1 VARITECTOR SPC Signal Pluggable Connection Surge Protection for Control and Instrument

2 Installation size with pluggable arrester for surge protection in C&I applications Width: 17.5 mm 88 mm 80 mm 17.5 mm pitch design Pluggable arrester Indicator for fault out signalling Base socket with up to 12AN screw type connection Surge protection with PE rail contact Coding element for each type inside the arrester Colour code on the top of the arrester (see the colour code table) Marking for “unprotected” and “protected” on the side and as an arrow on the top of the base socket Accessories: EMC connector Standard Marker DEK5

3 Symmetrical Loop 2 Signals  VSPC binär 2 Signals 5Vdc 0,5A; 8924200000  VSPC binär 2 Signals 12Vdc 0,5A; 8924220000  VSPC binär 2 Signals 12Vac 0,5A; 8924240000  VSPC binär 2 Signals 24Vdc 0,5A; 8924320000  VSPC binär 2 Signals 24Vac 0,5A; 8924340000  VSPC binär 2 Signals 48Vac 0,5A; 8924360000  VSPC binär 2 Signals 60Vac 0,5A; 8924380000 SL

4 Symmetrical Loop 4 Signals  VSPC binär 4Signals 5Vdc 0,5A; 8924210000  VSPC binär 4Signals 12Vdc 0,5A; 8924230000  VSPC binär 4Signals 12Vac 0,5A; 8924250000  VSPC binär 4Signals 24Vdc 0,5A; 8924330000  VSPC binär 4Signals 24Vac 0,5A; 8924350000  VSPC binär 4Signals 48Vac 0,5A; 8924370000  VSPC binär 4Signals 60Vac 0,5A; 8924390000 SL

5 Symmetrical Loop 2 Signals  VSPC binär 2 Signals 5Vdc 0,5A; 8924200000  VSPC binär 2 Signals 12Vdc 0,5A; 8924220000  VSPC binär 2 Signals 12Vac 0,5A; 8924240000  VSPC binär 2 Signals 24Vdc 0,5A; 8924320000  VSPC binär 2 Signals 24Vac 0,5A; 8924340000  VSPC binär 2 Signals 48Vac 0,5A; 8924360000  VSPC binär 2 Signals 60Vac 0,5A; 8924380000 SL

6 Symmetrical Loop 4 Signals  VSPC binär 4Signals 5Vdc 0,5A; 8924210000  VSPC binär 4Signals 12Vdc 0,5A; 8924230000  VSPC binär 4Signals 12Vac 0,5A; 8924250000  VSPC binär 4Signals 24Vdc 0,5A; 8924330000  VSPC binär 4Signals 24Vac 0,5A; 8924350000  VSPC binär 4Signals 48Vac 0,5A; 8924370000  VSPC binär 4Signals 60Vac 0,5A; 8924390000 SL

7 RS 485 with floating ground function  VSPC RS 485; 8924670000

8 2x UKo  VSPC ISDN Uko; 8924660000

9 2x UKo with floating ground

10 V-Control Unit -Module for the signalling to the control station -Maximum 10 VSPC could be installed inside the monitoring circuit -Signalling of the defect of the VSPC inside the loop -Signalling of wire break inside the signalling loop -One change over switch for the signal -Internal LED for ok or defect monitoring -Flashing of both LEDs if the signal loop is defect

11 V-TEST – Test unit -Frequently control of the external and internal surge protection. This requirement is written in the IEC 62305. -With the V-Test unit we fulfil the requirements Transportable product Inclusive a rechargeable battery Test function for PU I, PU II and VSPC All new articles are inside of the device Additional products can be filled in by the user it self

12 EMC-Set -Fast connection of the shield inside the terminal -Different parts of the EMC-Set: EMC-Setarticle number: 1067470000 EMC-Connectorarticle number: 1067520000 EMC-Tiearticle number: 1067490000 Tool RT-1article number: 1296000000 -3 steps to success! Put the EMC-Connector inside the clamping yoke Cable with shield inside the EMC-Connector and fixing of the different wires EMC-Tie around the shield and EMC-Connector and fixing of the tie with the tool RT-1

13 VARITECTOR SPC Easy for maintenance - Pluggable, uniform housing to PU Series - Test box for checking the products Wide range of products: protect: binary signals, current loops and data signals (around 60 products) Universal use In floating or grounded loops Plug and Play pluggable PE contact to the DIN Rail TS35 Space saving: - 2 current loops on 17,8mm  8,9mm/signal - 4 binary signals on 17,8mm  4,4mm/signal - Smaller than the competitors by using non-powered loop Intrinsic safe application: ATEX EEx ia IIC T6 approval Easy handling of the screen: use a standard KLBÜ Monitoring - fault indication - for the binary modules red/green signal - signaling contacts for external monitoring

14 VARITECTOR SPC Surge Protection for C&I Signals pluggable Inst Housing in the same design of the PU I, PU II and PU III protection for binary, analogue and data signals (~ 60 products) indication by LED ( red / green) test equipment V-TEST for the IEC 62305 Fulfil the latest standard IEC 61643-21 and can be used / installed by the application standard IEC 61643-22 direct ground or floating ground via TS 35 connection to PE, up to 20kA (8/20μs) save space: 2 current loops with monitoring @ 17,8mm (8,9mm/ Signal) 4 Binary Signals with monitoring @ 17,8mm (4,4mm/ Signal) We will replace the old EGU and LPU family