Lone Star Transmission Presentation on SSR Blair Giffin Operations Engineer September 9, 2013
2
2 History of Lone Star and CREZ Lone Star Transmission System Sub-Synchronous Resonance (SSR) Mitigating the effects SSR Lone Star Transmission Coordination & Mitigation Topics
3
3 In 2008 ERCOT performed the CREZ Transmission Optimization Study (CTOS) that included 4 build-out options PUCT selected a 345kV build-out option, including series- compensated lines PUCT selected Lone Star Transmission to build series- compensated West Shackelford to Sam Switch/Navarro (and Scurry County South – West Shackelford) ERCOT commissioned ABB to perform the CREZ Reactive Compensation Study that verified amounts of series compensation and sized additional reactive devices History of Lone Star and CREZ
4
4 Lone Star Transmission 345 kV Circuits With Series Compensation ‒ Navarro – W. Shackelford 345kV Line ‒ Sam Switch – W. Shackelford 345kV Line Without Series Compensation ‒ West Shackelford - Scurry County South 345 kV Line 1 ‒ West Shackelford - Scurry County South 345 kV Line 2 Lone Star Transmission 345 kV Substations West Shackelford Switching Station Kopperl Series Compensation Station Romney Series Compensation Station Navarro Switching Station Sam Switch Switching Station Lone Star Transmission System
5
5 Scurry County South West Shackelford Kopperl Series Compensation Station Clear Crossing Romney Series Compensation Station Ties to Existing Grid Sam Switch Navarro Ties to Existing Grid Lone Star Transmission System
6
6 Fort Worth – Dallas Abilene
7
7 SSR is an interaction between series capacitors and torsional frequencies of turbine-generator rotors SSR was studied in 1937 when The General Electric Company noticed oscillations in distribution systems with series capacitors 1970 – Mohave generating plant in Nevada experienced turbine-generator interaction To date, numerous series-compensated transmission systems have been designed, installed and safely operated Sub-Synchronous Resonance (SSR)
8
8 Several proven methods exist for mitigating the effects of SSR* (some methods do not apply to every capacitor type) Switching of series capacitors (by-passing) or limiting the total amount of compensation SSR blocking filters Supplemental exciter damping controls (SEDC) Thyristor-controlled series capacitor (TCSC) Dynamic stabilizer at generator * IEEE P1726™/D10 Draft Guide for the Specification of Fixed Series Capacitor Banks for Transmission System Applications Mitigating the Effects of SSR
9
9 Lone Star Transmission is working with ERCOT and Transmission Owners –SSR Studies –Outage Coordination to reduce potential SSR –Operational mitigation plans Lone Star Transmission has: –Developed situational awareness tools that identify ERCOT transmission conditions (line outages) that increase the potential for SSR –Implemented switching procedures to by-pass series capacitors, mitigating the potential for SSR Lone Star Transmission Coordination & Mitigation
10
10 Questions? Thank you