Download presentation
Presentation is loading. Please wait.
Published byLaurence Griffith Modified over 8 years ago
1
SEMINAR REPORT ON SWAGATIKA SAHOO REG NO: 0701291202
2
WHAT IS A CIRCUIT BREAKER? A circuit breaker is an equipment which can: make or break a circuit either manually or automatically under normal conditions break a circuit under abnormal conditions
3
POINTS TO BE DISCUSSED:- PRINCIPLE ARCS CLASSIFICATION SF6 CIRCUIT BREAKER—DETAILS CONCLUSION
4
Fixed contact Moving contact ARC Fixed contact Moving contact ARC ARC IS QUENCHED BY MEDIUM IN A CIRCUIT BREAKER OPERATING PRINCIPLE OF BREAKER
5
OVERVIEW OF ARCS IN BREAKERS-: During the separation of contacts, due to large fault current and high current density at the contact region the surrounding medium ionises and thus a conducting medium is formed. This is called the ARC.
6
PRINCIPLES OF ARC EXTINCTION Factors responsible for arc:- Potential difference between the contacts Ionised particles between the contacts By removing any one of these the arc can be quenched.
8
CLASSIFICTION OF CIRCUIT BREAKERS OILAIR VACCUMSF6 OIL CIRCUIT BREAKER AIR BLAST CIRCUIT BREAKER VACCUM CIRCUIT BREAKER SF6 CIRCUIT BREAKER
9
OVERVIEW OF SF6 GAS:- 1. High dielectric strength 2. Excellent arc quenching ability 3. Excellent thermal stability 4. Good thermal conductivity Electrical properties
10
1. Chemically inert 2. Non-toxic 3. Non-corrosive 4. Non-flammable Physical & Chemical properties 5. High density 6.High electro-negativity
11
Dielectric properties of SF6 gas:- DDS of sf6 is 2.5 times of air DDS of sf6 is 30% less than oil DDS of sf6 is equal to oil at 63700 N/m2 AAnd 15% higher at 122500 N/m2
12
Advantages of SF6 gas:- 1. Increased safety 2. Reduced size 3. Easy installation 4. Low maintenance
13
SF6 CIRCUIT BREAKER OPERATION
14
SF6 DECOMPOSITION PRODUCTS S F6 SF4 + 2F SOF2 + 2HF MF n SO2 + HF SiF4 + 2 H2O SPARK H2O SiO2 M
15
m agnitude & duration of discharge m materials of construction of equipment contamination levels of moisture and air inside the equipment Amount of each decomposition product depends on :-
16
REMOVAL OF SF6 BYPRODUCTS:- Byproducts are corrosive & likely to affect the organic materials. Absorbent materials used in circuit breakers a activated alumina( effective for S OF2,H2S,SF2) m molecular sieves ( sodalime- CaO.NaOH)- removes stable gases such as SF4,SiF4 & S2F2 So suggested mix is 50/50 of sodalime & alumina. The suggested weight of absorbent is 10% of the weight of the gas
17
ADVANTAGES OF SF6 CIRCUIT BREAKERS Very short arcing period Can interrupt much larger currents as compared to other breakers No risk of fire Low maintenance, light foundation, minimum auxiliary equipments No over voltage problem
18
CONCLUSION Harnessing the utilities of SF 6 gas in power system and power system equipments, makes it more reliable and safer to use. The countless advantages this SF 6 gas has to offer will take us to new heights in the prevalent orthodox power system.
19
THANK U ALL FOR A PATIENT HEARING. HOPE I SATISFIED THE CURIOSITY OF THE AUDIENCE. NOW I WELCOME ALL QUERIES FROM MY REPORT.