Module Bench Tests CMS Pixel Upgrade Workshop, Aug, 2012 University of Puerto Rico – Mayaguez Alejandro Carlo Joseph Cordero Angel López University of Kansas Gemma Tinti Alice Bean University of Nebraska José Lazo-Flores Paul Scherrer Institute Wolfram Erdmann
2
Two projects Thermal Paste Performance Analog Current, Threshold and Risetime Changes with Temperature Module Bench Tests2 CMS Pixel Upgrade Workshop, Aug, 2012
3
Module Bench Tests3 CMS Pixel Upgrade Workshop, Aug, 2012
4
Thermal Test Setup CMS Pixel Upgrade Workshop, Aug, 2012 Module Bench Tests4 Thermal Paste Carbon Fiber Support
5
Module Bench Tests5 CMS Pixel Upgrade Workshop, Aug, 2012
6
4 wire Resistance Measurement Module Bench Tests6 CMS Pixel Upgrade Workshop, Aug, 2012
7
RTD Calibration Module Bench Tests7 CMS Pixel Upgrade Workshop, Aug, 2012
8
Leakage Current vs Temperature Module Bench Tests8 CMS Pixel Upgrade Workshop, Aug, 2012 8Bias Voltage = 80 V
9
Seven Temperatures Cold box RTD – kept at 10 C. One RTD on the carbon fiber support Three RTDs along base strip One RTD attached to top of module Module temperature determined from leakage current Module Bench Tests9 CMS Pixel Upgrade Workshop, Aug, 2012
10
Module Bench Tests10 Temperature vs Power Without Thermal Grease CMS Pixel Upgrade Workshop, Aug, 2012
11
Module Bench Tests11 Temperature vs Power With Thermal Paste CMS Pixel Upgrade Workshop, Aug, 2012
12
Module Test Setup at PSI Module Bench Tests12 CMS Pixel Upgrade Workshop, Aug, 2012
13
Module Bench Tests13 CMS Pixel Upgrade Workshop, Aug, 2012
14
Module Bench Tests14 CMS Pixel Upgrade Workshop, Aug, 2012
15
Risetime Constant vs Temperature for I ana = 24 mA Module Bench Tests15 CMS Pixel Upgrade Workshop, Aug, 2012
16
Faster Risetime with Larger I ana Module Bench Tests16 CMS Pixel Upgrade Workshop, Aug, 2012
17
Conclusions Thermal paste very effective in reducing sensor temperature. Threshold and risetime do not change with temperature if V ana is adjusted to control I ana. If V ana is kept constant, I ana and threshold rise linearly with temperature while the risetime is reduced. Module Bench Tests17 CMS Pixel Upgrade Workshop, Aug, 2012