OPTIMUM DESIGN OF A HOUSE AND ITS HVAC SYSTEMS USING SIMULATION
BASED OPTIMISATION M.Hamdy A.Hasan K.Sirén Aalto University
2
Introduction buildings a major sector of energy consumption
continuously stricter energy directives demand for improved energy solutions in buildings OPTIMISATION of the building structures and HVAC systems
3
Case building two-floor semi-detached house total floor area 143 m2
room height 2.5 m mechanical ventilation + heat recovery air exchange rate 0.6 1/h initial design according to Finnish building code
5
Ground floor Upper floor
6
Design variables x1 insulation thickness, wall 40
x2 insulation thickness, roof 40 x3 insulation thickness, floor 40 x4 type of window 5 x5 building tightness 5 x6 type of heating (cooling) system 5 x7 type of heat recovery 3 x8 type of shading 2 Alternatives = 40x40x40x5x5x5x3x2 = 48 ∙106
7
Objective functions Problem definition F1 = Investment cost [€]
F2 = CO2 emissions of heating [kg/a] Problem definition Min [F1(x), F2(x)]; x = [x1, x2,…, x8]T;
8
New decision variables.
Start Tools Simulation: IDA-ICE Optimisation: Genetic Algorithm (MATLAB) Simulation IDA-ICE New decision variables. Energy CO2 PPD Optimisation MATLAB Investment LCC MinF(x)? no yes End
9
Investment cost € CO2 emissions (kg/a) 40000 35000 30000 25000 20000
15000 10000 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 CO2 emissions (kg/a)
10
Non-dominated solutions, no constraint
41
11
Indoor air temperature, point 41
12
Indoor air temperature, point 41
13
DH24 CONSTRAINT DH24 = S (Ti - 24) dt Ti - 24 > 0
8760 DH24 = S (Ti - 24) dt Ti - 24 > 0 Ti indoor air temperature during the hour i dt time increment (3600 s) i=1
14
Non-dominated solutions, DH24 constraint
Heat Pump + free cooling (sys 5) + Shading Heat Pump + free cooling (sys 5) District heat (sys 3) Heat Pump + free cooling (sys 5) Fuel boiler (sys 2) Ele. Rad (sys 1)
15
Conclusions the non-constrained optimisation finds 41 non- dominated solutions the electric radiator system and the heat-pump system are the extremes of the selection these solutions suffer from summer time overheating adding a DH24 constraint shifts the pareto front towards more expensive solutions setting DH24<1000 Chr selects heat-pump only