2D Transient Overview. 4/20/04, pg. 2 2D Transient  Introduction and Theory  Source Types  Source Waveforms  Time-varying materials  Solution Setup.

Similar presentations


Presentation on theme: "2D Transient Overview. 4/20/04, pg. 2 2D Transient  Introduction and Theory  Source Types  Source Waveforms  Time-varying materials  Solution Setup."— Presentation transcript:

1 2D Transient Overview

2 4/20/04, pg. 2 2D Transient  Introduction and Theory  Source Types  Source Waveforms  Time-varying materials  Solution Setup  Mechanical Setup  Results  General Suggestions

3 4/20/04, pg. 3 Introduction to 2D Transient  Transient “time-stepping” or “time-domain” solver  Coupled FEA with external circuits and motion equations  Allows non-sinusoidal current or voltage excitation  Allows rotational or translational motion  Links with external user control program  Comprehensive results

4 4/20/04, pg. 4 Application Examples  Motors/ Generators (RMxprt)  Variable Reluctance Sensors  Eddy Current Braking  Frictionless Bearings/Actuation  Inductors/Transformers  Solenoids

5 4/20/04, pg. 5 Fully Coupled Dynamic Physics Solution Time-varying Electric and Magnetic Fields Permanent MagnetMagnetic Vector Potential VelocityElectric Scalar PotentialCurrent Source Density

6 4/20/04, pg. 6 Types of Induced Eddy Currents  Within source conductors (skin effect)  Resulting from a stationary AC field diffusing into a nearby conductor (proximity effect)  Resulting from the motion of a DC source, such as a magnet, near a conductor (proximity effect)  A combination of all three above (the most complex)

7 4/20/04, pg. 7 Magnetic Field Diffusion  Magnetic fields “diffuse” into materials at different rates depending on:  Material properties of the component  Physical size of the component  For a cylindrical conductor, diffusion time is:  Induced eddy currents always occur in conducting objects due to time-varying fields; however, they may not always be significant

8 4/20/04, pg. 8 Time varying Input Parameters  Conductor Sources  Load Conditions  Electrical Parameters and Components  Mechanical Parameters and Components  Linear Material Properties

9 4/20/04, pg. 9 Freely Defined Behavior  Constants  Functions (Expressions)  Numeric  Algebraic  Trigonometric  Input Data File (Piecewise linear)

10 4/20/04, pg. 10 Meshing for Rotational Motion  “Moving Surface” method used

11 4/20/04, pg. 11 Meshing for Rotational Motion Rotor Stator Band Air gap

12 4/20/04, pg. 12 Meshing for Translational Motion  “Moving Band” method used  Re-mesh band area at each time step  Stationary region and moving part(s) are not re-meshed Moving part(s) Band Stationary region

13 4/20/04, pg. 13 Comprehensive Results  Solution Parameters vs. Time  Back EMF, Flux Linkage, Power Loss, Terminal Voltage, Winding Current  Force, Torque, Position, Speed  Error  Field Evaluations at an Instant of Time  Single instant  Numerous field solutions can be viewed at a user defined interval

14 4/20/04, pg. 14 Additional Key Features  Solution Pause/ Re-Start Feature  Refresh Solution Parameters

15 4/20/04, pg. 15 Comparison of 2D Products  Electrostatic, Magnetostatic, Eddy Current  Steady State Solvers (DC and frequency domain)  Equivalent Circuit Generator  Series of DC solutions at instants (or snap-shots) in time  Partially dynamic solution  Concentrates on saturation and back-emf effects  Can evaluate design alternatives with parametrics  No time-induced field effects are considered!  2D Transient  Completely dynamic solution (time domain)

16 4/20/04, pg. 16 Types of Sources - Overview  Current, voltage, and external sources are available  Two conductor types:  Solid - eddy currents  Stranded - no eddy currents considered

17 4/20/04, pg. 17 Types of Sources Note: for stranded conductors  Need to select both Go and Return objects together  Need to define “winding setup” as the total phase winding seen from the terminals

18 4/20/04, pg. 18 Solid Current or Voltage Source  A solid current source (total Amps only) can be functional or constant  A solid voltage source (total Volts only) is assumed to be the total voltage drop over the length of a conductor. Voltage drops can be functional or constant; however, the potential is constant over the entire cross-section of the conductor

19 4/20/04, pg. 19 Stranded Current Source Winding Setup  Specify polarity of each object as positive, negative, or function  Specify total turns as seen from terminal  Specify number of parallel branches as seen from terminal

20 4/20/04, pg. 20 Stranded Voltage Source Winding Setup  Specify polarity of each object as positive, negative, or function. A function will be used for brush type motors to handle commutation. The value of polarity is either 1 or -1. In general df = f (T,S,P)  Make the polarity index, df, a function of position (0, 360 deg). Whenever a coil passes over a stationary brush, the change of its polarity is used to indicate the transition from one coil group to the other  Use commutation interval to represent the actual brush size  Use different transition curves to describe different commutation processes

21 4/20/04, pg. 21 Stranded Voltage Source Terminal Attributes  Initial Current: used if motor is running at t=0  Resistance: DC resistance of the winding or additional external resistance, f (S, T, P)  Inductance: End turn or additional external inductance, f (S, T, P)  Capacitance: External capacitance, such as a starting capacitor in a single phase induction motor used to change capacitance as a function of speed, time, or position  Y-connect: Used for three phase machines to indicate that the windings are Y-connected and have NO neutral return (Ia + Ib + Ic = 0)  Specify total turns as seen from terminal  Specify number of parallel branches as seen from terminal NOTE: R, L, and C are assumed to be connected in SERIES at end of the terminal

22 4/20/04, pg. 22 External Connection  Choose External Connection  Can be either solid or stranded  Value field is not active. The value will be determined by the external circuit.

23 4/20/04, pg. 23 External Connection Winding Setup  For winding setup specify:  Polarity  Initial Current  Total Turns and the number of Parallel Branches

24 4/20/04, pg. 24 External Connection  Windings are represented in the Schematic Editor as a 1H inductor The dot represents the positive terminal

25 4/20/04, pg. 25 External Connection  To complete the winding definition, you need to add the DC resistance and any end leakage inductance or line inductance. This inductor is automatically included. It represents the B phase winding in the FEA model; the value of 1H is neglected. This is the DC resistance of the entire B phase winding. This inductor represents the end turn leakage inductance of the entire B phase winding.

26 4/20/04, pg. 26 Create Custom Drive Circuit! Freewheeling Diode A Phase Winding Diode and Switch combination acting as a transistor Current and Voltage Probes B Phase Winding Position dependent sources to toggle switches S1-S8 Elements: R, L, C, Diode, and Switches (V & I) 3 Diode types: Default, Rectify, Freewheel Sources: V & I as a function of Time, Speed, or Position

27 4/20/04, pg. 27 External Circuit Position Dependent Source 45 0.1 Voltage Mechanical Degrees 0.1 44.9 One Voltage Pulse 1.0 22.45 These values represent position in mechanical degrees, even though labeled as [s] When you exit the Schematic Editor - indicate Time, Position, or Speed Dependent

28 4/20/04, pg. 28 Source End Connections  Multiple objects must be selected  Used primarily for passive conductors (with no source current assigned) such as squirrel cage induction machines to indicate that the group of objects selected are connected together  The resistance and inductance between selected objects is specified with following assumptions: 1. The connections are periodic 2. There are no breaks in the end ring 3. These values are constant only

29 4/20/04, pg. 29 Source Waveforms Overview 2D Transient Excitation Waveforms  Static DC Current  Steady State Sinusoid  Steady State Square Wave  Steady State Triangle Wave  Composite  PWM Waveform  Arbitrary Piecewise Linear Table

30 4/20/04, pg. 30 Source Waveforms DC Pulse Square Wave Sinusoidal Triangle Wave

31 4/20/04, pg. 31 Source Waveforms Composite Waveform PWM Arbitrary

32 4/20/04, pg. 32 Functional Source Summary  Current and voltage sources (solid or stranded) can be constant or functions of time, position, or speed  Auxiliary and Main winding can be a function of time, a good choice for single and multi-phase machines.  For DC machines, it’s often better to use sources as a function of position. Here a new expression in the function evaluator is used: pwlx

33 4/20/04, pg. 33 Time-varying materials Functional conductivity based on speed

34 4/20/04, pg. 34 Time-varying materials T - Time (seconds) P - Position (degrees) S - Speed (rpm or deg/sec)  Bar_Cond: conductivity changes as a function of speed. In the locked rotor case where the motor usually runs a little warmer,  = 2.68e7 (S/m) and increases linearly until rated speed (3600 rpm) where its value is 2.96e7 (S/m).  Single_Bar: Here the conductivity switches from 2.68e7 to zero (S/m) to simulate a broken rotor bar at 0.1 seconds.

35 4/20/04, pg. 35 Summary of Functional Variables Source variablesSolid Conductor Variables The following range of functional source variables are available for their respective conductors: The following range of functional variables are available for solid conductors: Perfect ConductorTotal current sourceFunc(p, s, t)ConductivityFunc(x, y, p, t) Solid ConductorCurrent Source Voltage Source Func(p, s, t) End ResistanceMust be constant Stranded ConductorCurrent Density Current Source Voltage Source Func(x, y, p, t) Func(p, s, t) End InductanceMust be constant Winding VariablesMechanical Transient Variables The following range of functional variables are available for windings: The following functional variables are available for mechanical transient setups: PolarityFunc( p, s, t)SpeedFunc(p, s, t) ResistanceFunc(p, s, t)LoadFunc(p, s, t) InductanceFunc(p, s, t)FrictionFunc(p, s, t) CapacitanceFunc(p, s, t)

36 4/20/04, pg. 36 Setup Solution Options  MUST manually create a mesh - No remeshing for entire solution  Stop and Restart capability  Fixed time step is typically 20-50 steps per electrical cycle  Adaptive time step needs an initial, maximum, and minimum timestep  Specify save fields time step by clicking on Setup…  Model depth (in user units)  Symmetry multiplier for periodic models (quarter model uses 4)  Identify custom User Control Program  Identify post processing macros  Output energy error is desired

37 4/20/04, pg. 37 Setup Solution Motion Setup  Three types of Objects: 1. Stationary 2. Band 3. Moving  Set Band: all objects inside of Band object are automatically chosen and are assumed to be moving together  Select type of Motion, center of rotation, limits, and initial position.

38 4/20/04, pg. 38 Mechanical Setup  Check “consider mechanical transient” unless objects are stationary or have constant speed  Set units of speed. If degrees/sec isselected, then all functions set previously that depend on speed will be in deg/sec. The other option is rpm.  Enter moment of inertia (for rotational motion) or mass (for translational motion)  When performing a mechanical transient simulation, damping and load torque (or load force) can be a function of f (T, S, P). Note: While inertia is automatically calculated by the simulation, gravity must be separately entered as a load torque or load force

39 4/20/04, pg. 39 Functional Mech Examples Load Torque T(N-m)

40 4/20/04, pg. 40 2D Transient Results  Transient plots can be viewed by selecting Solutions/ Transient Data  Fields can be viewed at a particular time step by selecting Post Process/ Fields...  Transient plots can be opened, modified, and combined by selecting Post Process/ Transient Data...

41 4/20/04, pg. 41 Transient plot

42 4/20/04, pg. 42 Field plot from Post Processor

43 4/20/04, pg. 43 Combined transient plot

44 4/20/04, pg. 44 General Suggestions  Manual Mesh - transient solution relies on the creation of a ‘sound’ manual mesh  Distribution should be as even as possible  Total number of elements should be adequate  Time Step  Each problem will have an ‘optimum’ step  User must experiment to get suitable value  Large Motion  Re-meshing inside “band” required with linear motion  Mesh density inside “band” must be fine


Download ppt "2D Transient Overview. 4/20/04, pg. 2 2D Transient  Introduction and Theory  Source Types  Source Waveforms  Time-varying materials  Solution Setup."