC – the water heater Pressure Relief Valve discharge tube extends to within 18 inches of the floor; 2. Misaligned Chimney – the vent stack on gas operated water heaters or furnaces are properly aligned; 3. Missing HVAC Covers – there are covers on all baseboard heaters; 4. Access to the Electrical Panel – access to electrical panels is not blocked by furniture or other items; 5. Missing Covers – electrical panels have interior covers (aside from the panel lid box itself) to prevent exposure from the wire connections; 6. Open Breaker Ports – Open breaker ports are covered; 7. Doors Damaged Seals – the factory-installed seals on Exterior Doors, such as building or unit doors, are in place and undamaged; 8. Doors Damaged Hardware – Exterior door hardware locks or latches properly and Fire Doors function as designed; 9. Security Doors – security doors do not have dual-side key locks; 10. Kitchen – Damaged Stoves/Ovens – stove burners are working;
30
30 Top 20 Deficiencies 1. HVAC – the water heater Pressure Relief Valve discharge tube extends to within 18 inches of the floor; 2. Misaligned Chimney – the vent stack on gas operated water heaters or furnaces are properly aligned; 3. Missing HVAC Covers – there are covers on all baseboard heaters; 4. Access to the Electrical Panel – access to electrical panels is not blocked by furniture or other items; 5. Missing Covers – electrical panels have interior covers (aside from the panel lid box itself) to prevent exposure from the wire connections; 6. Open Breaker Ports – Open breaker ports are covered; 7. Doors Damaged Seals – the factory-installed seals on Exterior Doors, such as building or unit doors, are in place and undamaged; 8. Doors Damaged Hardware – Exterior door hardware locks or latches properly and Fire Doors function as designed; 9. Security Doors – security doors do not have dual-side key locks; 10. Kitchen – Damaged Stoves/Ovens – stove burners are working;
31
31 DEF:Missing Breakers (Electrical System) - L3 DEF:Missing Covers (Electrical System) - L3 BUILDING SYSTEMS
32
32 DEF:Missing Covers (Electrical System) - L3 BUILDING SYSTEMS
33
33 Top 20 Deficiencies 1. HVAC – the water heater Pressure Relief Valve discharge tube extends to within 18 inches of the floor; 2. Misaligned Chimney – the vent stack on gas operated water heaters or furnaces are properly aligned; 3. Missing HVAC Covers – there are covers on all baseboard heaters; 4. Access to the Electrical Panel – access to electrical panels is not blocked by furniture or other items; 5. Missing Covers – electrical panels have interior covers (aside from the panel lid box itself) to prevent exposure from the wire connections; 6. Open Breaker Ports – Open breaker ports are covered; 7. Doors Damaged Seals – the factory-installed seals on Exterior Doors, such as building or unit doors, are in place and undamaged; 8. Doors Damaged Hardware – Exterior door hardware locks or latches properly and Fire Doors function as designed; 9. Security Doors – security doors do not have dual-side key locks; 10. Kitchen – Damaged Stoves/Ovens – stove burners are working;
34
34 Top 20 Deficiencies 1. HVAC – the water heater Pressure Relief Valve discharge tube extends to within 18 inches of the floor; 2. Misaligned Chimney – the vent stack on gas operated water heaters or furnaces are properly aligned; 3. Missing HVAC Covers – there are covers on all baseboard heaters; 4. Access to the Electrical Panel – access to electrical panels is not blocked by furniture or other items; 5. Missing Covers – electrical panels have interior covers (aside from the panel lid box itself) to prevent exposure from the wire connections; 6. Open Breaker Ports – Open breaker ports are covered; 7. Doors Damaged Seals – the factory-installed seals on Exterior Doors, such as building or unit doors, are in place and undamaged; 8. Doors Damaged Hardware – Exterior door hardware locks or latches properly and Fire Doors function as designed; 9. Security Doors – security doors do not have dual-side key locks; 10. Kitchen – Damaged Stoves/Ovens – stove burners are working;
35
35 DEF:Damaged Hardware/Locks (Doors) - L3 Damaged Surface - Holes/Paint/Rusting/Glass (Doors) - L3 Health and Safety - Blocked Egress UNIT
36
36 UNIT DEF:Damaged Hardware/Locks (Doors) - L2 Damaged Surface - Holes/Paint/Rusting/Glass (Doors) - L2
37
37 Top 20 Deficiencies 1. HVAC – the water heater Pressure Relief Valve discharge tube extends to within 18 inches of the floor; 2. Misaligned Chimney – the vent stack on gas operated water heaters or furnaces are properly aligned; 3. Missing HVAC Covers – there are covers on all baseboard heaters; 4. Access to the Electrical Panel – access to electrical panels is not blocked by furniture or other items; 5. Missing Covers – electrical panels have interior covers (aside from the panel lid box itself) to prevent exposure from the wire connections; 6. Open Breaker Ports – Open breaker ports are covered; 7. Doors Damaged Seals – the factory-installed seals on Exterior Doors, such as building or unit doors, are in place and undamaged; 8. Doors Damaged Hardware – Exterior door hardware locks or latches properly and Fire Doors function as designed; 9. Security Doors – security doors do not have dual-side key locks; 10. Kitchen – Damaged Stoves/Ovens – stove burners are working;
38
38 Top 20 Deficiencies 1. HVAC – the water heater Pressure Relief Valve discharge tube extends to within 18 inches of the floor; 2. Misaligned Chimney – the vent stack on gas operated water heaters or furnaces are properly aligned; 3. Missing HVAC Covers – there are covers on all baseboard heaters; 4. Access to the Electrical Panel – access to electrical panels is not blocked by furniture or other items; 5. Missing Covers – electrical panels have interior covers (aside from the panel lid box itself) to prevent exposure from the wire connections; 6. Open Breaker Ports – Open breaker ports are covered; 7. Doors Damaged Seals – the factory-installed seals on Exterior Doors, such as building or unit doors, are in place and undamaged; 8. Doors Damaged Hardware – Exterior door hardware locks or latches properly and Fire Doors function as designed; 9. Security Doors – security doors do not have dual-side key locks; 10. Kitchen – Damaged Stoves/Ovens – stove burners are working;
39
39 UNIT DEF:Range/Stove - Missing/Damaged/Inoperable (Kitchen) - L2
40
40 Top 20 Deficiencies (Continued) 11. Plumbing – pipes and faucets are not leaking, and areas around any leaks are cleaned up and repaired; 12. Damaged Sinks/Showers – any hardware problems are repaired, diverters are working, drains have stoppers, Hot or Cold water handles are in place and working; 13. Clothes Dryers - are properly vented to the outside from units or laundry rooms; 14. Storm Water Sewers - are not clogged with trash or leaves; 15. Sanitary Sewer Damaged Covers –caps located in the grass on the exterior of the building that have been damaged by a lawn mower are cleaned out. Replace and mark the areas to prevent further damage; 16. Trash Chutes – hardware is in place and the chute door closes properly; 17. Trash Receptacles - are not overflowing and are adequate in size for the property; 18. Auxiliary Lighting – the back up lighting works even when the test light does not work; 19. Leaking Domestic Water – there are no leaks in the domestic water supply, including the hose bibs located on the exterior of the building; 20. Switchplate Covers – are not cracked or broken.
41
41 UNIT DEF:Plumbing - Leaking Faucets/Pipes (Kitchen) - L3
42
42 Top 20 Deficiencies (Continued) 11. Plumbing – pipes and faucets are not leaking, and areas around any leaks are cleaned up and repaired; 12. Damaged Sinks/Showers – any hardware problems are repaired, diverters are working, drains have stoppers, Hot or Cold water handles are in place and working; 13. Clothes Dryers - are properly vented to the outside from units or laundry rooms; 14. Storm Water Sewers - are not clogged with trash or leaves; 15. Sanitary Sewer Damaged Covers –caps located in the grass on the exterior of the building that have been damaged by a lawn mower are cleaned out. Replace and mark the areas to prevent further damage; 16. Trash Chutes – hardware is in place and the chute door closes properly; 17. Trash Receptacles - are not overflowing and are adequate in size for the property; 18. Auxiliary Lighting – the back up lighting works even when the test light does not work; 19. Leaking Domestic Water – there are no leaks in the domestic water supply, including the hose bibs located on the exterior of the building; 20. Switchplate Covers – are not cracked or broken.
43
43 DEF:Lavatory Sink - Damaged/Missing (Bathroom) - L3 Bathroom Cabinets - Damaged/Missing (Bathroom) - L1 UNIT
44
44 UNIT DEF:Water Closet/Toilet - Damaged/Clogged/Missing (Bathroom) – L2
45
45 UNIT DEF: Lavatory Sink - Damaged/Missing (Bathroom) - L3 Water Closet/Toilet - Damaged/Clogged/Missing (Bathroom) - L3
46
46 Top 20 Deficiencies (Continued) 11. Plumbing – pipes and faucets are not leaking, and areas around any leaks are cleaned up and repaired; 12. Damaged Sinks/Showers – any hardware problems are repaired, diverters are working, drains have stoppers, Hot or Cold water handles are in place and working; 13. Clothes Dryers - are properly vented to the outside from units or laundry rooms; 14. Storm Water Sewers - are not clogged with trash or leaves; 15. Sanitary Sewer Damaged Covers –caps located in the grass on the exterior of the building that have been damaged by a lawn mower are cleaned out. Replace and mark the areas to prevent further damage; 16. Trash Chutes – hardware is in place and the chute door closes properly; 17. Trash Receptacles - are not overflowing and are adequate in size for the property; 18. Auxiliary Lighting – the back up lighting works even when the test light does not work; 19. Leaking Domestic Water – there are no leaks in the domestic water supply, including the hose bibs located on the exterior of the building; 20. Switchplate Covers – are not cracked or broken.
47
47 Top 20 Deficiencies (Continued) 11. Plumbing – pipes and faucets are not leaking, and areas around any leaks are cleaned up and repaired; 12. Damaged Sinks/Showers – any hardware problems are repaired, diverters are working, drains have stoppers, Hot or Cold water handles are in place and working; 13. Clothes Dryers - are properly vented to the outside from units or laundry rooms; 14. Storm Water Sewers - are not clogged with trash or leaves; 15. Sanitary Sewer Damaged Covers –caps located in the grass on the exterior of the building that have been damaged by a lawn mower are cleaned out. Replace and mark the areas to prevent further damage; 16. Trash Chutes – hardware is in place and the chute door closes properly; 17. Trash Receptacles - are not overflowing and are adequate in size for the property; 18. Auxiliary Lighting – the back up lighting works even when the test light does not work; 19. Leaking Domestic Water – there are no leaks in the domestic water supply, including the hose bibs located on the exterior of the building; 20. Switchplate Covers – are not cracked or broken.
48
48 Top 20 Deficiencies (Continued) 11. Plumbing – pipes and faucets are not leaking, and areas around any leaks are cleaned up and repaired; 12. Damaged Sinks/Showers – any hardware problems are repaired, diverters are working, drains have stoppers, Hot or Cold water handles are in place and working; 13. Clothes Dryers - are properly vented to the outside from units or laundry rooms; 14. Storm Water Sewers - are not clogged with trash or leaves; 15. Sanitary Sewer Damaged Covers –caps located in the grass on the exterior of the building that have been damaged by a lawn mower are cleaned out. Replace and mark the areas to prevent further damage; 16. Trash Chutes – hardware is in place and the chute door closes properly; 17. Trash Receptacles - are not overflowing and are adequate in size for the property; 18. Auxiliary Lighting – the back up lighting works even when the test light does not work; 19. Leaking Domestic Water – there are no leaks in the domestic water supply, including the hose bibs located on the exterior of the building; 20. Switchplate Covers – are not cracked or broken.
49
49 DEF:Missing Drain/Cleanout/Manhole Covers (Sanitary System) - L3 BUILDING SYSTEMS
50
50 DEF:Missing Drain/Cleanout/Manhole Covers (Sanitary System) - L3 BUILDING SYSTEMS
51
51 Top 20 Deficiencies (Continued) 11. Plumbing – pipes and faucets are not leaking, and areas around any leaks are cleaned up and repaired; 12. Damaged Sinks/Showers – any hardware problems are repaired, diverters are working, drains have stoppers, Hot or Cold water handles are in place and working; 13. Clothes Dryers - are properly vented to the outside from units or laundry rooms; 14. Storm Water Sewers - are not clogged with trash or leaves; 15. Sanitary Sewer Damaged Covers –caps located in the grass on the exterior of the building that have been damaged by a lawn mower are cleaned out. Replace and mark the areas to prevent further damage; 16. Trash Chutes – hardware is in place and the chute door closes properly; 17. Trash Receptacles - are not overflowing and are adequate in size for the property; 18. Auxiliary Lighting – the back up lighting works even when the test light does not work; 19. Leaking Domestic Water – there are no leaks in the domestic water supply, including the hose bibs located on the exterior of the building; 20. Switchplate Covers – are not cracked or broken.
52
52 DEF:Chutes Damaged/Missing Components - L3 COMMON AREAS
53
53 Top 20 Deficiencies (Continued) 11. Plumbing – pipes and faucets are not leaking, and areas around any leaks are cleaned up and repaired; 12. Damaged Sinks/Showers – any hardware problems are repaired, diverters are working, drains have stoppers, Hot or Cold water handles are in place and working; 13. Clothes Dryers - are properly vented to the outside from units or laundry rooms; 14. Storm Water Sewers - are not clogged with trash or leaves; 15. Sanitary Sewer Damaged Covers –caps located in the grass on the exterior of the building that have been damaged by a lawn mower are cleaned out. Replace and mark the areas to prevent further damage; 16. Trash Chutes – hardware is in place and the chute door closes properly; 17. Trash Receptacles - are not overflowing and are adequate in size for the property; 18. Auxiliary Lighting – the back up lighting works even when the test light does not work; 19. Leaking Domestic Water – there are no leaks in the domestic water supply, including the hose bibs located on the exterior of the building; 20. Switchplate Covers – are not cracked or broken.
54
54 DEF:Site - Garbage and Debris - Outdoors HEALTH & SAFETY
55
55 Top 20 Deficiencies (Continued) 11. Plumbing – pipes and faucets are not leaking, and areas around any leaks are cleaned up and repaired; 12. Damaged Sinks/Showers – any hardware problems are repaired, diverters are working, drains have stoppers, Hot or Cold water handles are in place and working; 13. Clothes Dryers - are properly vented to the outside from units or laundry rooms; 14. Storm Water Sewers - are not clogged with trash or leaves; 15. Sanitary Sewer Damaged Covers –caps located in the grass on the exterior of the building that have been damaged by a lawn mower are cleaned out. Replace and mark the areas to prevent further damage; 16. Trash Chutes – hardware is in place and the chute door closes properly; 17. Trash Receptacles - are not overflowing and are adequate in size for the property; 18. Auxiliary Lighting – the back up lighting works even when the test light does not work; 19. Leaking Domestic Water – there are no leaks in the domestic water supply, including the hose bibs located on the exterior of the building; 20. Switchplate Covers – are not cracked or broken.
56
56 DEF:Auxiliary Lighting Inoperable (Emergency Power) - L3 BUILDING SYSTEMS
57
57 Top 20 Deficiencies (Continued) 11. Plumbing – pipes and faucets are not leaking, and areas around any leaks are cleaned up and repaired; 12. Damaged Sinks/Showers – any hardware problems are repaired, diverters are working, drains have stoppers, Hot or Cold water handles are in place and working; 13. Clothes Dryers - are properly vented to the outside from units or laundry rooms; 14. Storm Water Sewers - are not clogged with trash or leaves; 15. Sanitary Sewer Damaged Covers –caps located in the grass on the exterior of the building that have been damaged by a lawn mower are cleaned out. Replace and mark the areas to prevent further damage; 16. Trash Chutes – hardware is in place and the chute door closes properly; 17. Trash Receptacles - are not overflowing and are adequate in size for the property; 18. Auxiliary Lighting – the back up lighting works even when the test light does not work; 19. Leaking Domestic Water – there are no leaks in the domestic water supply, including the hose bibs located on the exterior of the building; 20. Switchplate Covers – are not cracked or broken.
58
58 DEF:Leaking Central Water Supply (Domestic Water) - L3 BUILDING SYSTEMS
59
59 DEF:Leaking Central Water Supply (Domestic Water) - L3 BUILDING SYSTEMS
60
60 Top 20 Deficiencies (Continued) 11. Plumbing – pipes and faucets are not leaking, and areas around any leaks are cleaned up and repaired; 12. Damaged Sinks/Showers – any hardware problems are repaired, diverters are working, drains have stoppers, Hot or Cold water handles are in place and working; 13. Clothes Dryers - are properly vented to the outside from units or laundry rooms; 14. Storm Water Sewers - are not clogged with trash or leaves; 15. Sanitary Sewer Damaged Covers –caps located in the grass on the exterior of the building that have been damaged by a lawn mower are cleaned out. Replace and mark the areas to prevent further damage; 16. Trash Chutes – hardware is in place and the chute door closes properly; 17. Trash Receptacles - are not overflowing and are adequate in size for the property; 18. Auxiliary Lighting – the back up lighting works even when the test light does not work; 19. Leaking Domestic Water – there are no leaks in the domestic water supply, including the hose bibs located on the exterior of the building; 20. Switchplate Covers – are not cracked or broken.
61
61 UNIT DEF:Missing/Broken Cover Plates (Outlets/Switches) - L3
62
62 TR/DBAs
63
63 Technical Reviews What qualifies for a Technical Review? - Building Data Errors - Unit Count Errors - Non-Existent Deficiency Errors You can appeal a physical score if you believe the inspection was not conducted in accordance with the Public and Indian Housing Real Estate Assessment Center (PIH-REAC) Uniform Physical Condition Standards (UPCS) inspection protocol or feel that certain inspection data may have been recorded in error that, if corrected, will result in an improvement in the property's overall score What does NOT qualify for a Technical Review? - Disagreements over the severity of a defect - Deficiencies that were repaired or corrected
64
64 Technical Reviews (Continued) Timeline for submittal: - Public Housing = 15 days - Multifamily Housing = 30 days What to include: - All property identification information - All deficiency location information How to document: - Written Material - Photographs - Video * OBJECTIVELY VERIFIABLE! *
65
65 Technical Reviews (Continued) Where to send your request: Attn: PASS Technical Reviews HUD/PIH/REAC 550 12 th Street SW, Suite 100 Washington, DC 20410 What can happen: - Request Denied - New Inspection Scheduled - Correct the Inspection Report (Adjust score)
66
66 What qualifies for a Database Adjustment? - Local conditions and exceptions - Ownership issues - Adverse conditions beyond the owner’s control - Modernization work in progress You can appeal a physical score if you believe the inspection was not conducted in accordance with … blah … blah … blah … (Same as the previous one.) What does NOT qualify for a Database Adjustment? - Deficiencies that were repaired or corrected - Deficiencies caused by residents - Items covered by the Technical Review process Database Adjustments
67
67 Timeline for submittal: - Public Housing = 15 days - Multifamily Housing = 45 days What to include: - All property identification information - All deficiency location information How to document: - Written Material - Photographs - Video * OBJECTIVELY VERIFIABLE! * Database Adjustments (Continued)
68
68 Where to send your request: Attn: PASS Database Adjustments HUD/PIH/REAC 550 12 th Street SW, Suite 100 Washington, DC 20410 What can happen: - Request Denied - New Inspection Scheduled - Correct the Inspection Report (Adjust score) Database Adjustments (Continued)
69
69 DCD 4.0
70
70 Why DCD 4.0? –Increased system reliability –Upgraded technology –Implementation of Berger 47 Deficiency Definitions through Decision Trees Improved consistency between inspectors Eliminates interpretation of inspector comments Logical, universally defined progression to determine and document results –Decreased processing times When can we expect to see DCD 4.0? –Fall 2008 –Full implementation in 2009 DCD 4.0 (A.K.A. RAPID 1.0)
71
71 DCD 4.0 (A.K.A. RAPID 1.0 - Continued)
72
72 DCD 4.0 (A.K.A. RAPID 1.0 - Continued)
73
73 WEBSITE
74
74 http://www.hud.gov/offices/reac/ products/pass/pass_trng.cfm