Download presentation
Presentation is loading. Please wait.
Published byCorey Stewart Modified over 8 years ago
1
A Presentation on THERMAL POWER PLANT Sunil Kumar 11071024 M.E. (5TH)
2
INTRODUCTION In India 65% of total power is generated by the Thermal Power Stations. Yamunanagar Thermal Power Project i.e D.C.R.T..P.P(Deen Bandhu ChotuRam Thermal Power Plant) is a project of Haryana Power Generation Corporation limited (HPGCL). It is situated at village Kalanor In Yamunanagar. Its total capacity is 600 MW as at present with two units working with capacity. Having two unit of 2 x 300 MW = 600 MW
4
Boiler. Furnace. Turbine. Super Heater & Re- Heater. PA,FD & ID Fan. Cooling Tower MECHANICAL DESIGN
5
FUNCTION HELD IN PLANT 1.COAL FLOW 2.STEAM FLOW 3.WATER FLOW 4.ASH HANDLING
6
OPERATIONAL FEATURES INSIDE THE POWER PLANT
7
BOILER DRUM 2 3 5 1 6 4 LPH DEARATOR HPH APH COAL OIL FURNACE DRAFT SHRH ECONO- MISOR BFP CRH CEP CHIMNEY FD FAN HRH GENERATOR CONDENSOR HPT LPT IPT HOT SEC AIR COLD AIR TO PA FANS ID FAN PA FAN MILL
8
S.HEATER R.H. I.P L.P condenser H.P STEAM FLOW
9
WATER FLOW D.M. PLANT ECONOMIZER BOILERBOILER CONDENSERCONDENSER HOT WATER COOL WATER B.F.P STEAM COOLING TOWER
10
TURBINES AUXILIARIES VACUUM SYSTEM:- CONDENSER EJECTORS CW PUMPS CONDENSAT DEAERATORE SYSTEM: - CONDENSATE EXTRACTION PUMPS (CEP) LP HEATERS DEAERATOR
11
FEED WATER SYSTEM HIGH PRESSURE HEATERS BOILER FEED PUMP (BFP) FEED REGULATING STATIOIN DRIP & DRAIN SYSTEM
12
BOILER & IT’S ACCESSORIES BOILER DRUM SUPER HEATERS AIR HEATERS SUPRING LOADED SAFETY VALVES PRIMARY AIR CYCLE IGNITERS ECONOMIZER SUPER HEATERS REHEATERS
Similar presentations
© 2025 SlidePlayer.com. Inc.