Advantages. Defense against enemy attack. Technology must work dependably. Lives depend on the technology, and execution in product.

Similar presentations


Presentation on theme: "Advantages. Defense against enemy attack. Technology must work dependably. Lives depend on the technology, and execution in product."— Presentation transcript:

1 Advantages

2 Defense against enemy attack. Technology must work dependably. Lives depend on the technology, and execution in product.

3 We ARE under attack from air pollution: VOC’s, bacteria, mold, and viruses. Lives and Health of people depend on our technology. We have a Strategic Air Defense System! Same Principals in Air Purification.

4 Broad spectrum UV lamp Quad-metallic Hydrophilic coating Photo Catalytic Oxidation (PCO) A Unique and proprietary PCO System Honeycomb Matrix for maximum surface area

5 ‘ s Photo Catalytic Oxidation Technology converts natural humidity and oxygen into Cluster Ions and oxides for air and surface sanitizing and purification, in concert with reduced ambient ozone. At the Heart of PCO is our Proprietary Patented Catalyst

6 0 OH OH- Broad Spectrum UV Light OH- H2O2H2O2 Cluster Ions H2O2H2O2 O2O2 Hydroxyls 0 OH HydroxidesOH- Super Oxides O 2 - Hydrogen Peroxide H 2 O 2 Ozonide Ions O 3 - Ozone O 3 Hydroxyls 0 OH HydroxidesOH- Super Oxides O2-O2-O2-O2- Hydrogen Peroxide H2O2H2O2H2O2H2O2 Ozonide Ions O3-O3-O3-O3-Ozone O3O3O3O3 The Photocatalytic Process

7 Oxidation Technology includes Low-Level Ozone Ozone reduces odors and VOC’s including mold, bacteria & virus. All outdoor environment have a low-level of ozone, typically 10-50 parts per billion Just like Oxygen & other naturally occurring elements Ozone is Dangerous at High Levels The last 40 years has shown that too low a level of ozone is also proving to be dangerous Ozone is proven to be effective even at low levels

8 Active Technology vs. Passive Technology ● Filtering ● Germicidal UV Lamps HVAC PROBE

9 Passive Technology Sucks the pollution through a filter - maybe… Filters Electrostatic Filters

10 Filters Electrostatic Filters Passive Technology Suck the pollution through a filter, maybe…. Can a filter SUCK BACTERIA from a COUNTER TOP? From a DoorKnob?

11 Passive Technology Big Electric Bill$ Does not Sanitize. Does not kill bacteria and viruses. Filter becomes a breeding ground for bacteria, mold, and dust mites. Disadvantages:

12 PASSIVE Germicidal UV Lights The goal is to get bacteria and viruses to the UV light. However, there are many IF’S influencing Germicidal UV effectiveness. IF you can get the pollutant to the UV light… IF the time exposure is long enough, there is questionable effectiveness. Inspired TEC is NOT PASSIVE Germicidal UV.

13 <<<<<TOO FAST! <<<<<TOO FAR AWAY!

14 Mold must be exposed for at least 3 seconds to UV at very close range to kill it. Mold passing by a UV light at a high rate of speed will not be destroyed allowing re-contamination of the breathing space. TOO FAST!>>>>>

15 DEN BR STUDY BR KITCHEN PCO unit A/C unit DEN BR STUDY BR KITCHEN UV unitA/C unit How do “UV bulbs” Compare to PCO ? Structure Using PCO Structure using “Germicidal UV” bulb Using UV bulb Control space 16,000 ft3 - - - - - - - - - - - - - - - - - 0.95 ft3 Microbe “kill” in entire structure 99.9% - - - - - - - - - - - - - - - - - - - -- - 2% Particulate control entire structure Yes - - - - - - - - - - - - - - - - - - - - - - No Odor control in entire structure Yes - - - - - -- - - - - - - - - - - - - - - - - No Technology Comparison

16 Cluster Ions send out purifying agents to destroy allergy causing mold, dangerous bacteria, viruses, and VOC’s in the air. 24 hrs. a day

17 Kills Germs on Surfaces like doorknobs, toilets, kitchen counters and cat litter boxes.

18 Inspired TEC Cluster Ions can tackle: Odors Smoke Pets Food

19 New Construction and renovation odors too! Paint Glue Plywood New Carpet Chemicals

20 -ly ACTIVE TECHNOLOGY is significantly more effective than PASSIVE TECHNOLOGY Filtering Germicidal UV Lamps

21 –Tested by the most highly respected labs in this industry. Kansas State University University of Cincinnati EMSL Inspired TEC Cluster Ions at work

22 Kansas State University Testing: ability of Unique Photocatalytic Device to Reduce Microbial Populations on Surfaces in 24 hours __________________________________________________________  Staph (Staphylococcus aureus) : 98.5% reduction  MRSA (Methycillin Resistant Staphylococcus aureus): 99.8% reduction  E-Coli (Escherichia coli) : 98.1% reduction  Anthrax family (Bacillus spp.) : 99.38% reduction  Strep (Streptococcus spp.) : 96.4% reduction  Pseudomonas aureuginosa : 99.0% reduction  Listeria monocytogenes : 99.75% reduction  Candida albicans : 99.92% reduction  Black Mold (Stachybotrys chartarum) : 99.93% reduction

23 Using Inspired TEC Cluster ION Technology

24 Ozone alone at 50 ppb PCO with Ozone below 20 ppb “PCO & O 3” Candida albicans & PCO Candida albicans & Ozone Stachybotrys & PCO Stachybotrys & Ozone Candida albicans & PCO Candida albicans & Ozone Stachybotrys & PCO Stachybotrys & Ozone

25 Avian Flu testing Dr. Jill Bieker - Sandia National Laboratory

26

27 78% Reduction of microbials with PCO THE POWER OF A HUMAN SNEEZE 3’ THE MESSAGE IS

28

29 Recent Application of Our Technology In A Retail Grocery Store

30 Inspired TEC Photocatalytic technology was deployed in a retail grocery store located in Eastern Ohio. Units were installed in the following areas: Produce display Cases Meat and Deli Cases Walk-in Produce, Deli, Meat, Bakery, Dairy Coolers Meat Cutting Room The store was a franchisee of a large regional chain and data was recorded over a 1 year period to determine the impact on several key indicators. The following results were obtained:

31 Test CriteriaPre Instillation Data Post Instillation Data (One year results) Shrink Percentage – Produce, FreshMeat & Deli 2.3%.Less than 1%. Customer PerceptionNo comments noted. Many unsolicited comments regarding the “ freshness ” of the store. Employee Perception Issues with odors in fresh meat/fish areas and in the walk-in cooler. Noticeable improvement, especially in the meat/fish areas. Maintenance Periodic cleaning of cooling coils. Frequency of cleaning reduced by 70%. Customer PerceptionNo comments noted. Perishable foods last longer. Recent Application of Our Technology In A Retail Grocery Store

32 Additional benefits are being evaluated which include: Reduced Employee sick time. Reduced chance of food born contamination (note this store has had no known pre PCO or post PCO food born contamination to date). The owner has stated he goes home not worrying about a food born incident as he would prior to installing the PCO Technology. At the 1st end of year review of costs, shrink savings and system benefits meeting, the store owner was quoted as saying: “Knowing what I paid and zero maintenance (one bulb replaced under warranty) and the amount of electricity used (not measureable), if an employee would leave the ceiling lights on one extra hour in the grocery department one time a year would be more electricity than this whole system used for the year. Again the knowledge of what I paid, the savings and benefits received; if you walked in here today quoting a price of double what I spent I would not hesitate to purchase this system”.

33 Recent Application of Our Technology In A Retail Grocery Store

34

35 New Store Construction VOC’s are worse in new construction. Glues in Plywood, and Veneer Paint, Flooring, New Fixtures. With Inspired TEC - Keep a new store mold free from the beginning. Get rid of strong chemical odors more quickly. Breathe with EASE. Inspired TEC Cluster Ions at work

36

37 Homestretch Enviroscreening Results With Pre & Post Swab Results

38 ●MAINTENANCE SALES NEWS ● PR PIECE FROM University of Louisville Testimonial letter

39 Triton Community Schools Bourbon, Indiana TESTIMONIAL

40

41 POKEGON HVAC INSTALLATION DRAWING

42 HEPA Hospital –Clean Room Particulate count/m3 measured @ 0.5 um Typical office 2 -3 million/m3 @ 0.5 um Before and After 2- 9” PCO Units in A/C ducts Loc Class Before/m3 After/m3 Imp % 01 5 1391.4 77.7 94% 02 5 692.2 21.2 97% 03 5 621.5 7.1 99% 04 5 374.3 7.1 98% 05 6 11,569.1 2,366.1 80% 06 6 22,236.5 332.0 99% 07 7 337,161.9 165,484.6 51% 08 7 249,121.4 153,887.2 38% 09 8 1,614,245.0 334,401.6 79% 10 8 1,304,842.0 373,078.3 71% 11 7 247,614.7 53,614.7 78% 12 7 203,518.4 50,302.2 75% All particle counts were taken in accordance with ISO 14644-1 standards Microbial Colonies - Before & After RCI Location Before After 1- 2 Horizontal Flow Clean Bench 0 0 3- 4 Horizontal Flow Clean Bench 0 0 5- 6 Main Clean Room 14 0 7- 8 Operating Room 9 0 9- 10 Hallway 27 8 11-12 Ante Room 23 15 12 3 4 5 6 10 11 12 Main Hallway Ante Room Main Clean Room 2822 f t3 8 9 Operating Room ~3200 ft3 std A/C 7 HEPA Sliding Window- normally open during procedures Supply Air Thru HEPA on ceiling Door Not Sealed Air Quality Survey – OB/GYN – IVF LAB

43 about Inspired TEC’s nature based technologies: 1. We clean air indoors like nature cleans the air outdoors using: a. Two types of Ionization to reduce particles b. UV and a Catalyst to create Cluster Ions and friendly oxidizers to reduce microbial contaminants (Photo Catalytic Oxidation) c. Low-level ozone to reduce odors 2. This is an ACTIVE cluster ion technology, not Passive 3. The only Air and Surface Purification with validation testing from multiple universities proving the ability to reduce up to 99.99% of Mold, Fungi, Bacteria and Viruses, including MRSA and Avian Bird Flu on surfaces and Most recently CRE. about Inspired TEC’s nature based technologies: 1. We clean air indoors like nature cleans the air outdoors using: a. Two types of Ionization to reduce particles b. UV and a Catalyst to create Cluster Ions and friendly oxidizers to reduce microbial contaminants (Photo Catalytic Oxidation) c. Low-level ozone to reduce odors 2. This is an ACTIVE cluster ion technology, not Passive 3. The only Air and Surface Purification with validation testing from multiple universities proving the ability to reduce up to 99.99% of Mold, Fungi, Bacteria and Viruses, including MRSA and Avian Bird Flu on surfaces and Most recently CRE.

44