Sept 2000E. Auffray, P. Lecoq, EP-CMA Results on the 100 R&D EndCap crystals measured in RCCERN on ACCOCE2 E. Auffray, P. Lecoq CERN EP-CMA
2
Sept 2000E. Auffray, P. Lecoq, EP-CMA We have received 100 polished Endcaps crystals in June2000 from Bogoroditsk: –all have been tested in CERN RC »Visual Inspection, »Characterised with ACCOCe2 : 1st operation of the 2nd Accos machine in CERN RC
3
Sept 2000E. Auffray, P. Lecoq, EP-CMA Longitudinal Transmission 360nm 420nm 620nm
4
Sept 2000E. Auffray, P. Lecoq, EP-CMA Longitudinal Transmission at 420nm 100 Endcaps Crystals Barrel Crystals Batch09
5
Sept 2000E. Auffray, P. Lecoq, EP-CMA Light Yield Barrel polished crystals from Batch09 Endcaps polished crystals
6
Sept 2000E. Auffray, P. Lecoq, EP-CMA Light Yield Non uniformity Barrel polished crystals from Batch09 Endcaps polished crystals FNUF
7
Sept 2000E. Auffray, P. Lecoq, EP-CMA Lateral Irradiation at saturation Barrel polished crystals from Batch09 Endcaps polished crystals
8
Sept 2000E. Auffray, P. Lecoq, EP-CMA Considerations about Endcap crystals After 2 years of R&D in Bogoroditsk –They have demonstrated that they can produce endcap crystals of similar quality than barrel crystals –Could be OK for at least 25% of endcap crystals –They have not yet achieved the rad. hardness specs for the most exposed endcap crystals