Download presentation
Presentation is loading. Please wait.
Published byFrederick Campbell Modified over 8 years ago
1
Aerogel Čerenkov Requirements for the SHMS ( e,e’K + ) Program Hall C User’s Workshop, August 7, 2009. Garth Huber
2
Dr. Garth Huber, Dept. of Physics, Univ. of Regina, Regina, SK S4S0A2, Canada. 2 SHMS (e,e’K + ) Program So far, three SHMS experiments require good K + identification: Experiment Physics Motivation SHMS Momenta (GeV/c) Worst Fore/Bkd Rate Ratio Color Transparency (E12-06-107) vanishing of h-N interaction at high Q.vanishing of h-N interaction at high Q. exclusive π, K production from nuclei.exclusive π, K production from nuclei.5.1-9.61(K):10(p) SIDIS p T (E12-09-017) extract mean k T of u,d,s quarks in proton.extract mean k T of u,d,s quarks in proton. SIDIS π ±, K ± production.SIDIS π ±, K ± production.1.5-5.0 K Factorization (E12-09-011) study of soft-hard factorization in exclusive K + production.study of soft-hard factorization in exclusive K + production. L/T separations vs. Q 2, t.L/T separations vs. Q 2, t.2.6-7.11(K):3(p)
3
Dr. Garth Huber, Dept. of Physics, Univ. of Regina, Regina, SK S4S0A2, Canada. 3 p(e,e’K + ) Missing Mass Resolution Simulation at Q 2 =2.0 GeV 2, W=3.0 and high ε. Example from K + Factorization Proposal.Example from K + Factorization Proposal. SHMS+HMS missing mass resolution (~30 MeV) clearly sufficient to separate Λ and Σ° final statesSHMS+HMS missing mass resolution (~30 MeV) clearly sufficient to separate Λ and Σ° final states Good π + /K + (p/K + ) separation using heavy gas (aerogel) Cerenkov is absolutely required.Good π + /K + (p/K + ) separation using heavy gas (aerogel) Cerenkov is absolutely required. Λ Σ° p(e,e’K+)Λ(Σ°) SHMS+HMS
4
Dr. Garth Huber, Dept. of Physics, Univ. of Regina, Regina, SK S4S0A2, Canada. 4 non-TOF Particle ID @ 1-11 GeV/c Heavy Gas Č erenkov Aerogel Č erenkov TOF * Diagram from SHMS CDR Note: n=1.02,1.015 leads to poor K/p separation at higher momenta.
5
Dr. Garth Huber, Dept. of Physics, Univ. of Regina, Regina, SK S4S0A2, Canada. 5 Aerogel Indices of Refraction (n) K/p separation progressively more difficult at higher momenta.K/p separation progressively more difficult at higher momenta. To maintain reliable K/p separation over a wide momentum range aerogels with variety of n are required.To maintain reliable K/p separation over a wide momentum range aerogels with variety of n are required. p SHMS (GeV/c) n (10cm) K N pe p N pe 2.5-3.01.03013-46<0.5 3.1-3.71.02012-31<0.5 3.8-4.31.01513-24<0.5 4.4-5.11.0105.5-<0.5 5.2-6.21.00755.5-13<1 6.4-7.31.00556-9<1 Calculation assumes good PMT spectral response, 75% light collection efficiency.
6
Dr. Garth Huber, Dept. of Physics, Univ. of Regina, Regina, SK S4S0A2, Canada. 6 S1 Hodoscope Space Reserved for 1-2 Aerogel Č erenkovs SHMS Detector Stack Drift Chambers C 4 F 8 O Č erenkov S2 Hodoscope Ar/Ne Č erenkov Calorimeter
7
Dr. Garth Huber, Dept. of Physics, Univ. of Regina, Regina, SK S4S0A2, Canada. 7 Aerogel Č erenkov Design Considerations Requirements: Easy and fast exchange of Aerogel tray is essential.Easy and fast exchange of Aerogel tray is essential. Although only one Aerogel Čerenkov is required at any P SHMS,Although only one Aerogel Čerenkov is required at any P SHMS, two detectors would reduce accesses to swap Aerogel when changing momentum. Detector must be slender.Detector must be slender. HMS Aerogel is 25cm thick.HMS Aerogel is 25cm thick. Minimum active area: 110x130cm 2.Minimum active area: 110x130cm 2. Compare to 70x120cm 2 for HMS.Compare to 70x120cm 2 for HMS. Division into optically isolated segments could enhance high rate capability.Division into optically isolated segments could enhance high rate capability. HMS Aerogel Č erenkov ISO View
8
Dr. Garth Huber, Dept. of Physics, Univ. of Regina, Regina, SK S4S0A2, Canada. 8 HMS Aerogel Č erenkov Performance Baseline of 0.6 photoelectrons for sub-threshold particles.Baseline of 0.6 photoelectrons for sub-threshold particles. π detection efficiency in n=1.030 aerogel >99% with N pe >4 cut applied.π detection efficiency in n=1.030 aerogel >99% with N pe >4 cut applied. Variation in total light detected varies by up to 20% across focal plane due to varying path of light through aerogel to PMT and other factors.Variation in total light detected varies by up to 20% across focal plane due to varying path of light through aerogel to PMT and other factors. R. Asaturyan, et al., NIM A548 (2005) 364.
9
Dr. Garth Huber, Dept. of Physics, Univ. of Regina, Regina, SK S4S0A2, Canada. 9 Summary Currently, there are three approved SHMS experiments requiring K + identification.Currently, there are three approved SHMS experiments requiring K + identification. –Anticipate more experiments with this requirement in future. Threshold Aerogel Čerenkov detector is simplest and most economical way to satisfy K/p separation requirement.Threshold Aerogel Čerenkov detector is simplest and most economical way to satisfy K/p separation requirement. – ~6 sets of aerogel with different n would enable excellent K/p separation over a wide momentum range. –Also helpful to supplement π ± identification below 3.4 GeV/c. Design considerations: Design considerations: – Helpful if aerogel tray can be changed relatively easily. – Very attractive to have 2 Aerogel Čerenkovs in detector stack. Need to watch space requirements very carefully!Need to watch space requirements very carefully! – SHMS beam envelope more square than HMS. Need to avoid efficiency drop in center of detector.Need to avoid efficiency drop in center of detector.
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.