Download presentation
Presentation is loading. Please wait.
Published byHortense Nicholson Modified over 8 years ago
1
Unity Application Generator Step 7b: Generating HMI
2
Schneider Electric 2 - EU – UAG team, Feb 2010 Steps ●After performing step mentioned in document “7a- Generate PLC.ppt”, Click on GENERATE HMI ●This window will appear: ●Note: UAG will be opening VJC, generating the project along with screens and Genies. ●IMPORTANT: Please wait till generation is completed.
3
Schneider Electric 3 - EU – UAG team, Feb 2010 Steps ●After success full completion, this message will appear: ●Check there must be no errors. Having warnings should not be an issue.
4
Schneider Electric 4 - EU – UAG team, Feb 2010 Steps ●Open Vijeo Citect project by click Vijeo Citect icon: this window will be appeared. Click on “Vijeo Citect” icon to open the project
5
Schneider Electric 5 - EU – UAG team, Feb 2010 Steps ●Vijeo Citect will be opened with the project “MyHMI”.
6
Schneider Electric 6 - EU – UAG team, Feb 2010 Steps ●Expand “MyHMI” and click on Graphics /Pages and open picture “MyPicGroup_MyPic”:
7
Schneider Electric 7 - EU – UAG team, Feb 2010 Steps ●The screen “MyPic” will look like this: note the UAG has generated the genies. ●Arrange the Genies at proper positions in the screen and save.
8
Schneider Electric 8 - EU – UAG team, Feb 2010 Steps Defining a user ●Open Vijeo Citect project editor: ●Define a user by clicking on SYSTEM USER:
9
Schneider Electric 9 - EU – UAG team, Feb 2010 Steps ●This window will be appeared: ●Key-in user name, password (I have used “ad” as password. Important is write enough rights by keying-in “Manager” in TYPE field and 1..8 in Global privilege: ●This screen should like this and then click on “add” button.
10
Schneider Electric 10 - EU – UAG team, Feb 2010 Steps: Pack and compile ●Click on File Pack. ●After Pack operation completed, compile the project by clicking on FILE Compile
11
Schneider Electric 11 - EU – UAG team, Feb 2010 Steps: Pack and compile ●This window will appear: ●There should be no error after compile. ●IMPORTANT: If you are running your demo project for the first time, then please make computer setup by clicking on TOOLS Computer Setup Wizard ●Details screen shorts are given in slide 19 and onwards.
12
Schneider Electric 12 - EU – UAG team, Feb 2010 Steps: Running the VJC project ●Now you are ready to RUN the Viejo Citect project. ●Click on FILE RUN. ●This window will be appeared: after the RUNTIME MANAGER starts all the process, main screen of Vijeo Citect will be appeared:
13
Schneider Electric 13 - EU – UAG team, Feb 2010 Steps: Running the VJC project ●Main VJC screen: ●Log on with user “ad” and password. ●Click on MyPicGroup and then on MYPic. Click on “Log On” icon for logging on
14
Schneider Electric 14 - EU – UAG team, Feb 2010 Steps: Running the VJC project ●This screen will appear: ●Note that the name of the user is “ad”. ●Note that genies of all the Control modules are present. User is “ad”
15
Schneider Electric 15 - EU – UAG team, Feb 2010 Steps: Running the VJC project ●Click on Equip1_OPM1, this pop will appear: ●Click on HMI in the pop up and see the command is sent to corresponding section in Unity Pro. ●Also check the status of the EQUIP1_OPM1: it must have been changed to HMI, like this: HMI selected
16
Schneider Electric 16 - EU – UAG team, Feb 2010 Steps: Running the VJC project ●After selecting clicking on HMI, click on MAN icon. ●Click on HMI in the pop up and see the command is sent to corresponding section in Unity Pro. ●Also check the status of the EQUIP1_OPM1: it must have been changed like this: Manual mode
17
Schneider Electric 17 - EU – UAG team, Feb 2010 Steps: Running the VJC project ●Continue with the EQUIP1_Mot1. ●Click on MAN; AUTO, START AND STOP function and check outputs in the corresponding section in Unity Pro. ●Also check the status of the EQUIP1_Mot1 Manual /Auto mode START /STOP
18
Schneider Electric 18 - EU – UAG team, Feb 2010 Steps: Running the VJC project ●Suggestions: Explore communications, variables, alarms, screens and genies in VJC and demonstrate that all these aspects are generated automatically by UAG.
19
Schneider Electric 19 - EU – UAG team, Feb 2010 Steps: Computer set up wizard ●IMPORTANT: Required only if you are running a VJC project for the first time. ●Click on TOOLS Computer Setup Wizard in Citect Project editor. ●This window will appear: ●Keep on moving to next step after ensuring the parameters are set as given in these screen shots.
20
Schneider Electric 20 - EU – UAG team, Feb 2010 Steps: Computer set up wizard Click on next to get this screen
21
Schneider Electric 21 - EU – UAG team, Feb 2010 Steps: Computer set up wizard Click on next to get this screen
22
Schneider Electric 22 - EU – UAG team, Feb 2010 Steps: Computer set up wizard Click on next to get this screen
23
Schneider Electric 23 - EU – UAG team, Feb 2010 Steps: Computer set up wizard Click on next to get this screen Click and modify by using MODIFY button
24
Schneider Electric 24 - EU – UAG team, Feb 2010 Steps: Computer set up wizard Click on next to get this screen Click and modify by using MODIFY button: Startup() is the right value.
25
Schneider Electric 25 - EU – UAG team, Feb 2010 Steps: Computer set up wizard Click on next to get this screen
26
Schneider Electric 26 - EU – UAG team, Feb 2010 Steps: Computer set up wizard Click on next to get this screen
27
Schneider Electric 27 - EU – UAG team, Feb 2010 Steps: Computer set up wizard Click on next to get this screen Click on Finish and go back to activity given in slide 11
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.