Download presentation
Published byDaniella Evans Modified over 8 years ago
1
RAMAN SPECTROSCOPY SUBMITTED BY: FARHEENA KHURSHID
2
Raman Spectroscopy Raman effect is a 2-photon scattering process
These processes are inelastic scattering: Stokes scattering: energy lost by photon: — (( — )) Photon in Photon out No vibration Vibration Anti-Stokes scattering: energy gained by photon: (( — )) — Vibration No vibration
3
But dominant process is elastic scattering:
Rayleigh scattering — — Photon in Photon out No vibration No vibration If incident photon energy E; vibration energy v, then in terms of energy, photon out has energy: E-v Stokes scattering E+v anti-Stokes scattering E Rayleigh scattering
4
Representation in terms of energy levels:
Arrow up = laser photon in; Arrow down = Raman scattering out
5
Typical Raman spectrum Plot of signal intensity vs Raman shift
(Raman shift, in cm-1 = energy of photon in-energy of photon out) shows 3 vibrations of octahedral BiCl63-
6
Selection rule for Raman spectrum
Vibration is active if it has a change in polarizability, . Polarizability is the ease of distortion of a bond. For Raman-active vibrations, the incident radiation does not cause a change in the dipole moment of the molecule, but instead a change in polarizability. In starting the vibration going, the electric field of the radiation at time t, E, induces a separation of charge (i.e. between the nuclear protons and the bonding electrons). This is called the induced dipole moment, P. (Don’t confuse it with the molecule’s dipole moment, or change in dipole moment, because this is often zero). P = E
7
Example: There are 4 normal modes of CO2. Only 1 is Raman active
is dipole moment; is polarizability; Q is vibration coordinate, The slopes are measured at Q = 0 (I.e. at the equilibrium position). Change in dipole moment, , and polarizability, , during CO2 vibrations 3
8
Uses of Raman Spectroscopy
Raman spectroscopy has become more widely used since the advent of FT-Raman systems and remote optical fibre sampling. Previous difficulties with laser safety, stability and precision have largely been overcome. Basically, Raman spectroscopy is complementary to IR spectroscopy, but the sampling is more convenient, since glass containers may be used and solids do not have to be mulled or pressed into discs.
9
Applications of Raman spectroscopy
Qualitative tool for identifying molecules from their vibrations, especially in conjunction with infrared spectrometry. Quantitative Raman measurements a) not sensitive since Raman scattering is weak. But resonance Raman spectra offer higher sensitivity, e.g. fabric dyes studied at ppb. b) beset by difficulties in measuring relative intensities of bands from different samples, due to sample alignment, collection efficiency, laser power. Overcome by using internal standard.
10
Raman and fluorescence spectra
The diagram shows some of the energy levels of the uranyl ion. UO22+ 20000 cm-1 Energy ___________ cm-1 ___________ cm-1 The vibrational level at 800 cm-1 is the totally symmetric stretch. The electronic levels are fairly continuous above cm-1. What happens if you excite with a laser at (a) cm-1? (b) cm-1? (c) cm-1?
11
Raman vs IR spectroscopy
RAMAN IR Sample preparation usually simpler Liquid/ Solid samples must be free from dust Biological materials usually fluoresce, masking scattering Spectral measurements on vibrations Halide optics must be used- made in the visible region-glass cells expensive, easily broken, may be used water soluble Depolarization studies are easily made IR spectrometers not usually (laser radiation almost totally linearly equipped with polarizers polarized)
12
More about polarizability
, polarizability of molecule, related to mobility of electrons (under applied radiation field in our present case). For atoms, same distortion is obtained for field in any direction. Polarizability is Isotropic For many molecules, polarizability depends on direction of applied field, e.g. H—H easier to distort along bond than bond. Polarizability is anisotropic Variation of with direction is described by polarizability tensor.
14
Calculation of Stokes and anti-Stokes intensity ratio
The Raman spectrum was taken at 300 K using 1064 nm Nd-YAG radiation. Check the intensity ratio of the 1 features at 278.5 cm-1. What can you say about the intensity ratio of the band at 112 cm-1?
15
Instrumentation Dispersive Raman instruments Laser Sample Double or triple monochromator signal processing and output Photomultiplier tube The monochromators are required to separate the weak Raman signal from the intense, nearby Rayleigh scattering. Typical lasers are Ar+ (e.g. green line, nm) or Kr+ (e.g. yellow line, nm).
16
Fourier transform Raman spectrometer
The Raman instrument can be on the same bench as the FTIR. Often, a YAG:Nd3+ laser (1064 nm) is used to excite the sample, so that the excitation energy is lower than the absorption band energies of organic systems. Fluorescence is then minimized. Instruments may be combined with a microscope, or optical fibre, so that scanning over a few (microns)2 of surface area, and Raman mapping is easily performed.
17
Sampling techniques for Raman spectroscopy
If the sample is colourless, it does not absorb a visible laser Raman spectroscopy is applicable to solids, liquids or gases. Gases: use gas cell
18
Liquids and solids can be
sealed in a glass capillary: If the compound is colored, it can absorb the laser, get hot and decompose. Some techniques are: • Reduce the laser power (defocus) and/or change wavelength; • Dilute the sample into a KBr pellet; • Cool the sample • Rotate or oscillate the laser beam on the sample
19
Number of bands in a Raman spectrum
As for an IR spectrum, the number of bands in the Raman spectrum for an N-atom non-linear molecule is seldom 3N-6, because: polarizability change is zero or small for some vibrations; bands overlap; combination or overtone bands are present; Fermi resonances occur; some vibrations are highly degenerate; etc…
20
High resolution Raman spectra can show splittings due to isotopic mass effects, for example: the 1 Raman band of CCl4 (corresponding tp the totally symmetric stretching vibration) is split into 5 components. 461.5 cm-1 is due to 35Cl4C 458.4 cm-1 is due to 35Cl337ClC 455.1 cm-1 is due to 35Cl237Cl2C What are the two question marks? Why are these bands weak?
21
Depolarization ratio of a vibrational mode in the Raman spectrum
may give information about the symmetry of a vibration. p = depolarization ratio for polarized light = Iy/Iz = I/I|| This is different from the depolarization ratio for unpolarized light, see Infrared and Raman Spectra…Part A., K. Nakamoto 5th Ed. Wiley Pp 0 p <0.75; Raman line is polarized (p). Vibration is totally symmetric p = Raman line is depolarized (dp). Vibration is not totally symmetric. CCl4
22
Special types of Raman spectroscopy
(see Hollas, Modern Spectroscopy, Wiley) Resonance Raman (RR) scattering When the laser excitation frequency is near (or coincident) with an electronic absorption band, intensity enhancement can occur by a factor of , compared with normal Raman scattering. Electronic transitions are often localized in one part of a molecule, so that RR provides information about vibrations of the chromophore, especially those exhibiting a large change in geometry between the two electronic states. RR is used in analytical chemistry to achieve detection limits M. Surface enhanced Raman spectroscopy (SERS): Raman scattering is enhanced (typically by times) when the analyte is adsorbed on colloidal metallic surfaces, e.g. on colloidal Ag prepared by reduction of Ag+ with citrate, in particle size range nm.
23
Stimulated Raman scattering (SRS)
The Raman scattering from a laser is observed in the forward direction from the sample (i.e. in the same direction, or at a small angle to the incident laser radiation). Vibrational progressions are observed for certain modes. Coherent anti-Stokes Raman spectroscopy (CARS) Radiation from two lasers is incident on the sample, and the intensity of the outgoing wave energy gives information about the vibrational modes of the sample. Hyper-Raman spectroscopy Very weak scattering at twice the laser frequency, 20, is called Hyper-Rayleigh scattering. Similarly, Stokes and anti-Stokes hyper-Raman scattering occur at 20vib, where vib is a vibration frequency. The selection rules differ from those of Raman scattering.
24
Electronic Raman scattering
Raman scattering can occur from electronic states, as well as from vibrations. At room temperature the bands are very broad, and merge into the background. At low temperatures (<80 K), the bands sharpen, and give information about the energies of electronic states of the molecule.
25
THANK YOU
Similar presentations
© 2024 SlidePlayer.com. Inc.