FPGA IRRADIATION @ NPTC-MGH (Part 1) Ray Mountain, Bin Gui, JC Wang, Marina Artuso Syracuse University
2
Outline NPTC Facility & Irradiation FPGA Setup Results: Hard Errors, SEU, etc. (limited) Post-Mortem Analysis (Failure Mode) Operational Experience with FPGA Summary & Plans R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/20102 THIS IS WORK IN PROGRESS !
3
NTPC Facility Northeast Proton Therapy Facility @ MGH – Cancer facility, Mass General Hospital, Boston MA Cyclotron: – 230 MeV p primary beam, Pb foil scatterer, collimating aperture – Gives 226 MeV (~2 x MIP) on target, essentially monochromatic, E bite <1% – Dosimetry: Calibration w/ ion chamber, Faraday cup, <10% absolute – Beam: 2.1e11 p/cm 2 s max, core 10 mm diam R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/20103
4
NPTC @ MGH R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/2010 ~ 230 MeV Protons 4 NEAR STATION FAR STATION FPGA Cyclotron
5
R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/20105 Louvain #00
6
Extraction and Beamline R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/20106
7
Patient Area (Gantry) R. Mountain, Syracuse University SU VELO Meeting, 8/24/20107
8
Test Beamline R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/20108
9
FPGA Setup (1) FPGA used: Actel ProASIC3 A3PE1500-PQ208 Our Setup: – FPGA on Eval PCB mounted in beamline, at 0 deg – AC Power on remote relay – Near station (PC, TNG DIO, XBD, etc.) shielded, Borated PE (n th ) LabVIEW for comm and control Actel Libero for config – Far station (remote LT connected to Near PC) – Laser alignment, proton radiochromatography (proton “x-ray”), webcam R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/20109
10
FPGA Setup (2) R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/201010 Aperture Ø12.7 mm Aperture Ø12.7 mm Ion Chamber FPGA Board p Beam Adjustable mechanics Adjustable mechanics
11
Near Station R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/201011 (Not manned during data-taking) B-PE shield Programmer B-PE shield B-PE shield Near PC
12
Irradiation (1) Irradiation – Dose up to 127 kRad(Si) – Fluence up to 3.9E9 p/cm 2 s @ 226.MeV – 226 MeV p = ~2 x MIP General Procedure for data- taking – Configure (if needed) – Set CLK freq – Clear/Start – Irradiate (wait for fixed dose in a given run) – Read out results R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/201012
13
Irradiation (2) Beam location – Centered on FPGA – Laser aligned, cross-checked with RCG image Beam uniformity – Adjust thin foil scatterer, 19 mm diam aperture – About 8% over central 8 mm FPGA die: 7.9 x 7.7 mm2 R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/201013 ~28 mm (pkg) Proton radiochromatograph ~8 mm (die) ~8 mm (die)
14
Results: Tests Planned Basic Operation * – Monitor if FPGA is still alive – Cycle power occasionally SEU * – Counter – Serial input to shift reg chain – Output from shift reg chain – Compare to original counter – If different, incr error count – (repeat @ various clk: 40, 120, 240 MHz) RAM – Counter – W counter to ram (3x) – R ram – Compare to original counter, using TVS – If different, incr error count – (repeat @ various clk) R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/201014 ROM – W rom with number (3x), using JTAG – R rom – Compare to original number, using TVS – If different, incr error count – (repeat @ various clk) CFG * – (Re-)configure FPGA periodically – Verify configuration Plan is to make all these measurements – For this first irradiation, those marked (*) were made – However SEU was a problematic case – Hard errors: full series
15
Results: TID & Hard Errors FPGA stopped responding somewhere >90 kRad – Specifically, failed during 2.9 min run with dose going from 89.9 to 127.0 kRad(Si), and fluence 3.92E+09 226.MeV p/cm 2 s Firmware failure – No response to communciations asking for readout of counter Plus configuration failure – Specifically, configuration failure code EXIT -24 (unstable vpump voltage levels), although vpump measured OK on PCB – Simple verification also failed Tried to recover in situ – Power cycle FPGA, restart control program, power cycle PCs, repeated configs, recompilation, swap programmer, etc. – No success, so declared it dead R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/201015 Our rough goal was: operational until 30 kRad – Expected rad levels were about 30 kRad/100.fb -1 – Note: other Actel A3P devices show adverse effects (propagation delay, frequency degradation) at doses >70 kRad
16
Post-Mortem Analysis Investigated a number of possibilities for FPGA failure mode – Timing, firmware – Hardware Most likely culprit: low Vcc – 1.5 V DC core device power level, with limits 1.425–1.575 V – LDO Reg on Eval PCB generates 1.510 V – But at FPGA measured Vcc ranges from 1.398 V down to 1.315 V – All Vcc at FPGA are below lower operational limit – Corresponding Vcc on unirradiated Eval PCB is 1.5 V (good) R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/201016 Caused by increased current draw in FPGA itself – Only traces between Reg and FPGA, no other resistive element – Estimate ~ 1 A draw (or more) – When FPGA removed from Eval PCB, all Vcc come back to 1.5 V – Increased Icc current sinking with dose is the behavior of RT54SX (antifuse device), spikes up >80 kRad Due to: gate rupture, latch-up? – Tracing down physical cause (SEGR, SEL) Recovery scheme? – Tried some different power routing: unstable Vcc after FPGA on for few seconds – Will try delivering independent completely off-board power – Annealing ? Will try this – Open to other suggestions
17
Results: SEU Test Problematic: – We had a large number of problems in Boston, mainly with timing and reproducibility (coding was a bit ambitious to begin) – Had to scale back tests and simplify code – Tried SEU test alone, no memory testing, no TVS – Retained 101010… input to shift register chain and bit-by-bit comparison, error counter, and communications blocks Results: – Result is hard to interpret, saw small number of error counts for all runs (0 or 1 for most), but not increasing in the expected way – Possible that we have residual timing problem, perhaps at comparator (under study), so we are making no statements about SEU rate from this data at this time – Have performed a series of systematic studies to understand what we saw. Still under investigation, in contact with Actel engineering on this problem R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/201017
18
Operational Experience Had a number of issues with this FPGA – Timing (old and new issues) – VHDL implementation suspect – Software interface, error reporting inadequate Need to do more testing to get reliable behavior – Really have to dig into it, check all critical signal lines, etc. – We were too ambitious for a first irradiation test Programmer problems – Many configuration failures in situ at NPTC (>30%); rare before and after at SU (~1%) – Recover by power cycle FPGA, rebooting PC, swapping programmers (repeatedly, or in combinations) – We had two programmers, both behaved badly – Maybe power was spiky at NTPC, or…? – Tremendous headache, caution about using FlashPRO3 in critical situation, it was very flaky Reliability and reproducibility – some problems here…We had difficulties in reproducing detailed behavior of firmware, especially with regard to timing and synchronicity issues R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/201018
19
Timing Issues Some systematic studies of timing – Use a small project, with counter, “firmware” delay (i.e., Actel module), and “writing” delay (VHDL code) – Set delay in code, measure delay on scope, get plot shown Timing changes when recompile but not reconfigure – Known (offsets in this plot) Timing delays using Actel module works, timing delays using VHDL block does not work at all – Simulates correctly, of course! – Syntactically-correct VHDL – Actel compiler didn’t flag this as an “error” for this FPGA – Really problematic, since Actel module is limited to ~7 ns delay Still have not fully sorted all timing issues R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/201019 device simulation
20
Conclusion & Plans FPGA functioned normally under irradiation by 226 MeV p until dose reached 90–127 kRad(Si) FPGA became unresponsive due to large current draw on the device (and consequently, a too-low Vcc) SEU test results were difficult to interpret, due in part to timing issues and other problems found in situ. Similar for memory tests. Will revisit these tests (esp. with input from Actel engineering) This FPGA seems to have a number of drawbacks, including timing and operational issues (and perhaps even VHDL implementation) We are continuing to refine the diagnostics on dead FPGA, to understand the mechanism and a possible recovery scheme Have established a baseline procedure for testing devices, including algorithm, communications, irradiation details, etc. Plan is to settle issues found and follow up with another irradiation test R. Mountain, Syracuse University LHCB Electronics Upgrade Meeting, 10/14/201020