1
Presented By: FERHAN JAMAL ROLL NO - 0712231033 (E.C. Final Year) 1
2
2
3
Assembly shop SHOP 1 SHOP 2 SHOP 3 SHOP 4 ALH Manufacturing shop NGL Shop Smith Shop Gyro shop Press Shop 3
4
Basic Data Length15.87 m Main Rotor Diameter13.20 m Height4.91 mMax. Take-off Weight5500 kg Useful Load2600 kgCabin Fuel Capacity1100 kg Performance Cruising Speed250 km/ hr Max Never Exceed 295 km/h Oblique Rate of Climb620 m/min 4
5
AC Electrical Distribution Box DC Electrical Distribution Box Filter Transformer Unit ( FTU ) Alternator Control and Protection Unit (ACPU) Auxiliary Tank Probe Radio Magnetic Indicator 5
6
6
7
Distributes the complete dc power generation. It contains the main bus through which dc power is directed to the overhead panel through circuit breakers for dc power distribution. During normal operation, the total dc power from starter/generator is brought to the main bus through Normally Open (N.O.) contactor, which is controlled by GCPU. 7
8
Input sources for DC Master Box: Starter/generator along with GCPU: 6 KW Battery (Ni-Cd): 40 Ah External power source on ground: 6 KW Types of O/P Buses: Main Bus – 200 A at 28 V DC through 100 A circuit breaker: 1 no. 50 A circuit breaker: 2 no. 3 A circuit breaker: 2 no. 8
9
All grounding/reference lines are connected to a common negative point. The chassis of the unit is kept isolated from the grounding points. The bonding points are provided on the unit at the mounting points. Transient suppressors and free wheeling diodes are also used in PCB circuit design. The length of the leads/wires is kept as short as possible. 9
10
Over voltage protection test (in normal & environmental condition) Under voltage protection test (in normal & environmental condition) Over/Under frequency Vibration test Functional test 10
11
External Power Control (EPC) card housed inside the DC Master Box provides the following functions when external power is selected to the Helicopter. Over voltage protection: At 30.5 1 V with a fixed time delay of 0.4 0.1 sec. Reverse polarity protection: If the polarity of the external power is reversed. 11
12
Manual Mode: Corrected by appropriate design Partial Failure Mode: One Generator FAIL NE (Non Essential Bus OFF) Only TIE Bus ON- Gives Supply to essential parts ONLY. Emergency Mode: When Both Generators FAIL Emergency Landing( Within 15 TO 20 Minutes) 12
13
13
14
Functions: Rolling, Pitching & Yawing 14
15
GMC- Conservation of angular momentum Combination of electronics & mechanical portion Supply is 115v A.C. & 400 Hz 15
16
A gyroscope is a device for measuring or maintaining orientation 16
17
Five types of Gyroscopic Instrument: GA-2M-Gyro Unit BK53—Erection Cut off Switch 458K/458M-Gyro transmitter DK-3—Cone Position Transmitter 1122 B: 17
18
Rate of climb the rate of change of a barometric pressure static pressure is used Caliberated leak 18
19
19
20
Indicates the height of aircraft Visual reading on the front dial face Digitized signal to automatic altitude reporting devices 20
21
21