1 23MAY07Xvc - Calo ECS Working Group1 Calo FSM hierarchy and structure Xvc

2 23MAY07Xvc - Calo ECS Working Group2 Calorimeter Control Structure DAQ –SPECS –CCPCs – TELL1 DAI –Crate LVPS DCS –LVPS – Wiener Maraton –CAN – Temperature –Cooling HV –SPECS – LED system

3 23MAY07Xvc - Calo ECS Working Group3 Calorimeter Control Structure SPECS –Radiative Source CAN bus –1 PC Power Supply Control –1 PC BusesMasters PCs CACA CA HV+LEDCrateHV+LEDCrate HCAL 121211 11 ECAL 373733 11 PRS-SPD 141422 11 Total 5135 66 33 18 12 6

4 23MAY07Xvc - Calo ECS Working Group4 LVPS – Wiener RCM distribution A-side Rack B1B01 Crate B1B01F05 SlotNameIP addressSystemRack 1Crate 1Rack 2Crate 2 1psmatn04.lbdaq.cern.ch10.130.36.167PRS/SPDL3B11PRS4L3B12PRS5 2psmatn05.lbdaq.cern.ch10.130.36.168PRS/SPDL3B13PRS6L3B14PRS7 3ecmatn05.lbdaq.cern.ch10.130.36.176ECALL3B11ECAL15L3B11ECAL16 4ecmatn06.lbdaq.cern.ch10.130.36.177ECALL3B12ECAL17L3B12ECAL18 5ecmatn07.lbdaq.cern.ch10.130.36.178ECALL3B13ECAL19[not connected] 18ecmatn08.lbdaq.cern.ch10.130.36.179ECALL3B14ECAL20L3B14ECAL21 19hcmatn03.lbdaq.cern.ch10.130.36.170HCALL3A13HCAL24L3A13HCAL25 20hcmatn04.lbdaq.cern.ch10.130.36.171HV/LEDL3B11 HV/LED ECAL AL3A13HV/LED HCAL A 21psmatn06.lbdaq.cern.ch10.130.36.169 PRS/ SPD VFEL3B13 PS/SPD VFE AL3B13PS/SPD VFE A

5 23MAY07Xvc - Calo ECS Working Group5 LVPS – Wiener RCM distribution C-side Rack B1B01 Crate B1B01F33 SlotNameIP addressSystemRack 1Crate 1Rack 2Crate 2 1 psmatn01.lbdaq.cern.ch 10.130.36.161PRS/SPDL3B04PRS0L3B03PRS1 2psmatn02.lbdaq.cern.ch 10.130.36.162PRS/SPDL3B02PRS2L3B01PRS3 3ecmatn02.lbdaq.cern.ch10.130.36.173ECALL3B04ECAL8L3B04ECAL9 4ecmatn03.lbdaq.cern.ch10.130.36.174ECALL3B03ECAL10 5ecmatn04.lbdaq.cern.ch10.130.36.175ECALL3B02ECAL11L3B02ECAL12 17ecmatn01.lbdaq.cern.ch10.130.36.163ECALL3B01ECAL13L3B01ECAL14 18hcmatn02.lbdaq.cern.ch 10.130.36.164HCALL3A03HCAL22L3A03HCAL23 19hcmatn01.lbdaq.cern.ch10.130.36.165HV/LEDL3A03 ECAL HV/LED CL3B01 HCAL HV/LED C 20psmatn03.lbdaq.cern.ch10.130.36.166 PRS /SPD VFEL3B03PS/SPD VFE CL3B03PS/SPD VFE C 21SPARE

6 23MAY07Xvc - Calo ECS Working Group6 Agilent Power Supplies Rack D3B04 SystemNameIP address ECAL four units PS (100V, 30V,100V, 30V for A and C sides);hcagil01.lbdaq.cern.ch10.130.36.151 HCAL four units PS (100V, 30V,100V, 30V for A and C sides);ecagil01.lbdaq.cern.ch10.130.36.152 PS/SPD one unit PS (150V for side A);psagil01.lbdaq.cern.ch10.130.36.153 PS/SPD one unit PS (150V for side C);psagil02.lbdaq.cern.ch10.130.36.154 PS/SPD two units PS (18V, 18V for side A and C);psagil03.lbdaq.cern.ch10.130.36.155

7 23MAY07Xvc - Calo ECS Working Group7 Top Calorimeter Hierarchy

8 23MAY07Xvc - Calo ECS Working Group8 TOP PreShower Hierarchy

9 23MAY07Xvc - Calo ECS Working Group9 PRS_DAQ

10 23MAY07Xvc - Calo ECS Working Group10 XCAL_DAQ

11 23MAY07Xvc - Calo ECS Working Group11 Comments No Side Partition Crates can be individually selected Subdetector projects will run on SPECS PCs (either A or C side) HCAL_DCS shall include the radiative source Global calorimeter control units will run –HCAL SPECS PC –CALO DCS PC –Whichever is less loaded Groups should deliver device units Hierarchy is centrally set up