Presentation is loading. Please wait.

Presentation is loading. Please wait.

Presenter: Allen Duncan April 10, 2003. 2 Highlights of the Last Week Tested Receiver without optical link Used Al shield to determine EMI presence Conducted.

Similar presentations


Presentation on theme: "Presenter: Allen Duncan April 10, 2003. 2 Highlights of the Last Week Tested Receiver without optical link Used Al shield to determine EMI presence Conducted."— Presentation transcript:

1 Presenter: Allen Duncan April 10, 2003

2 2 Highlights of the Last Week Tested Receiver without optical link Used Al shield to determine EMI presence Conducted FFT analysis on Power Supply

3 3 Review of Last Presentation Better Results at 5 dB atten. when transmitter on. Is the signal we see crosstalk? 5 dB attenuation with TX OFF5 dB attenuation with TX ON

4 4 Remove Optical Link Q: Will Eye diagram remain w/out optical link? –A: YES No Optical Link PRBS7No Optical Link D21.5

5 5 Removing Optical Link Q: Eye diagram remains, What does this mean? –A: Cross-talk between Transmitter and Receiver is sufficient enough to create its own Eye Q: Does this cross-talk cause a problem in the functionality of the tranceiver? –This is yet inconclusive. A more sensitive PD, or stronger signal may overcome such X-Talk.

6 6 X-Talk experiments: Shielding Shielding between entire TX and RX Aluminum Shield Setup between TX and RX Eye Diagram with RX/TX shield

7 7 X-Talk experiments: Shielding Shielding specific components No Shielding VCSEL shielding SMA shielding PD shielding

8 8 X-Talk experiments: Shielding Shielding Conclusions –More evidence there is EMI between RX and TX –X-Talk Eye disappears only when RX and TX modules are completely shielded –When PD is shielded some degradation of signal is obtained but Eye is still visable

9 9 Power Supply Noise At least 2 frequencies present Noise on PS – at least 2 freq present Zoom of high frequency part of noise

10 10 More about noise and crosstalk Significant noise similar to that on the Power Supply was measured in the air as well Moving Foil Shield around produced weird results Eye diagram with Foil shield in random position

11 11 FFT Analysis Spikes at several Frequencies –~3 MHz –~330 MHz –~660 MHz –~1.25 GHz

12 12

13 13 Plans for the Coming Week Unconnectorized PD – Alignment tolerance Find and purchase more sensitive PD Determine solutions to no signal at 5 dB Determine ultimate role of X-Talk in disturbance of signal


Download ppt "Presenter: Allen Duncan April 10, 2003. 2 Highlights of the Last Week Tested Receiver without optical link Used Al shield to determine EMI presence Conducted."