1 IEEE 11073 GC Montreal 2016-05-10 IEEE 11073 Nomenclature IEEE 11073 GC at HL7, Montreal, Quebec Tuesday Q2 – May 10, 2016 Paul Schluter, GE Healthcare
2
2 IEEE 11073 GC Montreal 2016-05-10 Topics IEEE Std 11073-10101 and NIST RTMMS Update IEEE P11073-10101b – new terminology (PAR approved) IEEE P11073-10101c – events and alerts (PAR pending) IEEE P11073-10103a – IDC extensions (PAR approved) NIST RTMMS – accelerate numeric code assignments PHD Terminology in NIST RTMMS (with Malcolm Clarke)
3
3 IEEE 11073 GC Montreal 2016-05-10 IEEE Std 11073-10101a and NIST RTMMS update Approved by IEEE-SA Standards Board on December 5, 2015 Published on December 9 th and uploaded to NIST RTMMS NIST RTMMS has been updated with -10101a nomenclature and was used for limited testing at IHE NA Connectathon. Co-constraints (units, enums and sites) for new -10101a terms have been uploaded to NIST RTMMS will be available shortly, pending final review and verification. The new second-generation harmonized Rosetta, hRTM2, will combine the ‘old’ 10101 and ‘new’ 10101a terms and co-constraints, and use -10102 aECG lead offsets 65. XSL Output.x2c.2016-02-09T13.html (hRTM2 html) XSL Output.x1e.2016-05-06T11.uom.html (UOM comparison with NIST RTMMS) XSL Output.x2c.2016-02-09T13.html XSL Output.x1e.2016-05-06T11.uom.html Co-constraints for several PHD devices will also be included, based on published -20601 PHD and -104xx specializations.
4
4 IEEE 11073 GC Montreal 2016-05-10 IEEE P11073-10101b [PAR approved] Extends ISO/IEEE Std 11073-10101:2004 and -10101a-2015: Infusion pumps and infusion events (IHE PCD PIV and IPEC) Ventilator mode, high-frequency ventilation, annotations NMT Neuromuscular transmission (level of neuromuscular block) NMT.ParameterList.4a.2016-04-13T12.docx (use ‘named’ data items; enumerated values next) NMT.ParameterList.4a.2016-04-13T12.docx Finalize the WCM waveform attributes (or just use aECG) IHE PCD Device Management Control (DMC) IHE PCD Real-Time Location Services (LS) Generalized Signal Quality Index Dialysis Surgical and OR devices (by OR.NET at http://www.ornet.org/) Additional observation identifiers and settings Note: Inclusion of content in draft standard is contingent on timely completion.
5
5 IEEE 11073 GC Montreal 2016-05-10 IEEE P11073-10101c [PAR to be approved] Existing list of ISO/IEEE 11073-10101:2004 MDC_EVT_ identifiers will be extended to support the IHE PCD Rosetta for Events and Alerts. Will cover physiologic alerts and essential technical events and alerts PAR: IEEE P11073-10101c- PAR Detail_jw1.pdfIEEE P11073-10101c- PAR Detail_jw1.pdf Action required: IEEE 11073 leadership approval to move forward.
6
6 IEEE 11073 GC Montreal 2016-05-10 IEEE P11073-10103a [PAR approved] Extends IEEE P11073-10103:2012 Implanted Devices Cardiac New IDC term codes, extending IEEE P11073-10103:2012 Considering EGM waveforms. New terms were presented and discussed at the Heart Rhythm Society (HRS) meeting in San Francisco last weekend. See presentation: IDC_nomenclature_status_May2016_v03.pdfIDC_nomenclature_status_May2016_v03.pdf
7
7 IEEE 11073 GC Montreal 2016-05-10 New Term REFID and Code Assignments Background for this discussion, motivated by the desirability of having numeric code assignments at the earliest possible time. Use NIST RTMMS as the authoritative numeric code generator for new terms to guarantee non-overlap between multiple organizations, e.g. IEEE 11073, IHE PCD DEC, PCHA. If the proposed Reference ID, Disc, Part::Code is discarded during balloting, it is retired as a “zombie term” and cannot be re-used. Is this a good idea? Yes, if we can keep the number of “zombie terms” to a small number (< 5 – 10% of new terms defined). No, we could end up with a ‘free-for-all’ if this is uncontrolled without any degree of editorial review and curation.