Download presentation
Presentation is loading. Please wait.
Published byBryan Sullivan Modified over 8 years ago
1
PID detector and EMC for HIEPAF 邵明,唐泽波 核探测与核电子学国家重点实验室 中国科学技术大学近代物理系
2
MDC PXD/SSD PID-barrel PID-endcap EMC Coil York/Muon IP 3~6 cm 10 cm 15 cm 85 cm 105 cm 135 cm 185 cm 245 cm 120 cm140 cm190 cm240 cm300 cm 20
3
PID Detector
4
PID detector Key features Enable /K (and K/p) 3-4 separation up to 2GeV/c Suitable for high luminosity run – fast detector Radiation hard, especially in the endcap region Compact – reduce costs of the outer detectors Modest material budget - <0.5X 0
5
PID at low momentum Specific energy loss (dE/dx) in the gaseous tracking detector (MDC) can be used for low momentum PID Better dE/dx resolution for longer track length Example: ~6% at BESIII MDC (track length ~0.7m) clean /K/p ID for p<0.8/1.1 GeV/c
6
Time of Flight? / = T/T = m 2 /2p 2 T =L/c * m 2 /2p 2 ~ L/c * m 2 /2p 2 For /K/p at p=2GeV/c, T ~ 0.1ns*L(m) = 100/270 ps at L~1m. So for 3 /K/p separation an overall TOF time resolution ~20/50ps is needed. TOF alone can not identify /K to p=2GeV/c
7
Cherenkov detector Cherenkov radiation: Radiation if particle velocity larger than speed of light in medium Commonly used in HEP experiment to identify particles at high momentum Two catalogs – Threshold Cherenkov – simple to build – Imaging Cherenkov: RICH(large momentum range)/DIRC/TOP(most compact)
8
Baseline Design PID by RICH at 0.8<p<2GeV/c, no TOF Proximity RICH, similar to ALICE HMPID design, but with PHENIX HBD (CsI coated GEM) readout n~1.3 (liquid C 6 F 14 ), UV detection Already proven Immune to B field same structure at both the endcap and the barrel ALICE HMPID PHENIX HBD
9
Relevant formulae and figures Take n=1.13/1.3 and N photon =10 ~60/38 mrad single photon resolution is needed for 3 /K separation at p=2GeV/c correspond to ~20/14mm photon sensor size (with proximity gap T=10cm)
10
Expected performance Cherenkov angle vs. track momentum in p-Pb data ALICE HMPID Liquid C 6 F 14 radiator n~1.3 @ 175nm Proximity gap = 80mm readout pad size 8mm 8.4mm 3 /K/p separation up to p=3/5 GeV/c
11
Alternative Design No TOF, PID by RICH only Similar to BELLE-II ARICH design, Aerogel + Position Sensitive Photon Detector n~1.13 (Below threshold for proton at p<2GeV/c) Already proven at the BELLE-II endcap, how about the barrel part? Need R&D Proximity focusing
12
BELLE-II ARICH performance double aerogel, n 0 =1.055,1.065 Proximity gap = 200mm c =336mrad =15.8mrad N det = 11.4 >5.5 σ /K separation at 4 GeV/c BELLE-II ARICH ~ 5mm photon sensor size
13
Radiator index choice No K/p separation at 1.1-1.5 GeV/c n>1.1 to separate K/p Aerogel is a choice in this index range only , K , K, p /K MDC K/p MDC
14
Electromagnetic Calorimeter
15
MDC PXD/SSD PID-barrel PID-endcap EMC Coil York/Muon IP 3~6 cm 10 cm 15 cm 85 cm 105 cm 135 cm 185 cm 245 cm 120 cm140 cm190 cm240 cm300 cm 20 Crystal + Photosensor
16
EMC Requirements Good energy resolution Good position/angular resolution Good timing resolution if possible BaBar CsI(Tl) + PIN
17
Challenging at high luminosity era Radiation damage – Decrease light yield – A function of run time High photon background rate – Produce pile-up – Degrade energy and angular resolution Babar, NIM A479 (2002) 1 0.75 krad 1.2 krad Behavior of the light emitted by a crystal due the radiative Bhabha photons
18
Requirement at high luminosity era Short decay time Radiation hard High signal-to-background ratio
19
Crystal comparison
21
Pros and Cons of BSO Pros: Relative fast Radiation hard Emission spectrum peak at 480 nm Small X0 (60% CsI) more compact Small Moliere Radius (60% CsI) finer segmentation Low raw material cost (~PWO and 50% BGO, much less than LYSO) Cons: LY smaller than CsI(Tl) and LYSO (however, ~ PWOII at -25 0 C) Dose rate dependent LY, fast recovery time LY Calibration system needed Not mature (large size available, mass production not proven)
22
BSO performance 9 crystals from SICCAS, 2x2x20 cm 3 Measured with XP2262 Caltech
23
Energy resolution contribution Not only light yield matters 100 p.e./MeV 1% @ 100 MeV Noise is important at not very high energy CMS PWO E -1 E -1/2
24
Noise term Energy E photons ElectronsElectronics Crystal Light Yield LY Photosensor Gain G Noise at the readou chain dV dE ~ dV/G/LY/E High gain and high light yield Smaller equivalent noise energy Better resolution, especially at low and moderate energy
25
Photosensors PIN Photodiode Mature Large noise/signal Large Area APD Relatively Mature Large noise/signal Vacuum photopentode New, under developing Low noise, low gain (~10-100) Sensitive to magnetic field Multi-Pixel Photon Counter (MPPC/SiPM) New, under developing High gain (~10 6 ), low ENE, simplify electronics Insensitive to magnetic field Good timing resolution
26
MPPC/SiPM test Hamamatsu S10362-33-050C 3 x 3 mm 2 Crystal 3 x 3 x 15 mm 2
27
ray spectrum 0.662 MeV 0.511 MeV 1.275 MeV
28
Linearity and resolution BGO
29
Energy resolution BGO CsI(Tl) A few % resolution achieved at ~1 MeV ~ 1.26/sqrt(N pe ), still room to improve BGO CsI(Tl)
30
BGO CsI(Tl) Energy resolution comparison BaBar Cs(Tl)+PIN SuperB LYSO+APD Belle2 pure CsI+PP +SiPM PANDA PWO@-25 0 C+APD
31
0.511 MeV energy resolution BGO+SiPM S:13% 8.5% BGO + SiPM: 13%*2.354 = 31% CsI(Tl)+SiPM: 6%*2.354= 14% LYSO+SiPM: 5%*2.354= 12% LSO/LYSO + PMT: 11-21% LSO/LYSO + APD: 26-43% Gate: 1000 ns L.O. = 190 p.e./MeV 2.5 x 2.5 x 20 cm 3 0.3 x 0.3 x 1.5 cm 3 SuperB TDR
32
SiPM/MPPC products sensL 4 x 4 channel array 3 x 3 mm 2 each channel 4774 cells per channel ~ €120 Hamamatsu 4 x 4 channel array 3 x 3 mm 2 each channel 3600 cells per channel ~ ¥ 1500
33
Summary PID detector – RICH only, no TOF – C 6 F 10 as radiator + CsI-GEM – Aerogel as radiator + HAPD/MPPC Calorimeter – Fast crystal with reasonable LY is needed (BSO, or PWO?) – Photosensor with high gain to overcome LY decrease – MPPC/SiPM significantly suppress the noise term BGO+SiPM : <9% @1.275 MeV CsI(Tl)+SiPM : <4% @1.275 MeV Thanks!
35
Cost? ITP, Beijing, Feb. 19, 201435 Zebo Tang, USTC L L SuperB (Italy) Forward EMC cost estimation BSO crystal price expected to be ½ of BGO, ~PWO Cost of Crystal + photosensor + LY calibration system LYSO : Pure CsI : BGO : PWO : BSO 8.1 : 3.1 : (4-5.4) : (2.5-3.9) : (2.7-4.1) or 4.0 Pure CsI readout by APD PP 3x price of APD SuperB TDR, 2013
36
Relevant formula Threshold: Emission angle: Photon yield:
38
Threshold Cherenkov + TOF Design A threshold Cherenkov detector ( /K), plus a TOF Similar to BELLE ACC design n~1.03, TOF resolution ~90ps Technically simple But need more space to accommodate more materials Plastic scintillator + PMT or MRPC can be used for TOF Threshold Cherenkov detector module
39
Expected performance n = 1.030, /K separation 0.8- 2.5GeV/c n = 1.010, /K separation 1.0- 3.5GeV/c BELLE ACC
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.