1 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 1 AdvancedTCA Systems Platforms according to PICMG 3.0 for SRS Systems Presentation to Collaboration Meeting WG6 23.11.2011 CERN

2 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 2 Table of Contents 2U ATCA Systems Platforms CAP002002 CAP002021 CAP002034 5U ATCA Systems Platforms CAP001476 13U ATCA Systems Platforms CAP002014

3 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 3 3 ATCA Platforms

4 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 4 4 II Generation Backplane Design ready for 40GB/s

5 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 5 II Generation ATCA Platforms 5U, 5 slot AC 2U, 2 slot DC 13U, 14 slot DC 5U, 6 slot DC 5

6 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 6 ATCA II GEN 2U 2 slot DC Features 2U high Holds 2 ATCA cards 2 slot Full mesh backplane Rear I/O Dual Shelf Managers Dual removable fan trays 250 watts/slot cooling Dual 48VDC input NEBS compliant removable air filter 6

7 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 7 ATCA Systems Platform 2U, CAP002002 2 slot with RTM, 1 Shelf Manager fix mount, 2 Fan Trays pluggable with 3 Fans each, Air Filter, 1 PSU 115VAC / 250W fix mount Front View

8 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 8 ATCA Systems Platform 2U, CAP002002 2 slot with RTM, 1 Shelf Manager fix mount, 2 Fan Trays pluggable with 3 Fans each, Air Filter, 1 PSU 115VAC / 250W fix mount Rear View

9 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 9 ATCA Systems Platform 2U, CAP002034 2 slot with RTM, 1 Shelf Manager fix mount, 2 Fan trays pluggable with 3 Fans each, Air Filter, Dual, redundant -48VDC Feeds Front View

10 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 10 ATCA Systems Platform 2U, CAP002034 2 slot with RTM, 1 Shelf Manager fix mount, 2 Fan trays pluggable with 3 Fans each, Air Filter, Dual, redundant -48VDC Feeds Rear View

11 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 11 ATCA II GEN 5U 5 slot AC Features 5U high Holds 5 ATCA cards 5 slot triple mesh backplane RTM (with cooling) Dual Shelf Managers Dual removable fan trays 250 watts/slot cooling 1200 Watt, AC input PSU (N+1 optional) NEBS compliant removable air filter 11

12 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 12 ATCA II GEN 5U 6 slot DC Features 5U high Holds 6 ATCA cards 6 slot Full mesh backplane RTM (with cooling) Dual Shelf Managers Dual removable fan trays 250 watts/slot cooling Dual 48VDC input NEBS compliant removable air filter 12

13 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 13 ATCA II GEN 5U 6 slot DC Features 6U high Holds 6 ATCA cards 6 slot Full mesh backplane RTM (with cooling) Dual Shelf Managers Dual removable fan trays 250 watts/slot cooling 1200 Watt, AC input PSU (N+1 optional) NEBS compliant removable air filter 13

14 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 14 ATCA Systems Platform 5U, CAP001476 5 slot with RTM, 1 Shelf Manager fix mount, 1 Fan tray pluggable with 2 Fans, Air Filter, 1 PSU 90-264VAC / 600W, N+1, fix mount Front View

15 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 15 ATCA Systems Platform 5U, CAP001476 5 slot with RTM, 1 Shelf Manager fix mount, 1 Fan tray pluggable with 2 Fans, Air Filter, 1 PSU 90-264VAC / 600W, N+1, fix mount Rear View

16 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 16 Dual Shelf Manager Push Pull Fan Configuration Filter Tray removable from the Front Dual 48V input Easy Conversion to AC Version Carrying Handles for Lab transportation 5U ATCA with Rear I/O DCA0

17 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 17 Easy removable Fan Tray left and right. No Tools required. Right Fan Tray with integrated Filter. Left side 8 Fans 80mm al the way to the back for rear I/O cooling. Right fan tray 6 Fans 80mm.

18 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 18 Filter Tray extended to cover Rear I/O Area. Removable from the Front. No Tools required. Filter Mesh washable fixed with Velcro to the Filter tray. Fan Tray stays in Place.

19 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 19 Two Shelf manager installed on Top of Card cage. Easy Removable from the Front trough the convenient ELMA Hot Swap Handle.

20 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 20 ON/OFF Switch located above left Fan Tray, for easy Start or shut down. ESD Jack located in Front for easy plug in. Marked with Yellow Plate to get attention.

21 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 21 For Easy Transportation additional Carrying Handle on each Side. Integrated to stay in the 19 Inch Width.

22 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 22 AC-Version DC-Version DC Version with two Filtered Terminal Blocks including Safety cover. DC Hole Arrangement cover with Patch-Panel. ESD Jack on the left Top for easy Access. Marked with Yellow Silkscreen Plate to get Attention. Grounding Feature with Bridge to connect Logic Ground to Chassis Ground if needed.

23 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 23 Height: 5U 221.4mm Width Front:19”482.6mm Width Rear:17.5”444.5mm Depth:16.5”419.1mm Overall Depth Flange to Terminal Block 17”431.8mm

24 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 24 ATCA II Gen 13U 14 slot DC Features 13U high Holds 14 ATCA cards 14 slot Dual Star or Full Mesh Backplane RTM (with 40 watts/slot cooling) Dual Shelf Managers Quad Redundant 48VDC input 3 x removable fan trays 300 watts/slot Cooling NEBS compliant removable air filter 24

25 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 25 8 Slot Horizontal Custom 25 Redundant HDD Tray Redundant HDD Trays Quad Redundant 48VDC input 2 x removable fan trays 300 watts/slot Cooling Features 6U high Holds 8 ATCA cards 8 slot Custom Backplane Rear I/O

26 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 26 The injector and ejector handle stands out with its ergonomic design. It guarantees the proper release and locking of the plug-in unit, confirming this with a clearly audible and positive click. Pre-assembled Self-locking screws for front panel and board mounting Plastic parts black (UL 94 V-0) Base part including alignment pin Retaining screw pre-assembled ATCA Board Level Components

27 Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 27 Thank you for your attention.


Download ppt "Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets 10.11.2011Friedrich Fix 1 AdvancedTCA Systems Platforms according to PICMG."

Similar presentations


Ads by Google