Download presentation
Presentation is loading. Please wait.
Published byAlban Owens Modified over 8 years ago
1
Studený P., Dědková B., Farkaš A., Vokrojová M., Siveková D., Břešťák M. Oční klinika FNKV a 3 LF UK Praha Oční oddělení, Karlovarská krajská nemocnice a.s. Centrum Fetální medicíny Praha Accommodation measurement in eyes implanted with Tek-Clear Accommodative Intraocular Lens Tek-Clear Accommodative IOL is manufactured by: TEKIA, INC. www.tekia.com
2
Multifocal IOL Refractive/diffractive Accommodating IOL Predictability: far vision ++ intermediate vision + -+ near vision + + - Disphotopic phenomena +- Contrast sensitivity -0 Stability of refraction + + - Ways to restore accommodative ability after cataract surgery
3
Disc-shaped; excellent stability and centration in capsular bag 5.5 mm optic, 10.4 or 10.2 mm haptic Biconvex shape Hydrophilic acrylic A-constant 118.0 Thin junctions between optic and haptic part ; lens movement optimization during accommodation (pseudophakic accommodation) Square-edge design to minimize PCO Tek-Clear Accommodative IOL
4
Number of patients: n=18 (32 eyes) Average age of patients: 60.6 (28-81) Follow up time: 3 months at least Preoperative UCVA: 0.28 (0.05- 0.7) Preoperative BCVA: 0.65 (0.05-1.0) Preoperative refraction (SE): 2.125 (0-6) Cataract Examination objectives: UCVA, BCVA, accommodative amplitude Patients, materials and methods
5
1 phaco surgeon Standard cataract surgery, CCI 2.2mm, incision u.12, Infinity vision system, bimanual I/A, PCIOL implantation without OVD Patients, materials and methods
7
IOL movement in eye
8
Ultrasound system Vivid7Pro, Probe L12M
9
Ultrasound examination
10
Push-up test Defocus Plusoptix Eye accommodation examination
11
Subjective method Optimal correction for long distance Text is moved towards the patient – he/she notifies when the text becomes blurred Push-up test – results
12
After 7 days 3.92 D (1-5) After 1 month 3.52 D (1-5) After 3 months 4.17 D (1-5) Push-up test – results
14
Subjective method Optimal correction for long distance Patient watches optotypes placed 5m in front of him Minus lens correction is progressively increased until the image become blurred Defocus method
15
After 7 days – 0.79D (- 0.5D -1.25D) After 1 month – 0.85D ( -0.5D – 1.25D) After 3 months – 0.87D ( -0.5D – 1.5D) Defocus method – results
16
Objective method Binocular auto-refractometer is placed 1 meter in front of the patient Fixation target is moved towards the patient Changes in eye refraction are recorded – refraction difference between short and long distance Plusoptix
17
After 7 days – 1.92D ( 0.88 – 3.04) After 1 month – 2.16D ( 0.89 – 4.18) After 3 months – 2.2D (1.0 – 3.6) Plusoptix – results
19
Excellent accommodation ability of Tek-clear IOL was demonstrated by means of subjective and objective examination of accommodation amplitude at 3 months follow up. Anterior optic vault during accommodation was captured using high-frequency ultrasound – this effect explains increase in optical power of lens Summary
20
Longer follow up time is needed More patients Summary
21
Thank you for your attention
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.