Presentation is loading. Please wait.

Presentation is loading. Please wait.

The Engineered Solution

Similar presentations


Presentation on theme: "The Engineered Solution"— Presentation transcript:

1 The Engineered Solution
Voltage Optimisation The Engineered Solution

2 Presentation Content About SDC Industries Products and Services
What is Voltage Optimisation Why Voltage Optimisation The Technology The Evaluation Process Voltage Optimisation Products Finance Options Selection of Clients Memberships & Accreditations Q & A

3 About SDC Industries Established 1978, East Kilbride, Scotland
Experts in Power Quality and Energy Efficiency Solutions Design, Manufacture, Installation & Maintenance Multiple Vertical Markets, including: NHS Retail Hotels Quarries Education Manufacturing Government/Local Authority 1 stop shop. Same guys that build the units sometimes go to site and install them. Wide variety of clients.

4 Products and Services Voltage Optimisation Vario – Static
Vario Ultra – Variable Lightmaster (Downstream) Power Factor Correction HV/LV Electrical Distribution Equipment Solar Power (Photovoltaic – PV) 33KV Equipment for Wind Farms Power Quality Surveys Vario:Fixed ratio auto type transformer design. Ultra: Fully automated stabilised version. LM: Installing downstream, not just for lighting circuits. Harmonic Filtration Surge Suppression

5 253V 242V 207V 220V What is Voltage Optimisation?
Voltage Optimisation is the concept of reducing the incoming voltage from the grid to achieve the optimum voltage for your equipment. 253V Maximum level supplied by the grid 242V The average level supplied by the grid in UK 220V The optimum voltage for equipment efficiency 207V Minimum level supplied by the grid

6 Why Voltage Optimisation?
Improve Energy Efficiency Reduce kWh Consumption Reduce Electricity Costs Reduce Capital Expenditure Reduce Carbon Emissions

7 The Technology To evaluate the potential of installing VO, we identify the types of load on site and categorise: VOLTAGE DEPENDENT: An electrical device whose power consumption varies with the voltage being supplied to it VOLTAGE INDEPENDENT: An electrical device whose power demand, within it’s designed operating range, is independent of supply voltage

8 Voltage Dependent Loads
Discharge Lighting 240V Halogen Lighting Fluorescent Lighting Magnetic Ballasts Refrigeration Loads Chillers AHU’s Ventilation Systems (without invertors or VSD’s) Motors/Pumps (without invertors or VSD’S) Lifts/Escalators (without invertors or VSD’s) Savings will vary on these types of loads. Lighting will offer 2% reduction in kWh per 1% reduction in voltage, whereas motors may only offer somewhere between 0.8% - 2% per 1% reduction, depending on motor size, how heavily it is loaded. Basically smaller lightly loaded motors offer higher savings than larger motors. Manufacturing Machinery (without invertors or VSD’s)

9 Voltage Independent Loads
LV Lighting Electronically Controlled Lighting Any motor load with invertors or VSD’s Electric Heating IT Equipment Other electrical equipment

10 The Evaluation Process
To evaluate the effectiveness of VO, we require: Energy usage HHD or Electricity Bills Maximum Demand Kwh Rate, (pence per unit) From this, we can do a quick desk-top survey and to provide indicative quote.

11 Indicative Quote - Example

12 The Evaluation Process
If this is of interest, we will do a full site survey to: Log the Voltage over 7 days Survey the site for the load profile and installation From the information gathered, we would then provide a firm proposal detailing the size and type of equipment, together with relevant warranties, actual savings and guarantees.

13 Voltage Optimisation Products Unit Sizes range from 30KVA-3MVA
Vario STATIC Varmatic Voltage Optimiser™ for the Complete power supply Unit Sizes range from 30KVA-3MVA

14 Voltage Reduction Graph

15 Voltage Optimisation Products Unit Sizes range from 30KVA-3MVA
Vario Ultra VARIABLE Varmatic Voltage Optimiser™ for the COMPLETE INCOMING POWER SUPPLY Unit Sizes range from 30KVA-3MVA

16 Voltage Stabilisation Graph

17 Installed Voltage Optimisation Units
500KVA Vario Ultra 800KVA Vario Ultra 1500KVA Vario 500KVA Withenshaw, 800KVA Ipswich, 1500KVA Reta

18 Voltage Optimisation Products Unit Sizes range from 5KVA-150KVA
Varmatic Lightmaster Varmatic Voltage Optimiser™ for LIGHTING Unit Sizes range from 5KVA-150KVA Applications Car Park Lighting Factory Lighting Distribution Warehouses UL approved in USA, installed in Wynns Casino, if any of you have generous bosses that would pay for a jolly over there to inspect the unit, then the client would facilitate I think.

19 Examples of Installation
Method 1 Before Distribution Board Input power To lighting load Input power After Distribution Board To lighting load LIGHTMASTER

20 Examples of Installation
Method 2 Distribution Board Input power Mixed load After LIGHTMASTER Lighting load Input power Mixed load Distribution Board Before

21 Framework Agreements ESPO : Provide a procurement service for local authority, public and charitable sector customers in Eastern England. Available Nationwide. NHS Shared Business Services : is a procurement service for NHS trusts across England. London Procurement Partnership : is a procurement service for NHS trusts across London.

22 Finance Options Salix: 0% interest-free loans available to public sector bodies for projects under 5 years payback CEEF: 0% for Scottish public sector bodies Carbon Trust & Siemens: a joint partnership to provide UK businesses with green equipment finance at lower interest rates ACA: is a tax incentive for companies paying corporation tax and aims to encourage investment in energy efficient equipment. Through a choice of finance partners we can also offer hire purchase & operating lease finance options

23 Kelvin Industrial Estate
18 Colvilles Place Kelvin Industrial Estate East Kilbride United Kingdom G75 0PZ Tel: +44(0) Web:


Download ppt "The Engineered Solution"