Download presentation
Presentation is loading. Please wait.
Published byWillis Tate Modified over 8 years ago
1
RACT 2 – Source Testing and Monitoring Requirements Air Quality Technical Advisory Committee August 4, 2016 Harrisburg, PA Tom Wolf, GovernorPatrick McDonnell, Acting Secretary 1
2
On April 23, 2016, the Environmental Quality Board (EQB) promulgated additional reasonably available control technology (RACT 2) requirements for major stationary sources of nitrogen oxides (NOx) and volatile organic compounds (VOCs). An owner or operator must demonstrate compliance with the RACT 2 regulation by January 1, 2017. An owner or operator of air contamination sources with continuous emission monitoring systems (CEMS) must use them to demonstrate compliance. Background 2
3
Existing emission and data availability standards remain in place. An owner or operator of an air contamination source without CEMS must conduct source testing to demonstrate compliance. Background 3
4
For an air contamination source with CEMS, compliance will be demonstrated with a 30 operating day rolling average emission rate (except municipal waste combustors that will comply using a daily average). An operating day is defined as a 24-hour period beginning at 12:00 midnight during which the source operates at any time and produces emissions. It includes emissions that were generated during startups, shutdowns, or malfunctions. 30 Operating Day Rolling Average Emission Rate 4
5
Hourly data validation will be conducted as per the data reduction criteria contained in Revision No. 8 of the Department’s Continuous Source Monitoring Manual (Manual). Data substitution is required for invalid hours in which monitoring is required. Data availability criteria will apply for hours in which monitoring is required. 30 Operating Day Rolling Average Emission Rate 5
6
The 30 operating day rolling average emission rate will be calculated as follows: A.Sum the total pounds of pollutant emitted from the combustion unit for the current operating day and the previous 29 operating days. B.Sum the total heat input to the combustion unit in million Btu (MBtu) for the current operating day and the previous 29 operating days. C.Divide A (above) by B (above) to determine the emissions rate (lbs/MBtu). 30 Operating Day Rolling Average Emission Rate 6
7
An owner or operator of an air contamination source with CEMS will submit a monitoring plan (MP) in the Department’s CEM Data Processing System (CEMDPS). Each major source category requires slightly different content to be included in the MP. Monitoring Plan 7
8
For a combustion unit or process heater, include the following in the MP: – A new emission result and CEMS for hourly mass emissions (lbs), hourly heat input (MBtu), and hourly (lbs/MBtu). – A new emission result and CEMS for allowable hourly emission rate (lbs/MBtu) for those that have a variable emission standard. – Each CEMS should be associated with the appropriate analyzer(s). Monitoring Plan 8
9
For a combustion turbine, include the following in the MP: – A new emission result and CEMS for hourly concentration emissions (PPM @ 15% O2). – A new emission result and CEMS for allowable hourly emission rate (PPM @ 15% O2) and hourly heat input (MBtu) for those that have a variable emission standard. – Each CEMS should be associated with the appropriate analyzer(s). Monitoring Plan 9
10
For a Portland cement kiln, include the following in the MP: – A new emission result and CEMS for hourly mass emissions (lbs), hourly clinker production (tons), and hourly (lbs/ton-clinker). – Each CEMS should be associated with the appropriate analyzer(s). Monitoring Plan 10
11
For a municipal waste combustor, only submit a monitoring plan if a new daily average NOx emission standard must be added. Monitoring Plan 11
12
An owner or operator of an air contamination source with CEMS will submit a certification test protocol and certification test report in the CEMDPS once the MP has been approved. A data acquisition and accuracy check must be successfully completed. Sample hours of emissions data (under various scenarios) will be required. An acceptable sample report must be submitted in the CEMDPS for any new emission results. Performance Testing and Certification 12
13
Upon Department certification, the owner or operator of an air contamination source with CEMS will submit hourly emissions data to the Department. Data will be required starting with the first quarter of 2017. Quarterly Emission Reports 13
14
For a combustion unit or process heater, submit hourly mass emissions (lbs) and hourly heat input (MBtu). The owner or operator will also submit the allowable hourly emission rate (lbs/MBtu) for sources that have a variable emission standard. – Department software will calculate a 30 operating day rolling average emission rate (lbs/MBtu) for each operating day. The software will also calculate the allowable for sources that have a variable emission standard. Quarterly Emission Reports 14
15
For a combustion turbine, submit the hourly concentration (PPM @ 15% O2). The owner or operator will also submit the allowable hourly concentration (PPM @ 15% O2) and hourly heat input (MBtu) for sources that have a variable emission standard. – Department software will calculate a 30 operating day rolling average emission rate (lbs/MBtu) for each operating day. The software will also calculate the allowable for sources that have a variable emission standard. Quarterly Emission Reports 15
16
For a Portland cement kiln, submit hourly mass emissions (lbs) and hourly clinker production (tons). – Department software will calculate a 30 operating day rolling average emission rate (lbs/ton-clinker) for each operating day. For municipal waste combustors, submit average hourly concentration emissions (PPM @ 7% O2). Quarterly Emission Reports 16
17
The emission limit shall be determined on a total heat input fuel weighted basis using the equation in RACT 2. A fuel representing < 1% of the unit’s annual fuel consumption on a heat input basis is excluded when determining the emission limit. The owner or operator of the unit must demonstrate that this exclusion applies over a 12-calendar month period, rolling by 1-month. – For example, the exclusion would exist for the month of July if the fuel met this criteria from August of the preceding year to July of the current year. Units Firing Multiple Fuels 17
18
Corroborating information should be included in the cover letter of the quarterly emissions report if the exclusion is utilized. The owner or operator of a unit may petition the Department to include a fuel representing < 1% of the unit’s annual fuel consumption on a heat input basis in the emission limit. Units Firing Multiple Fuels 18
19
You may use the CEMDPS to demonstrate compliance on a facility-wide basis if the following criteria are met: – All underlying emission results, CEMS, and analyzers conform to the requirements of the Manual. – The Department may approve the use of analyzers that have been “certified” under an applicable Federal program. Additional testing may be required. Those not meeting the above must submit a quarterly compliance report to the applicable DEP Regional Office to demonstrate compliance. Emissions Averaging Plans 19
20
All demonstrations of compliance on a system-wide basis should be submitted as a quarterly compliance report to the applicable DEP Regional Office. If more than one DEP Region is involved, a copy of the report must be submitted to each. Emissions Averaging Plans 20
21
Monitoring and testing must be conducted in accordance with a Department approved emissions source test that meets the requirements of Chapter 139, Subchapter A (relating to sampling and testing methods and procedures). Source testing must be conducted one time in each 5-year calendar period. Source Testing Requirements 21
22
The owner or operator of a unit may reference a previously approved test protocol (i.e. no new protocol needed) if the following conditions are met: – They agree to meet all conditions of acceptance of the protocol. – Nothing has changed since Department approval was granted (i.e. same relevant testing requirements, same process operating conditions, same testing subcontractor, etc.). Source Testing Requirements 22
23
Division of Source Testing and Monitoring Program Contact Charles J. Zadakis, Program Manager Department of Environmental Protection Harrisburg, PA 17105-8468 Telephone: (717) 783-9479 czadakis@pa.gov 23
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.