Download presentation
Presentation is loading. Please wait.
Published byBrandon Chandler Modified over 8 years ago
1
- TMS - Temperature Monitoring System in Topix Olave Jonhatan INFN section of Turin and Politecnico P PANDA Collaboration Meeting December 9 th 2014 - Forschungszentrum Jülich
2
Jülich, December 2014J. Olave - INFN -2 Outline Motivation Requirements The circuit Architecture Simulation results Conclusion and Outlook Motivation Requirements Architecture Simulations Conclusion Outlook
3
Jülich, December 2014J. Olave - INFN -3 Motivation Requirements Architecture Simulations Conclusion Outlook Test Board for Topix 4
4
Jülich, December 2014J. Olave - INFN -4 Motivation Requirements Architecture Simulations Conclusion Outlook Test Board for Topix 4 Topix 4 Sensor LM95071
5
Jülich, December 2014J. Olave - INFN -5 Motivation Test Board for Topix 4 Topix 4 Sensor LM95071 Layout of Topix 4 Motivation Requirements Architecture Simulations Conclusion Outlook
6
Jülich, December 2014J. Olave - INFN -6 Requirements Motivation Requirements Architecture Simulations Conclusion Outlook Voltage supply of 1.2 V CMOS 0.13 um technology Reduced silicon area Working range from 0° C to 100° C Low power consumption Clock frequency 160 MHz Good resolution (± 0.1°C) Calibration system Radiation hardness Digital output BASIC REQUIREMENTS ASIC REQUIREMENTS
7
Jülich, December 2014J. Olave - INFN -7 The Circuit Architecture Motivation Requirements Architecture Simulations Conclusion Outlook
8
Jülich, December 2014J. Olave - INFN -8 Basic idea to design a BandGap Reference (GBR) V1 = V1(T) ΔV1/ ΔT = α1 T + β1 T 2 + …. V2 = V2(T) ΔV2/ ΔT = α2 T + β2 T 2 + …. V REF (T) = k 1 V1(T) + k 2 V2 (T) It is possible to choose k1 and k2 in order to have ΔV REF / ΔT = 0 The T sensor Motivation Requirements Architecture Simulations Conclusion Outlook
9
Jülich, December 2014J. Olave - INFN -9 The T sensor Basic idea BandGap Reference (GBR) V1 = V1(T) ΔV1/ ΔT = α1 T + β1 T 2 + …. V2 = V2(T) ΔV2/ ΔT = α2 T + β2 T 2 + …. Motivation Requirements Architecture Simulations Conclusion Outlook V REF (T) = k 1 V1(T) + k 2 V2 (T) It is possible to choose k1 and k2 in order to have ΔV REF / ΔT = 0
10
Jülich, December 2014J. Olave - INFN -10 NTC The T sensor Motivation Requirements Architecture Simulations Conclusion Outlook
11
Jülich, December 2014J. Olave - INFN -11 Bandgap Analog to Digital Converter Vt Vref Motivation Requirements Architecture Simulations Conclusion Outlook FIRST STEPS time Voltage [V] 1.2 Vt @ constant T Signal generator Digital Output
12
Jülich, December 2014J. Olave - INFN -12 Bandgap Analog to Digital Converter Vt Vref Digital Output Motivation Requirements Architecture Simulations Conclusion Outlook time Voltage [V] 1.2 Vt @ constant T Ramp Generator Signal generator Vramp information Comparator FIRST STEPS
13
Jülich, December 2014J. Olave - INFN -13 Bandgap Analog to Digital Converter Vt Vref Digital Output Motivation Requirements Architecture Simulations Conclusion Outlook time Voltage [V] 1.2 Vt @ constant T Ramp Generator Signal generator Vramp information MUXMUX Comparator FIRST STEPS
14
Jülich, December 2014J. Olave - INFN -14 Bandgap Analog to Digital Converter Vt Vref Digital Output Motivation Requirements Architecture Simulations Conclusion Outlook time Voltage [V] 1.2 Vt @ constant T Ramp Generator Signal generator Vramp information Counter Register A MUXMUX Register B Adder Devider Adder Offset Comparator FIRST STEPS
15
Jülich, December 2014J. Olave - INFN -15 Bandgap Analog to Digital Converter Vt Vref Digital Output Motivation Requirements Architecture Simulations Conclusion Outlook time Voltage [V] 1.2 Vt @ constant T Ramp Generator Signal generator Vramp information Counter Register A Control Unit MUXMUX Register B Adder Devider Adder Offset Comparator FIRST STEPS
16
Jülich, December 2014J. Olave - INFN -16 Bandgap Analog to Digital Converter Vt Vref Digital Output Motivation Requirements Architecture Simulations Conclusion Outlook time Voltage [V] 1.2 Vt @ constant T Ramp Generator Signal generator Vramp information Counter Register A Control Unit MUXMUX Register B Adder Devider Adder Offset Comparator FIRST STEPS
17
Jülich, December 2014J. Olave - INFN -17 Bandgap Analog to Digital Converter Vt Vref Digital Output Motivation Requirements Architecture Simulations Conclusion Outlook time Voltage [V] 1.2 Vt @ constant T Ramp Generator Signal generator Vramp information Counter Register A Control Unit MUXMUX Register B Adder Devider Adder Offset Comparator FIRST STEPS Vramp Analog Environment Digital Environment
18
Jülich, December 2014J. Olave - INFN -18 Motivation Requirements Architecture Simulations Conclusion Outlook FIRST STEPS Layout View (100 um x 100 um) Schematic View
19
Jülich, December 2014J. Olave - INFN -19 Motivation Requirements Architecture Simulations Conclusion Outlook Simulation results
20
Jülich, December 2014J. Olave - INFN -20 Variation of the supply voltage - ΔV ref / ΔV supply ≈ 1.4 mV/V - ΔV t / ΔV supply ≈ 1.4 mV/V Variation with the temperature - ΔV ref / ΔT ≈ 10 -2 mV/°C - ΔV T / ΔT ≈ - 1.63 mV/°C ( IMPROVE ) BANDGAP AND SIGNAL GENERATOR Motivation Requirements Architecture Simulations Conclusion Outlook
21
Jülich, December 2014J. Olave - INFN -21 Variation of the supply voltage - ΔV ref / ΔV supply ≈ 1.4 mV/V - ΔV t / ΔV supply ≈ 1.4 mV/V Variation with the temperature - ΔV ref / ΔT ≈ 10 -2 mV/°C - ΔV T / ΔT ≈ - 1.63 mV/°C ( IMPROVE ) BANDGAP AND SIGNAL GENERATOR SIGNAL AMPLIFICATION Two stage op amp with single ended output Good linearity of V T * ΔV T / ΔT ≈ + 7.3 mV/°C Motivation Requirements Architecture Simulations Conclusion Outlook
22
Jülich, December 2014J. Olave - INFN -22 Motivation Requirements Architecture Simulations Conclusion Outlook RAMP GENERATOR
23
Jülich, December 2014J. Olave - INFN -23 Motivation Requirements Architecture Simulations Conclusion Outlook RAMP GENERATOR
24
Jülich, December 2014J. Olave - INFN -24 ΔV ramp /Δt ≈ 136 mV/us Good control of the initial value (250 mV) The time to discharge the capacitor is ≈ 30 ns Motivation Requirements Architecture Simulations Conclusion Outlook RAMP GENERATOR
25
Jülich, December 2014J. Olave - INFN -25 ΔV ramp /Δt ≈ 136 mV/us Good control of the initial value (250 mV) The time to discharge the capacitor is ≈ 30 ns COMPARATOR Two stages folded cascode structure 2 CMOS inverters offset = 5 mV supply current = 3.5 uA Motivation Requirements Architecture Simulations Conclusion Outlook RAMP GENERATOR
26
Jülich, December 2014J. Olave - INFN -26 Motivation Requirements Architecture Simulations Conclusion Outlook DIGITAL PART Post PnR simulation
27
Jülich, December 2014J. Olave - INFN -27 Motivation Requirements Architecture Simulations Conclusion Outlook CONCLUSION The system is able to extract the information as expected Single analog and digital blocks tested with good results The Digital layout is done and tested with good results
28
Jülich, December 2014J. Olave - INFN -28 Motivation Requirements Architecture Simulations Conclusion Outlook CONCLUSION OUTLOOK Conclude the AMS simulations Use SEU protections for the digital part Reduce the silicon area used for the digital part Start with the analog layout to perform more realistic simulations The system is able to extract the information as expected Single analog and digital blocks tested with good results The Digital layout is done and tested with good results
29
Jülich, December 2014J. Olave - INFN -29 THANK YOU FOR YOUR ATTENTION
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.