Laser transient induced by a pumping step t Ip Case of HeNe : and c same order of magnitude n0n0 Laser intensity n th nn
2
Laser transient induced by a pumping step t Ip Case of Nd:YAG: >> c spiking =230µs c =22ns n0n0 Laser intensity n th nn
3
Zoom on the first spike
4
Laser transient induced by a pumping step t Ip Case of Nd:YAG: >> c spiking =230µs c =33ns relaxation oscillations n0n0 Laser intensity n th nn
5
n always in steady state 1/R 1 R 2 R 3 n0n0 Laser intensity n th nn In case of HeNe, approximation correct Comparison with hypothesis chapter 3
6
n always in steady state 1/R 1 R 2 R 3 In case of Nd:YAG, approximation not correct Comparison with hypothesis chapter 3
7
Q-switched regime E1E1 E2E2 Lower level Upper level E0E0 Fundamental level Amplifying medium Pumping Spontaneous emission Switch off Energy storage in the upper level Cavity blocked : high losses, no laser action
8
E1E1 E2E2 Lower level Upper level E0E0 Fundamental level Amplifying medium Pumping Switch on Q-switched regime Energy storage in the upper level Laser pulse
9
Q-switched regime E1E1 E2E2 Lower level Upper level E0E0 Fundamental level Amplifying medium Pumping Switch on Energy storage in the upper level Cavity draining
10
Q-switched regime and spiking