Download presentation
Presentation is loading. Please wait.
Published byHester Rogers Modified over 8 years ago
1
n νeνeνeνe p+p+ e-e- The Proton Spectrum in Neutron Beta Decay: Latest Results with the a SPECT Spectrometer The a SPECT collaboration Universität MainzF. Ayala Guardia, M. Borg, W. Heil, R. Muñoz Horta, Y. Sobolev, G. K. Universität KarlsruheF. Glück TU MünchenI. Konorov, H.-F. Wirth ILL GrenobleK. Leung, M. Simson, T. Soldner, O. Zimmer University of VirginiaS. Baeßler Gertrud Konrad International Conference on Particles And Nuclei PANIC08 Eilat, Israel, 9 - 14 November 2008 University of Mainz / Germany
2
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 Outline Measurement of the Neutrino-Electron Correlation Coefficient a The Neutron Decay Spectrometer a SPECT Results from the beam times at FRM-II, Garching (2006) and at ILL, Grenoble (Spring 2008) Summary and Outlook
3
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 Neutron Decay Parameters (SM) Jackson et al., PR 106, 517 (1957) n νeνeνeνe p+p+ e-e- Neutrino-Electron Correlation Neutron lifetime Beta-Asymmetry Weak coupling constant ratio
4
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 Neutrino-Electron Correlation a and Proton Spectrum in Free Neutron Decay The Correlation Coefficient a Proton kinetic energy is big n νeνeνeνe p+p+ e-e- n νeνeνeνe p+p+ e-e- Proton kinetic energy is small n νeνeνeνe p+p+ e-e- θ Sensitivity of the Proton Spectrum to a 0200400600 Proton spectrum for a = + 0.3 and for a = - 0.103(4) (PDG 2008) Proton kinetic energy E [eV] Decay rate w(E) Present best experimentsΔa/ a ~ 5% Aim of a SPECT Δa/ a ~ 0.3%
5
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 Setup of a SPECT at PF1b/ ILL Analyzing Plane Electrode Proton detector Neutron decay Protons Magnetic field Anti-magnetic screen
6
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 Spectrometer Sketch and Principle of a Retardation spectrometer Transmission function T U (E) in the adiabatic limit: Neutron Beam +1kV (0V to +800V) -30kV Proton Detector Electrostatic Mirror Decay Volume Analyzing Plane B A ≈ 0.44T B 0 ≈ 2.2T U ExB 0200400600 Proton kinetic energy E [eV] Decay rate w(E) Transmission function @ U = 375V 0.0 0.2 0.4 0.6 0.8 1.0 Transmission function T U (E) Adiabatic conversion Proton spectrum for a = + 0.3 and for a = - 0.103(4) (PDG 2008)
7
Test run at FRM-II: Background influence on a and possible explanation (Penning traps) Each data point corresponds to an independent measurement run. Neutron Beam -30kV Proton Detector Decay Volume Analyzing Plane ExB Trapped e - Background measured @ U A = 780V Strategies to reduce the background New detector with better energy resolution Avoid fluctuating background due to trapped particles: Reduce field-emission, e.g. reduce acceleration -HV Improve vacuum Background count rate [s -1 ] Neutrino-Electron Correlation Coefficient a -0.21-0.19-0.17-0.15-0.13-0.11-0.09 2 3 4 5 6 7 8 9 a =-0.103(4) from PDG2008 Measurements w/o visible proton-like peak Measurements with visible proton-like peak S. Baeßler et al., First measurements with the neutron decay spectrometer aSPECT, Eur. Phys. J. A 38, 17-26 (2008)
8
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 Pulse height spectrum: Beam time at ILL: Principle of extraction of a 470 counts per second at U A = 50 V (one detector pad) Statistical sensitivity on a about 2 % per 24 hours measurement time Background stable Integrated Proton Spectrum: Silicon drift detector at -15kV barrier voltage 50 V 250 V 400 V 500 V 600 V 780 V Count rate [s -1 bin -1 ] 2 4 6 5 0 3 1 Pulse height [ADC channels] 7006004002000 100 300500
9
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 Systematic effects: The magnetic field ratio Correlation coefficient a exp changes with the magnetic field ratio r B, as described by a slightly different response function T U (E) For 0 A: r B = 0.2030; For 50 A: r B ’ = 0.2049 External Helmholtz coils allow us to change magnetic field ratio a =-0.103(4) from PDG2008 F tr (E) with r B = 0.2030 F tr (E) with r B ‘ = 0.2049 F tr (E) with r B = 0.2030 preliminary Helmholtz coils off Helmholtz coils on -0.12 -0.10 -0.08 Uncorrected neutrino electron correlation coefficient a exp Helmholtz coils on Each data point corresponds to about 12 hours of measurement time.
10
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 Summary and Outlook Summary a SPECT extracts a from the measured integrated proton spectrum in free neutron decay Statistical accuracy about 2 % per 24 hours measurement time Studied several systematic effects Total accuracy expected to be well below the present literature value of 5 % Data analysis is currently on the way Outlook Further planned improvements to perform a 0.3 % measurement Online monitoring of the magnetic field ratio (NMR) Investigations of the work function of the electrodes (Kelvin probe)
11
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 Cabibbo-Kobayashi-Maskawa-Matrix Unitarity Condition B/D mesons Superallowed Fermi Decays Neutron Decay n → p + e - + ν e Pion Decay Kaon (Ke3) Decays K → e + π + ν e Kaon (Kμ2) Decays K → μ + ν μ Hyperons The Unitarity of the CKM Matrix
12
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 Test run at FRM-II: Proton Spectra Count rate [s -1 bin -1 ] Pulse height [ADC channels] 100806040200 2 4 6 8 10 12 14 16 18 Protons Electronic noise 0 barrier voltage 50 V 400 V 800 V Proton spectrum looks ok, Count rate: ~250 Hz Signal to background ratio: > 10 : 1 Fundamental requirements: Background stable in time Background independent of the Analyzing Plane Voltage But … Pulse height spectrum
13
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 Test run at FRM-II: Background Instabilities and Dependency on the AP Voltage Electronic noise not stable in time Proton-like peak leads to systematic changes in the proton count rate ⇒ additional systematic uncertainty; does limit our accuracy Count rate [s -1 bin -1 ] Pulse height [ADC channels] 100806040200 2 4 6 8 10 12 14 16 18 Protons Electronic noise 0 barrier voltage 50 V 400 V 800 V usually 800 V sometimes Proton-like peak Pulse height spectrumMeasurement without neutron beam One component of the background rate does depend on the Analyzing Plane Voltage 0 1 2 3 4 5 0200400600800 Analyzing Plane Voltage U A [V] Background count rate [s -1 ]
14
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 new detector -HV electrodeSAES gettersnew ExB electrode Optimization of the spectrometer New detector with better resolution Avoid fluctuating background due to trapped particles Re-design of electrodes + better surface conditions Reduce acceleration -HV Improve vacuum
15
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 15 Beam time at ILL: The proton detector Type: Silicon Drift Detector (SDD) Principle: p-doped backside p-doped rings Potential Valley e - drift to a small anode in the middle P. Lechner et. al., XRS 2004 33 256-261 G. Lutz, Semiconductor Radiation Detectors
16
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 16 Pin-Diode vs. Silicon drift detector PIN-diodeSilicon Drift Detector (SDD) 30 kV (Grenoble Spring 2008) (Munich 2005/ 2006)
17
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 Beam time at ILL: Background Stability Additional neutron shutter allows to monitor background and to study systematic effects No visible background dependency on the Analyzing Plane voltage 0 1 2 3 4 5 0200400600800 Beam time at FRM-II, Garching (2006) Beam time at ILL, Grenoble (Spring 2008) Measurements without neutron beam Analyzing Plane Voltage U A [V] Background count rate [s -1 ]
18
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 Investigations of systematic effects Adiabatic transmission function Different magnetic field settings Measurement of the magnetic field at the beam position, before and after the beam time Different electric field settings Background Additional neutron shutter Different trap cleaner and beam shifter ExB settings Edge effect Different neutron beam profiles Monte Carlo simulations are currectly on the way Detector efficiency Different trigger settings Different post-acceleration voltages Tests at a proton source + SRIM calculations are currently on the way
19
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 Further on-going improvements On-line monitoring of the magnetic field ratio; NMR Study of surface potential; Kelvin probe In collaboration with Prof. I. Baikie, KP Technologies preliminary ע = γ He-3 B 0 γ He-3 ≈ 32.436 [MHz/T]
20
G. Konrad, University of MainzThe a SPECT Experiment, PANIC0810 November ‘08 Material 1Material 2 Kelvin Probe: Tool to measure Work Function _ _ _ + + + V Bias = -V C + Φ1Φ1 E F,1 V Φ2Φ2 E F,2 Φ1Φ1 Φ2Φ2 Φ1Φ1 Φ2Φ2 E F,1 E F,2 E F,1 Material 1 Material 2 Material 1 Material 2 2 Materials with different work functions, isolated 1 st material: to be tested 2 nd material: tip with known work function Electrical Connection: → Charging, until Fermi levels are equal → External electric field → If Material 2 is moved: Capacitance changes, Measurable Current Bias Voltage: → Charge disappears, no external electric field → No current if Material 2 is moved VCVC
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.