1 Guide: Prepared by: Ms. DINA ANNA JOHN MITTU SUNNY Lecturer, AEI department S7 AEI

2  Biotelemetric system aimed at monitoring of patient ‘s vital functions.  It consist of two parts- inner part and outer part.  TCP and UDP protocols are used for the communication between these parts  Communication in inner part is implemented using zigbee technology 

3 It consist of two parts a. Inner part It is located at patient’s home. It is used for the acquasition of biotelemetric data b. Outer part It is located at monitoring centre Single instance of outer part can control multiple instance of inner part

4 There are three hardware element  CERBERUS-Mobile data acquiring unit  ORTHRUS -Stationary data forwarding unit  SENSORs -Stationary data acquiring unit

5 It having four elements  CENTREs - endpoints aggregating measured data.  DHCP server- provides IP settings.  NTP server - provides accurate time.  SNMP NMS protocol - management of whole system.

6 Fig 2:Outer part of model biotelemetric system

7  ORTHRUS and CERBERUS are key elements  The components used by them are  ARM7TDMI microcontroller  FRAM memory for caching and temporary storage of data  FPGA for passing raw biometric data  ZigBee controller for controlling the dataflow  Three wire SPI bus for communication between microcontroller and peripherals

8 Fig 3:Block scheme of hardware

9 It can be divisioned into four categories i. Data flow from CERBERUS element ii. Data flows from SENSORs element iii. Management data flow iv. Provisioning data flow

10 It includes mainly three biometric datas  Three channel ECG data with a data rate of 2400 Bps  Body and ambient temperature with data rate of 1/60Bps  Patient’s posture-measured by using two accelerometers and send at a rate of 2500 Bps Each of this data having it’s own ZigBee cluster ID

11 This is to measure the following datas  Heart rate  Blood pressure  Oxygen saturation  Body weight  Patient’s location in monitored space

12 All the biometric datas are send to CERBERUS element which is equipped with LCD display and keyboard.

13  It is used for the centralized administration of inner part of the system  It also indicate the error notification,specification of error,status of battery charge…  Inner part implementing the management by ZigBee logical links  Outer part uses SNMP technology for management

14  It provide initial settings for starting of ORTHRUS element  It exist only in outer part of biotelemetric system  It use DHCP and NTP technology to set TCP/IP protocol related settings

15  Now the model biotelemetric system is used for indoor application only  It using one to one mapping between the patient and zigbee network  The patient can be able to view the biometric data using LCD display.

16  Outdoor operation can be implemented using 3G mobile technology  With the advancement of low power,high density FPGA solutions the system become more reliable

17  Peterek, T., Žůrek, P., Augustynek, M., Penhaker, M. Global courseware for visualization and processing biosignals, WORLD CONGRESS 2009 - MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING  Cerny M., Penhaker M. Biotelemetry In conference proceedings 14 th Nordic-Baltic Conference an Biomedical Engineering and Medical Physics, JUN 16-20, 2008 Riga  Penhaker M., Cerny M., Martinak L., et al. HomeCare – Smart embedded biotelemetry systém In Book Series IFMBE proceedings World Congress on Medical Physics and Biomedical Engineering M. Penhaker, M. Cerny, M. Rosulek “Sensitivity Analysis and  Application of Transducers “ 5th International Summer School and Symposium on Medical Devices and Biosensors, JUN 01-03, 2008