— Analog Devices Confidential Information — Applications Issues 1.

Similar presentations


Presentation on theme: "— Analog Devices Confidential Information — Applications Issues 1."— Presentation transcript:

1 — Analog Devices Confidential Information — Applications Issues 1

2 — Analog Devices Confidential Information — Applications Issues: Powering up the HDMI Tx  When Hot-Plug Detect (HPD) is low the HDMI Tx will automatically go into power down mode.  After an HPD interrupt, register 0x41[6] must be set to ‘0’ to power up the part  During power down all registers except for 0x97 – 0xAF are reset to defaults  Most HDMI Tx devices (except AD9889, AD9389, AD9387, ADV7520, ADV7521) have an "HPD Override" function  These devices will operate same as if HPD = 1 when HPD "override" is enabled  On the ADV7510, the registers will reset on an HPD = 1 -> 0 transition  On the rest of these HDMI Tx devices the registers will not reset on an HPD = 1 -> 0 transition  HPD state and interrupt registers remain available even if HPD Override is enabled 2

3 — Analog Devices Confidential Information — Applications Issues: Clock Delay Adjustment  When input data to clock skew is not ideal, the clock delay can be adjusted in the HDMI Tx  For ADV7520 and later DDR falling edge can be adjusted independently DelayRegister 0xBA[7:5] -1200 ps000 -800 ps001 -400 ps010 No Delay011 400 ps100 800 ps101 1200 ps110 Inverted111 3

4 — Analog Devices Confidential Information — Applications Issues: EDID reading wait time  To ensure that the EDID/HDCP controller has sufficient time to read the EDID from the sink, the system software should wait a certain amount of time before judging that there is no EDID  The time recommended is based on 256 byte of DDC bus reading at 20KHz clock rate  This gives the minimum recommended time out period of 256 bytes x 10 cycle per byte x 50us = 128ms To make system more robust, 0.5s is recommended to allow at least 3 EDID reading tries. 4

5 — Analog Devices Confidential Information — Applications Issues: High Speed I2C Bus  ADV7523 and later support 400kHz I2C operation. ADV7511, ADV7523A, ADV7524A, ADV7525, ADV7541 Register 0xE6[1] must be set to 0 If 0xE6[1] is not set interrupt registers and mask registers are not reliable  All earlier Tx only support up to 100kHz I2C AD9x89, AD9387, ADV7510, ADV7520, ADV7521 5

6 — Analog Devices Confidential Information — Common Apps Issues - HDCP  HDMI Tx contains a robust HDCP controller  Most HDCP timing is handled internally  All devices pass the official HDCP compliance test  Common Causes for HDCP problem Ri Mismatch  Problem with HDCP keys Some Tx need the internal key selected by a register setting Some Tx need an external EEPROM  Vsync not stable I2C NACK  Problem with DDC line capacitance  Extremely Long Cable 6

7 — Analog Devices Confidential Information — Common Apps Issues – Debugging HDCP  Make sure PLL locked register is always 1  Try probing the Vsync, DE, and Hsync inputs to the HDMI Tx Are there any glitches? A glitch would cause the mask on the Tx and Rx to mismatch HDCP “snow” would result until the Ri mismatch causes reauthentication  If using AD9389B or ADV7520 make sure 0xBA[4] is set to 1.  If HDCP problems still exist probe the DDC lines to find exactly where the problem is Scope with I2C software Beagle I2C Analyzer 7

8 — Analog Devices Confidential Information — Common Apps Issues – Video Input Formatting  Requires communication between customer HW and SW engineers Many pin connection options are available Options for Hsync, Vsync, and DE input are available  Separate Hsync, Vsync, and DE  Embedded Syncs  Hsync and Vsync only  Requires an understanding of the part feeding the video’s format specification Many chips output a format that will work with an encoder but requires special handling for HDMI 8

9 — Analog Devices Confidential Information — Quick Check for Input formatting problems  PLL Status Register Check several times continuously If PLL is not locked check the signal integrity of the video clock and R_EXT noise  Input VIC Detected Register If a CEA861 format is used the VIC code should be available If “0” is present, then the input format is not recognized 9

10 — Analog Devices Confidential Information — PLL Lock Issues  A common issue is PLL not locking  This can be verified by checking register 0x9E[4]  Until 0x9E[4] = 1, focus on hardware  Generally there are 2 causes Ringing on the CLK input Low frequency noise near the R_EXT resistor  Solutions Make sure all fixed register settings match recommendations Add 100ohm serial resistor near the clock source Reduce drive strength on the clock Check layout for DDC lines or other low speed lines crossing the R_EXT traces 10

11 — Analog Devices Confidential Information — 480i input  If customer is using a 480i format  Best option is to have EAV and SAV timing matching the diagram on left  ADV752x and ADV7510 have flexible timing options allowing conversion to CEA 861 line noFV 52501 22 2101 2200 Valid Video Area field 1 240262 26100 26211 23 28411 28610 Valid Video Area field 2 240 263 52410 11

12 — Analog Devices Confidential Information — Common Apps Issues – Audio Input Formatting  Low power Tx use SPDIF or I2S AD9889B does not support 32 clock per fs format I2S 4 different formats are supported on the I2S pins  Compressed Audio Compressed audio is passed as is through the Tx No processing Done Channel Status must be included  Dolby 5.1, DTS, Dolby Plus and DTS HRA are the same from HDMI Tx perspective  SPDIF is the easiest method for sending compressed audio  Special I2S mode with embedded channel status can also be used 12

13 — Analog Devices Confidential Information — Common Apps Issues – Audio Input Formatting  ADV7510 and ADV7511 Support High Bit Rate Audio Compressed streams over 6.144mbs Dolby True HD and DTS Master are the popular formats These look the same from the HDMI Tx perspective  Input Always uses the I2S lines Can use I2S style or SPDIF style input For inputs besides ADI Rx subpacket mapping may need to be modified 13


Download ppt "— Analog Devices Confidential Information — Applications Issues 1."

Similar presentations


Ads by Google